Analisis Sensitivitas pada Penentuan Lokasi Gangguan Saluran Transmisi 500 kV Berbasis Gelombang Berjalan

Armando, Dwiki (2022) Analisis Sensitivitas pada Penentuan Lokasi Gangguan Saluran Transmisi 500 kV Berbasis Gelombang Berjalan. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 07111740000144-Undergraduate_Thesis.pdf] Text
07111740000144-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (4MB) | Request a copy

Abstract

Dengan berkembang pesatnya pemanfaatan tenaga listrik, maka jumlah dan jarak saluran transmisi ikut meningkat. Sebesar 85% sampai dengan 87% kegagalan pada sistem ketenagalistrikan timbul pada saluran transmisi. Oleh sebab itu saluran transmisi tidak luput dari berbagai macam gangguan yang bisa disebabkan oleh keadaan alam, kerusakan peralatan transmisi, dan kegagalan isolasi, bisa bersifat permanen maupun yang temporer atau sementara. Salah satu jenis gangguan yang kerap terjadi pada saluran transmisi adalah gangguan hubung singkat. Gangguan hubung singkat yang tidak segera diperbaiki akan mempengaruhi kualitas daya, dan keandalan sistem. Penentuan lokasi gangguan merupakan proses bertujuan mengidentifikasi gangguan yang terjadi pada saluran dengan tingkat ketepatan sebaik mungkin. Dengan menggunakan metode gelombang berjalan digunakan analisis frekuensi tinggi tegangan dan arus pada saluran transmisi. Gelombang berjalan merambat dari titik terjadinya gangguan ke kedua arah ujung saluran dengan kecepatan mendekati kecepatan cahaya. Ketika terjadi gangguan inilah tegangan dan arus akan mengalami lonjakan atau penurunan seketika. Perubahan secara tiba-tiba ini akan tercatat pada peralatan yang ada di gardu induk atau ujung – ujung dari sebuah saluran transmisi. Perhitungan estimasi lokasi gangguan secara umum dilakukan dengan menghitung selisih waktu tiba yang tercatat pada ujung – ujung saluran transmisi, kemudian dengan persamaan metode gelombang berjalan pasif dua terminal.
==============================================================================================================================
With the rapid development of electricity utilization, the number and distance of transmission lines have increased. Approximately 85% to 87% of failures in the electricity system occur in transmission lines. Therefore, transmission lines are not spared from various types of disturbances that can be caused by natural conditions, transmission equipment damage, and insulation failure, which can be permanent or temporary. One type of disturbance that often occurs on transmission lines is a short circuit. Short circuit disturbances that are not repaired immediately will affect power quality and system reliability. Fault location determination is a process aimed at identifying faults that occur in the line with the best possible level of accuracy. By using the traveling wave method, high-frequency voltage and current analysis are used on the transmission line. Traveling waves propagate from the point of the fault to both ends of the line at a speed approaching the speed of light. When a fault occurs, voltage and current experience an instantaneous surge or decrease. This sudden change will be recorded on equipment at the substation or at the ends of a transmission line. Fault location estimation calculations are generally performed by calculating the time difference of arrival recorded at the ends of the transmission line, then using the two-terminal passive traveling wave method equation.

Item Type: Thesis (Other)
Additional Information: RSE 621.319 Arm a-1 2022
Uncontrolled Keywords: Saluran transmisi 500 kV. Gelombang berjalan. Analisis sensitivitas. Penentuan lokasi gangguan. 500 kV transmission line. Traveling wave. Sensitivity analysis. Fault location determination.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering