Wahyudi, Firlan Arya (2022) Perbandingan Eksperimen Dan Simulasi Corona Discharge Negatif Menggunakan Elektroda Jarum-Plat Pada Isolasi Udara Berbasis Finite Element Method. Other thesis, Institut Teknologi Sepuluh Nopember.
|
Text
07111840000142-Undergraduate_Thesis.pdf Restricted to Repository staff only Download (2MB) |
Abstract
Fenomena corona merupakan fenomena yang sering diperhatikan karena adanya medan listrik yang tidak homogen. Terdapat dua jenis corona discharge berdasarkan arus pelepasannya yaitu corona discharge positif dan corona discharge negatif. Pada corona discharge negatif terjadi peristiwa pulsa trichel. Pulsa trichel merupakan pulsa yang unik yang memiliki amplitudo yang sama. Pada kenyataannya corona memiliki beberapa dampak yang sangat merugikan pada sistem transmisi tenaga listrik dan peralatan listrik karena memiliki frekuensi yang tinggi. Pada penelitian ini akan dilakukan penelitian tentang pengaruh tegangan terhadap arus puncak, arus rata-rata, dan frekuensi pada simulasi dan pengujian, dimana nilai yang didapatkan akan dilakukan perbandingan antara simulasi dan pengujian. Simulasi dilakukan menggunakan software berbasis Finite Element Method (FEM), sedangkan pada pengujian dibutuhkan pembangkit tegangan tinggi DC, akrilik chamber, konduktor, dan osiloskop. Pada akrilik chamber terdapat elektroda jarum-plat. Hasil simulasi dan pengujian menunjukkan bahwa semakin tinggi tegangan yang diterapkan, maka semakin tinggi juga arus puncak, arus rata-rata, dan frekuensinya. Selisih nilai arus puncak, arus rata-rata, dan frekuensi pada simulasi dan pengujian tidak signifikan. Hal ini dapat dilihat pada simulasi dengan tegangan -4,25 kV nilai arus puncaknya yaitu 0,10218 mA, nilai arus rata-ratanya yaitu 0,013905 mA, dan nilai frekuensinya yaitu 615,7635 kHz, sedangkan pada pengujian nilai arus puncaknya yaitu 0,088 mA, nilai arus rata-ratanya yaitu 0,009 mA, dan nilai frekuensinya yaitu 700,590 kHz. Kenaikan nilai pada arus puncak tidak signifikan ketika level tegangan dinaikkan. Hal ini dapat dilihat nilai arus puncak ketika tegangan dinaikkan pada simulasi dari -4,25 kV yaitu 0,10218 mA ke -4,5 kV yaitu 0,10658 mA, sedangkan pada pengujian dari -4,25 kV yaitu 0,088 mA ke -4,5 kV yaitu 0,092 mA.
==============================================================================================================================
Phenomenon corona is a phenomenon that is often noticed because of the inhomogeneous electric field. There are two types of corona discharges based on the discharge current, namely positive corona discharge and negative corona discharge. In negative corona discharge, a trichel pulse event occurs. Trichel pulses are unique pulses that have the same amplitude. In fact, the corona has some very detrimental impacts on the electric power transmission system and electrical equipment because it has a high frequency. In this study, research will be conducted on the effect of voltage on peak current, average current, and frequency in simulation and experiment, where the values obtained will be compared between simulation and experiment. The simulation is carried out using software based on Finite Element Method (FEM), while the experiment requires a DC high voltage test transformator, an acrylic chamber, a conductor, and an oscilloscope. In the acrylic chamber there is a needle-plane electrodes. The simulation and experiment results show that the higher the applied voltage, the higher the peak current, average current, and frequency. The difference between peak current, average current, and frequency in simulation and experiment is not significant. This can be seen in the simulation with a voltage of -4.25 kV, the peak current value is 0.10218 mA, the average current value is 0.013905 mA, and the frequency value is 615.7635 kHz, while in testing the peak current value is 0.088 mA, the average current value is 0.009 mA, and the frequency value is 700.590 kHz. The increase in the value of the peak current is not significant when the voltage level is increased. It can be seen that the peak current value when the voltage increased in the simulation from -4.25 kV is 0.10218 mA to -4.5 kV is 0.10658 mA, while in the experiment from -4.25 kV is 0.088 mA to -4.5 kV is 0.092 mA.
| Item Type: | Thesis (Other) |
|---|---|
| Additional Information: | RSE 537.52 Wah p-1 2022 |
| Uncontrolled Keywords: | Corona discharge. Pulsa trichel. Finite element method. Tegangan tinggi DC. Elektroda jarum-plat. |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
| Divisions: | Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis |
| Depositing User: | Mr. Marsudiyana - |
| Date Deposited: | 12 Jun 2026 08:32 |
| Last Modified: | 12 Jun 2026 08:32 |
| URI: | http://repository.its.ac.id/id/eprint/133780 |