Analisis Pengaruh Kedip Tegangan Pada Kinerja Kompresor Udara Di Pabrik Oksigen

Ma'mun, Muhammad Ainul Yaqin (2022) Analisis Pengaruh Kedip Tegangan Pada Kinerja Kompresor Udara Di Pabrik Oksigen. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 07111840000154-Undergraduate_Thesis.pdf] Text
07111840000154-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (2MB)

Abstract

Kompresor udara termasuk peralatan industri yang banyak digunakan untuk menaikkan tekanan udara. Kompresor udara memiliki beberapa penggerak salah satunya adalah motor induksi. Motor induksi sebagai penggerak kompresor membutuhkan sumber tenaga listrik dari jaringan. Penggunaan motor induksi pada sistem tenaga listrik memiliki beberapa keunggulan seperti konstruksinya yang kokoh, harganya relatif murah, mudah dalam melakukan perawatan, dan dapat diproduksi dengan karakteristik yang sesuai dengan kebutuhan industri. Meski begitu, pada sistem tenaga listrik dapat terjadi gangguan kedip tegangan yang dapat menyebabkan kerusakan pada kompresor. Dalam tugas akhir ini analisis akan dilakukan pada pabrik oksigen. Tugas akhir ini akan menganalisis kedip tegangan pada kinerja kompresor udara pada pabrik oksigen. Metode yang digunakan dalam tugas akhir ini untuk menyimulasikan kedip tegangan adalah gangguan hubung singkat 3 fasa pada Fault Bus. Berdasarkan hasil simulasi ini, dapat disimpulkan bahwa gangguan kedip tegangan yang terjadi di motor pada sistem kelistrikan dapat menyebabkan turunnya laju volume kompresor. Dari 3 studi kasus yang disimulasikan dalam kedip tegangan, didapatkan nilai dan durasi kedip tegangan pada sisi Bus GI PLN secara berurutan pada tiga studi kasus yaitu 43% 570 ms, 64% 1s, dan 79% 1s. Sedangkan pada sisi motor terjadi kedip tegangan sebesar 37% 570ms, 56% 1s, dan 75% 1s. Kedalaman dan durasi dari gangguan kedip tegangan dapat mempengaruhi kejadian trip atau tidak trip pada sistem proteksi elektrikal(UVR) dan proteksi mekanikal.
==============================================================================================================================
Air compressors include industrial equipment that is widely used to increase air pressure. Air compressors have several drives, one of which is an induction motor. The induction motor as a compressor drive requires an electric power source from the network. The use of induction motors in electric power systems has several advantages such as sturdy construction, relatively cheap prices, easy to maintain, and can be produced with characteristics that suit industrial needs. However, in the power system there can be a voltage dips that can cause a compressor failure. In this final project the analysis will be carried out on an oxygen plant. This final project will analyze the voltage dips on the performance of the air compressor in an oxygen plant. The method used in this final project to simulate voltage dips is 3-phase short circuit fault on the Fault Bus.Based on the results of this simulation, it can be concluded that voltage dips disturbances that occur in the motor in the electrical system can cause a decrease in the compressor flow rate. From the 3 case studies that were simulated in the voltage dips, magnitude and duration of the voltage dips on the Bus GI PLN side were obtained sequentially in the three case studies, that is 43% 570 ms, 64% 1s, and 79% 1s. While on the motor side there is a voltage dips of 37% 570ms, 56% 1s, and 75% 1s. The depth and duration of the voltage dips can affect the trip or non-trip occurrence of electrical protection (UVR) and mechanical protection systems

Item Type: Thesis (Other)
Additional Information: RSE 621.51 Mam a-1 2022
Uncontrolled Keywords: Kedip tegangan. Kompresor. Motor induksi. Compressor. Induction motor. Voltage dips.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis