Assessment Proteksi Transmisi Untuk Keandalan Ketenagalistrikan Di Kalimantan

Saputra, Ervin (2022) Assessment Proteksi Transmisi Untuk Keandalan Ketenagalistrikan Di Kalimantan. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 6032202066-Master_Thesis.pdf] Text
6032202066-Master_Thesis.pdf
Restricted to Repository staff only

Download (13MB) | Request a copy

Abstract

PT PLN (Persero) adalah perusahaan Badan Usaha Milik Negara yang bergerak pada bidang ketenagalistrikan. PT PLN dibagi ke dalam beberapa unit, salah satunya Unit Induk Pembangkitan dan Penyaluran Kalimantan (UIKL KAL) yang mengelola Pembangkitan dan Penyaluran di Kalimantan. Konfigurasi transmisi saluran udara yang panjang membentang dari Kalimantan Utara, Kalimantan Timur, Kalimantan Selatan, Kalimantan Tengah hingga Kalimantan barat dengan topografi hutan bukit dan jurang memiliki risiko tinggi terjadinya gangguan yang menyebabkan kerugian besar baik bagi PLN maupun pelanggan. Pemeliharaan periodik dan korektif telah di lakukan sesuai prosedur yang ada namun kegagalan fungsi proteksi untuk melokalisir gangguan tersebut masih sering terulang bahkan masih menyebabkan padam meluas dan lama. Maka diperlukan identifikasi penyebab gangguan transmisi yang sering dan berdampak besar serta diperlukan metode baru yang lebih baik, efisien dan efektif pada Asesmen Proteksi Transmisi dalam memastikan kesiapan fungsi proteksi untuk meningkatkan keandalan dan kinerja PT PLN UIKL KAL. Penelitian ini bertujuan untuk menemukan perbaikan metode asesmen dan pemeliharaan peralatan sistem proteksi saluran transmisi yang lebih baik lagi agar potensi gangguan yang ada bisa di eliminasi dan jika gangguan tetap terjadi maka fungsi proteksi mampu melokalisir dan mencegah padam meluas serta mempercepat proses pemulihan dan bahkan jika fungsi proteksi masih gagal melokalisir gangguan, maka proses recovery nya bisa di lakukan lebih cepat. Metode yang akan digunakan adalah Reliability Index Assessment untuk mengukur keandalan sistem proteksi transmisi dan menggunakan metode korelasi serta Regresi Linier Berganda serta Fault Tree Analysis untuk mendapatkan potensi risiko gangguan apa saja yang bisa di eliminasi dan pemeriksaan serta perbaikan apa saja yang diperlukan untuk memastikan kesiapan fungsi proteksi bay line yang bisa memaksimalkan peningkatan keandalan sistem proteksi transmisi. Diperoleh korelasi yang kuat untuk jenis gangguan petir, layang-layang dan pohon terhadap kinerja Auto Reclose Index, dan gangguan pohon menyebabkan kinerja ARI rendah sedangkan gangguan petir dan layang-layang menyebabkan kinerja ARI tinggi, sehingga ada potensi peningkatan kinerja auto reclose untuk gangguan oleh petir dan layang-layang.
==============================================================================================================================
PT PLN (Persero) is a State-Owned Enterprise that is engaged in the electricity sector. PT PLN is divided into several units, one of which is the Kalimantan Main Generation and Transmission Unit (UIKL KAL) which manages the Generation and Transmission in Kalimantan. The transmission configuration of the long overhead line stretching from North, East, South, and Cand central to West Kalimantan with forest topography of hills and ravines has a high risk of disturbances causing huge losses for both PLN and customers. Periodic and corrective maintenance has been carried out according to existing procedures, but the failure of the protection function to localize these disturbances is still frequent and even causes widespread and prolonged outages, so it is necessary to identify the causes of frequent and large-impact transmission disturbances and a new method that is better, more efficient is needed. and effective in the Transmission Protection Assessment in ensuring the readiness of the protection function to improve the reliability and performance of PT PLN UIKL KAL. This study aims to find an improvement in the assessment and maintenance method of transmission line protection system equipment that is even better so that the potential for existing disturbances can be eliminated and if the disturbance persists then the protection function to localize and prevent widespread outages and accelerate the recovery process and even if the protection function still fails to localize the disturbance, then the recovery process can be done faster. The method that will be used is Reliability Index Assessment to measure the reliability of the transmission protection system and use the Multiple Linear Regression method and Fault Tree Analysis to obtain any potential disturbance risks that can be eliminated and what inspections and repairs are needed to ensure the readiness of the bay line protection function that can maximize increased reliability of the transmission protection system. There is a strong correlation between lightning, kites, and tree disturbances on the Auto Reclose Index performance, and tree disturbances cause low ARI performance while lightning and kite disturbances cause high ARI performance, so there is a potential for increased auto reclose performance for lightning disturbances and kites.

Item Type: Thesis (Masters)
Additional Information: RTMT 620.004 52 Sap a-1 2022
Uncontrolled Keywords: Asesmen, Keandalan, Transmisi, Regresi, Fault Tree Analysis. Assessment, Reliability, Transmission, Regression, Fault Tree Analysis.
Subjects: T Technology > T Technology (General)
Divisions: Interdisciplinary School of Management and Technology (SIMT) > 61101-Master of Technology Management (MMT)
Depositing User: Mr. Marsudiyana -
Date Deposited: 09 Jul 2026 03:57
Last Modified: 09 Jul 2026 03:57
URI: http://repository.its.ac.id/id/eprint/134570