Alternatif Desain Struktur Dengan Base Isolation : High-Damping Rubber Bearing (Hdrb) Pada Struktur Bangunan Gedung Apartemen Nayumi Sam Tower Malang

Arifa, Geralda Nurry (2022) Alternatif Desain Struktur Dengan Base Isolation : High-Damping Rubber Bearing (Hdrb) Pada Struktur Bangunan Gedung Apartemen Nayumi Sam Tower Malang. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 10111810013014-Undergraduate_Thesis.pdf] Text
10111810013014-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (11MB) | Request a copy

Abstract

Struktur eksisting Apartemen Nayumi Sam Tower Malang merupakan Gedung Apartemen Nayumi Sam Tower yang berlokasi di Malang. Gedung Apartemen Nayumi Sam Tower merupakan gedung beton bertulang 10 lantai dengan struktur sistem ganda, yaitu Sistem Tahan Momen Khusus (SRPMK) dan dinding geser dengan pondasi raft. Perencanaan dengan sistem konvensional dengan dinding geser (shear wall) menyebabkan gedung eksisting mengalami collapse atau keruntuhan dan perbedaan simpangan yang tidak beraturan apabila terjadi gempa besar sesuai rencana perhitungan respons sektrum. Sehingga diperlukannya suatu pendekatan alternatif desain yang perlu diterapkan pada bangunan bertingkat. Salah satu cara yang efisien adalah dengan meredam energi gempa yang bekerja pada bangunan sampai ke tingkat yang tidak membahayakan yaitu dengan base isolator. Tahapan perencanaan dengan base isolation ini melalui 3 tahap permodelan struktur, yaitu tahap 1 permodelan kondisi eksisting bangunan dual system dengan sistem struktur SRPMK dan shear wall, tahap 2 permodelan sistem struktur SRPMB tanpa shear wall, dan tahap 3 adalah permodelan SRPMB dengan HDRB. Tahap 1 dan 2 pembebanan gempa yang digunakan adalah pembebanan respons spektrum, sedangkan pada tahap 3 pembebanan gempa dilakukan perhitungan pembebanan gempa respons spektrum kompsit akibat penggunaan base isolator. Permodelan dengan 3 tahap kemudian dilakukan analisa kontrol struktur sesuai standar perencanaan yaitu: simpangan antar lantai, gaya geser dasar, partisipasi massa, dan perioda fundamental. Tahap selanjutnya adalah perhitungan struktur atas dan bawah sehingga dapat dilakukan perbandingan penggunaan struktur HDRB dibandingan dengan struktur dual system. Hasil perhitungan alternatif desain pada Gedung Apartemen Nayumi Sam Tower dengan menggunakan base isolation: High Dumping Rubber Bearing (HDRB) dengan Sistem Rangka Penahan Momen Biasa (SRPMB). Penggunaan sistem base isolation tipe High-Dumping Rubber Bearing (HDRB) dapat mereduksi beban gempa yang diterima oleh gedung sebesar 24%, sehingga kapasitas akan berpengaruh dengan gaya dalam dan kapasitas dari elemen struktur. Hasil analisis perencanaan struktur dengan HDRB didapatkan perbedaan perbedaan nilai kontrol struktur dan kebutuhan tulangan maupun volume beton pada elemen struktur. Proyek akhir ini mendapatkan gaya geser dasar sebesar 9454.57 kN untuk arah X dan 10351.95 kN untuk arah Y. Gaya geser ini telah tereduksi sebesar 50.2% arah X dan 45.4 % ii arah Y dengan nilai gaya geser struktur fixed base adalah sebesar 18967.28 kN untuk arah X dan 18966.68 kN untuk arah Y. Gedung modifikasi dengan base isolation mengalami penghematan pada volume beton bertulang yaitu pada kebutuhan volume beton pilecap sebesar 37% dengan perbandingan volume beton eksisting adalah 437.86 m3 , bangunan modifikasi sebesar 276.93 mm3 . Kebutuhan tulangan eksisting (balok, kolom, dan pilecap) sebesar 8.72 mm2 , sedangkan kebutuhan tulangan bangunan modifikasi adalah 5.78 mm2 , sehingga didapatkan reduksi keseluruhan tulangan adalah 34%.
==============================================================================================================================
The existing structure of the Nayumi Sam Tower Apartment in Malang is the Nayumi Sam Tower Apartment Building which is located in Malang. Nayumi Sam Tower Apartment Building is a 10-story reinforced concrete building with a dual system structure, namely the Special Moment Resistant System (SRPMK) and a shear wall with a raft foundation. Planning with a conventional system with shear walls causes the existing building to collapse or collapse and irregular deviation differences in the event of a large earthquake according to the plan for calculating the response of the sector. So we need an alternative design approach that needs to be applied to high-rise buildings. One efficient way is to reduce the earthquake energy acting on the building to a level that is not dangerous, namely by using a base isolator. The planning stage with base isolation goes through 3 stages of structural modeling, namely stage 1 modeling the existing condition of a dual system with SRPMK and shear wall systems, stage 2 modeling the SRPMB structural system without shear walls, and stage 3 is SRPMB modeling with HDRB. Stages 1 and 2 of the earthquake loading used are spectrum response loads, while in stage 3 earthquake loading calculations are carried out on the calculation of the seismic loading of the composite response spectrum due to the use of a base isolator. The modeling with 3 stages is then analyzed for structural control according to the planning standards, namely: inter-floor drift, base shear force, mass participation, and fundamental period. The next stage is the calculation of the upper and lower structures so that a comparison of the use of the HRB structure can be made compared to the dual system. The results of the calculation of alternative designs on the Nayumi Sam Tower Apartment Building by using base isolation: High Dumping Rubber Bearing (HDRB) with Ordinary Moment Retaining Frame System (SRPMB). The use of a base isolation system of the High- Dumping Rubber Bearing (HDRB) type can reduce the earthquake load received by the building by 24%, so that the capacity will affect the internal forces and the capacity of the structural elements. The results of the analysis of structural planning with HDRB obtained differences in the value of structural control and the need for reinforcement as well as the volume of concrete in the structural elements. This final project gets a base shear force of iv 9454.57 kN for the X direction and 10351.95 kN for the Y direction. This shear force has been reduced by 50.2% in the X direction and 45.4% in the Y direction with the value of the shear force of the fixed base is 18967.28 kN for the X and X directions. 18966.68 kN for the Y direction. The modified building with base isolation experienced savings in the volume of reinforced concrete, namely the pilecap concrete volume requirement of 37% with the ratio of the existing concrete volume being 437.86 m3 , the modified building was 276.93 mm3 . The need for existing reinforcement (beams, columns, and pilecaps) is 8.72 mm2 , while the need for reinforcement for modified buildings is 5.78 mm2 , so that the overall reinforcement reduction is 34%.

Item Type: Thesis (Diploma)
Additional Information: RSIS 624.177 1 Ari a-1 2022
Uncontrolled Keywords: Base isolation, HDRB, Respons Spektrum, , Sistem Rangka Pemikul Momen Biasa, Sistem Rangka Pemikul Momen Khusus. Base isolation, HDRB, Response Spectrum, , Ordinary Moment Resistant Frame System, Special Moment Resistant Frame System
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Faculty of Vocational > 22301-Civil Infrastructure Engineering (D4)
Depositing User: Mr. Marsudiyana -
Date Deposited: 13 Jul 2026 08:19
Last Modified: 13 Jul 2026 08:19
URI: http://repository.its.ac.id/id/eprint/134811

Actions (login required)