Sistem Kontrol Pengaman Untuk Switchgear Terhadap Simulasi Gangguan Short Circuit Menggunakan Protokolmodbus Dengan Metode Network Control

Prasetyo, Septian Yudhistira (2022) Sistem Kontrol Pengaman Untuk Switchgear Terhadap Simulasi Gangguan Short Circuit Menggunakan Protokolmodbus Dengan Metode Network Control. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 10311810000033-Undergraduate_Thesis.pdf] Text
10311810000033-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (4MB)

Abstract

Sistem proteksi pada proses penyaluran listrik sangat diperlukan untuk menunjang kelancaran kebutuhan tenaga listrik sehari-hari sehingga membutuhkan tenaga listrik yang memadai dengan jumlah yang cukup serta andal sehingga terjaga kestabilan mutu dalam penyaluran guna meminimalisir dan mencegah terjadinya kendala dan gangguan yang menyebabkan kegagalan penyaluran pada line bay. Prototype perangkat komunikasi kontrol dan monitor secara nirkabel berperan sebagai perangkat untuk kendali dan pemantauan agar penanganan dapat dilakukan secara cepat untuk menjaga perlindungan perangkat line bay GIS Blimbing Baru 150 kV sehingga dapat menghindari penghambatan dalam menjalankan operasional Gardu Induk. Prototype didesain agar dapat melakukan kontrol dan monitoring perangkat switchgear pada line bay secara remote dengan memanfaatkan Bay Control Unit sebagai kontrol switchgear-nya melalui setting relay pada Relay Protection & Control Panel (RCP). Hal ini difungsikan agar ketika pada saat terjadi gangguan, kontrol digunakan untuk mengaktifkan kembali circuit breaker secara remote guna meningkatkan efisiensi kelancaran distribusi tenaga listrik. Tujuan dari penelitian ini yaitu untuk memberikan tambahan sistem kontrol yang berguna dalam memantau dan memberi perintah kendali kepada perangkat switchgear pada line bay dengan menggunakan metode Network Control yang berfungsi untuk mengetahui keterlambatan respon waktu oleh pengiriman data, penerimaan data dan menemukan data report yang hilang. Hasil dari penelitian ini menunjukkan bahwa rerata delay yang telah dikalkulasikan menggunakan Metode Network Control yaitu sebanyak 2 detik pada relay status, 8 detik pada dashboard status, dan sebanyak 5 detik pada data log status Wise-PaaS Dashboard, serta lamanya pengiriman data monitor dan kontrol bergantung pada kecepatan jaringan internet yang digunakan dan faktor-faktor penghambat pengiriman data lainnya.
==============================================================================================================================
A protection system in the electricity distribution process is very necessary to support the smooth running of daily electricity needs so that it requires adequate electricity in sufficient and reliable quantities so that quality stability in distribution is maintained in order to minimize and prevent the occurrence of obstacles and disturbances that cause distribution failures in the line bay. The prototype of the wireless control and monitor communication device acts as a device for control and monitoring so that handling can be carried out quickly to maintain the protection of the 150 kV Blimbing Baru GIS line bay device so as to avoid obstacles in carrying out the operations of the substation. The prototype is designed to be able to remotely control and monitor switchgear devices in the line bay by utilizing the Bay Control Unit as a switchgear control through the relay settings in the Relay Protection & Control Panel (RCP). This is enabled so that when a disturbance occurs, the control is used to reactivate the circuit breaker remotely in order to increase the efficiency of the smooth distribution of electricity. The purpose of this study is to provide an additional control system that is useful in monitoring and giving control commands to switchgear devices in the line bay by using the Network Control method which functions to determine the response time delay by sending data, receiving data and finding missing data reports. The results of this study indicate that the average delay that has been calculated using the Network Control method is 2 seconds on the relay status, 8 seconds on the dashboard status, and as much as 5 seconds on the Wise-PaaS Dashboard log data status, as well as the duration of sending monitor and control data. Depending on the speed of the internet network used and other data transmission inhibiting factors.

Item Type: Thesis (Diploma)
Additional Information: RSEO 629.89 Pra s-1 2022
Uncontrolled Keywords: SCADA, Substation Automation System, Internet of Things, Line Bay.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3070 Automatic control
Divisions: Faculty of Vocational > 36304-Automation Electronic Engineering
Depositing User: Mr. Marsudiyana -
Date Deposited: 15 Jul 2026 07:09
Last Modified: 15 Jul 2026 07:09
URI: http://repository.its.ac.id/id/eprint/135069

Actions (login required)

View Item View Item