Nugraha, Annisa Intania (2022) Sistem Pengaturan Kecepatan Motor Induksi 3 Phasa Berbeban Pada Remote Laboratory Menggunakan Webaccess Dengan Metode V/F Control Dalam Jaringan. Diploma thesis, Institut Teknologi Sepuluh Nopember.
|
Text
10311810003013-Undergraduate_Thesis.pdf Restricted to Repository staff only Download (4MB) |
Abstract
Pembelajaran mata kuliah mesin listrik dilengkapi dengan praktikum untuk menambah pemahaman mengenai materi yang disampaikan serta membentuk hardskill para mahasiswa. Namun dikarenakan adanya pandemi covid, praktikum tidak bisa lagi dilaksanakan karena seluruh pembelajaran dialihkan menjadi secara daring untuk menghindari peyebaran virus covid dan kontak langsung antar mahasiswa. Sebelumnya praktikum hanya bisa dilakukan apabila berada pada lokasi yang sama, jika dilihat dengan kondisi sekarang ini menjadi penghambat diadakannya praktikum. Remote laboratory merupakan implementasi dari Internet of Things (IoT). Remote laboratory ini memungkinkan terjadinya pengaksesan peralatan laboratorium melalui sebuah tampilan yang terdapat pada layar laptop masing-masing mahasiswa, selama terhubung dengan sebuah jaringan. Untuk mengatasi permasalahan tersebut, dibuatlah sebuah modul praktikum yang dapat diakses secara jarak jauh untuk praktikum mengubah kecepatan motor induksi 3 phasa dan pembebanan motor induksi 3 phasa. Dengan metode v/f control dalam jaringan kecepatan motor dapat diatur secara jarak jauh melalui jaringan menggunakan tampilan dashboard WebAccess. Untuk mengatur kecepatan pada motor induksi 3 phasa digunakanlah metode v/f control dengan mengubah frekuensi serta tegangan pada motor. Dari hasil kerja modul praktikum pada Remote Laboratory dengan metode v/f control ini didapatkan hasil bahwa pada pengujian kecepatan motor induksi 3 phasa, frekuensi berbanding lurus dengan RPM motor yaitu semakin besar frekuensi semakin besar pula kecepatan motor, begitu pula dengan tegangan dan frekuensi yang diberikan pada motor berbanding lurus, dengan frekuensi maksimal 50 Hz maka kecepatan yang dihasilkan motor 1496 RPM. Pada pengujian kecepatan motor induksi 3 phasa berbeban, kecepatan motor mengalami penurunan, karena beban semakin besar maka kecepatan motor semakin menurun. Pengiriman data metode v/f control melalui jaringan pada pengujian controlling memiliki rata- rata delay selama 1-2 detik dan pada pengujian monitoring memiliki rata-rata delay selama 47 detik serta selama proses pengujian tidak ditemukan Packet Dropout atau paket data hilang ditengah jalan.
==============================================================================================================================
The learning of electrical machinery courses is equipped with practicums to increase understanding of the material presented and form students' hard skills. However, due to the covid pandemic, the practicum can no longer be carried out because all learning has been shifted to online to avoid the spread of the covid virus and direct contact between students. Previously, the practicum could only be done if it was in the same location, if viewed with the current conditions, it became an obstacle to holding the practicum. Remote laboratory is an implementation of the Internet of Things (IoT). This remote laboratory allows access to laboratory equipment through a display on the laptop screen of each student, as long as it is connected to a network. To overcome this problem, a practicum module that can be accessed remotely for practicum changes the speed of a 3-phase induction motor and the loading of a 3- phase induction motor. With the v/f control method in the network, the motor speed can be set remotely over the network using the WebAccess dashboard display. To regulate the speed of a 3-phase induction motor, the v/f control method is used by changing the frequency and voltage of the motor. From the work of the practicum module at the Remote Laboratory with the v/f control method, it was found that in testing the speed of a 3-phase induction motor, the frequency is directly proportional to the RPM of the motor. The greater the frequency, the greater the motor speed, as well as the voltage and frequency given. on the motor is directly proportional, with a maximum frequency of 50 Hz, the resulting speed of the motor is 1496 RPM. In testing the speed of a 3-phase induction motor with a load, the motor speed is inversely proportional to the motor load, the greater the load, the lower the motor speed. Sending data via the v/f control method through the network in the controlling test has an average delay of 1-2 seconds and the monitoring test has an average delay of 47 seconds and during the testing process there were no Packet Dropouts or data packets lost in the middle of the road.
| Item Type: | Thesis (Diploma) |
|---|---|
| Additional Information: | RSEO 629.8 Nug s-1 2022 |
| Uncontrolled Keywords: | Beban, Kecepatan, Motor induksi, Praktikum daring, V/F Control. Load, Speed, Induction motor, Practicum online, V/F Control, |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3070 Automatic control |
| Divisions: | Faculty of Vocational > 36304-Automation Electronic Engineering |
| Depositing User: | Mr. Marsudiyana - |
| Date Deposited: | 16 Jul 2026 01:58 |
| Last Modified: | 16 Jul 2026 01:58 |
| URI: | http://repository.its.ac.id/id/eprint/135157 |
Actions (login required)
![]() |
View Item |