Sistem Kontrol Tekanan Pada Pompa Air Sentrifugal Cooling Tower Menggunakan Metode Pid

Budiprayitno, Slamet (2022) Sistem Kontrol Tekanan Pada Pompa Air Sentrifugal Cooling Tower Menggunakan Metode Pid. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 10311810003020-Undergraduate_Thesis.pdf] Text
10311810003020-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (6MB) | Request a copy

Abstract

PT. INDOLAKTO - Pandaan merupakan salah satu Industri yang bergerak dalam bidang pengolahan susu (dairy manufacturing). Produk yang dihasilkan PT. Indolakto Factory Pandaan adalah Susu Cair Indomilk (SCI). PT. INDOLAKTO memiliki kebutuhan Energi Listrik yang cukup besar tiap mesinnya pada saat Produksi. Salah satunya terdapat Sistem mesin Cooling Tower dimana terdapat 3 Mesin Cooling Tower dan 3 Pompa Air Sentrifugal serta adanya Ground Tank/ Kolam yang berisi Air Cooling Tower. Dimana Sistem mesin Cooling Tower Itu masuk ke dalam Peringkat kebutuhan energi yang terbesar ke-3 dari mesin yanglain di PT. INDOLAKTO. Pada Mesin Cooling Tower, terdapat 3 Pompa Air Sentrifugal ini berguna untuk Mendistribusikan/mensuplai Air dari Kolam Air Cooling Tower Menuju Mesin-mesin Produksi seperti; Mesin Pasteurisasi, Mesin Chiller, Mesin Auto Clave, dll yang berguna untuk Sistem Pendinginan. Kebutuhan Energi yang besar disebabkan 3 Pompa Air Sentrifugal, Pompa Air Sentrifugal ini bekerja secara Manual yang terus-menerus tiap waktunya dengan kecepatan tinggi (2100rpm) pada 3 Pompa Air Sentrifugal dengan kondisi Tekanan 2.8 Bar – 3 Bar Pada Pressure Gauge. Dimana Ketika Mesin Produksi tidak Membutuhkan Airyang besar pada Cooling Tower untuk sistem pendinginan, namun Pompa AirSelama ini Berkerja Secara Manual dan Terus-Menerus yang dinilai Kurang Efisien yang dapat menaikkan Konsumsi Energi Listrik, sehingga dapat mengakibatkan peningkatan kebutuhan Energi Listrik yang dibutuhkan tiap bulannya semakin bertambah. Serta Perlunya pengendali untuk urutan Kerja Pada 3 Pompa yang berguna untuk Mengimbangi jam Kerja yang berguna Untuk Menambah Umur Pemakaian Pompa. Berdasarkan permasalahan di atas penulis membuat inovasi yaitu “Sistem Kendali Tekanan Pada Pompa Air Sentrifugal Cooling Tower Menggunakan Metode PID Kontroler” Dimana pada sistem ini, diupayakan adanya pengurangan kebutuhan Energi Listrik yang dibutuhkan pada Sistem Keseluruhan mesin Cooling Tower, PID Kontroler digunakan untuk Membuat Pompa dapat berkerja Paralel danAlternate yang dapat mempercepat terpenuhinya Kebutuhan Air, Ketika adanya Pemakaian Air yang Cukup Besar maka Pompa akan berkerja secara Paralel atau 2 Pompa dan Ketika adanya Pemakaian Air yang lebih besar lagi maka adanya Alternate yang mengaktifkan 3 Pompa yang digunakan sebagai backup, dan Kecepatan dari Motor pada tiap Pompa akan Menyesuaikan dari Kondisi Tekanan Air di Pipa Discharge Pump. Serta Perlu adanya yang dapat mengimbangi Jam xvi Kerja Pada tiap Pompa yang berguna membuat motor berjangka panjang dalam penggunaannya. Setelah Melakukan pengujian didapatkan hasil nilai Parameter Kp = 0,29 , Ki = 0,016 dan Kd = 0,66. Untuk Pompa Air Sentrifugal tersebut. sedangkanIOT sebagai Monitoring keadaan Pompa dan Pengoperasiannya. Dalam Pengujian Energi ini Peneliti dengan Melakukan Pengambilan Data Konsumsi Energi Pada Pompa Air Sentrifugal Cooling Tower ini Melalui Power Meter, dimana data dibandingkan Energi Sebelum adanya Kontroler didapatkan rata-rata 1 hari pengunaan Sekitar 145,971 KWh , Sedangkan setelah diterapkan adanya Kontroler bisa mengalami Penurunan Sebesar 141,3 KWh , dimana bisa mengurangi Sekitar 2,8 % Penggunaan Konsumsi Energi yang ada.
==============================================================================================================================
PT. INDOLAKTO - Pandaan is one of the industries engaged in milk processing (dairy manufacturing). Products produced by PT. Indolakto FactoryPandaan is Indomilk Liquid Milk (SCI). PT. INDOLAKTO has a fairly large electrical energy requirement for each machine at the time of production. One of them is the Cooling Tower engine system where there are 3 Cooling Tower Machines and 3 Centrifugal Water Pumps as well as the Ground Tank/Pond containing the Air Cooling Tower. Where the Cooling Tower engine system is included in the ranking of the 3rd largest energy requirements of other machines at PT. INDOLAKTO. In the Cooling Tower Machine, there are 3 Centrifugal Water Pumps which are useful for distributing/supplying water from the Cooling Tower Water Pool to Production Machinery such as; Pasteurization Machines, Chiller Machines, Auto Clave Machines, etc. which are useful for Cooling Systems. The large energy requirement is caused by 3 Centrifugal Water Pumps, this Centrifugal Water Pump works manually which continuously every time at high speed (2100rpm) on 3 Centrifugal Water Pumps with pressure conditions of 2.8 Bar – 3 Bar on Pressure Gauge. Where when the production machine does not require a large amount of water in the cooling tower for the cooling system, but the water pump has been working manually and continuously which is considered less efficient which can increase the consumption of electrical energy, so that it can result in an increase in the need for electrical energy needed every month increasing. As well as the need for a controller for the sequence of work on 3 pumpswhich is useful for balancing working hours which is useful for increasing the service life of the pump. Based on the problems above, the author makes an innovation, namely "The Pressure Control System in the Cooling Tower Centrifugal Water Pump Using PID Controller Method" Where in this system, efforts are made to reduce the need for Electrical Energy needed in the Overall System of the Cooling Tower machine. , thePID Controller is used to make the pump work in parallel and alternate which can speed up the fulfillment of water needs, when there is a large enough water usage, the pump will work in parallel or 2 pumps and when there is a larger water usage, there is an alternative that activates 3 Pumps, and the Speed of the Motor on each Pump will Adjust from the Conditions of Water Pressure in the Discharge Pump Pipe. And can balance the working hours on each pump which is useful for making the motor long- term in use. After doing the test, the parameter values obtained are xviii Kp = 0,29 , Ki = 0,016 dan Kd = 0,66. For Centrifugal Water Pump. while IOT is usedto monitor the condition of the pump and its operation. In this energy test, the researcher collects energy consumption data on this cooling tower centrifugal water pump through a power meter, where the data is compared to energy before the controller is obtained, an average of 1 day of usage is around 145,971 KWh, while after the controller is implemented, it can experience a decrease of 141 ,3 KWh, which can reduce about 2.8% of the existing energy consumption.

Item Type: Thesis (Diploma)
Additional Information: RSEO 621.67 Nap s-1 2022
Uncontrolled Keywords: (Cooling Tower, Pompa Air Sentrifugal, PID Kontroler, HMI). (Cooling Tower, Centrifugal Water Pump, PID Controller, HMI).
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3070 Automatic control
Divisions: Faculty of Vocational > 36304-Automation Electronic Engineering
Depositing User: Mr. Marsudiyana -
Date Deposited: 16 Jul 2026 02:29
Last Modified: 16 Jul 2026 02:29
URI: http://repository.its.ac.id/id/eprint/135165