Pradipta, Rafli Izha (2026) Evaluasi Koordinasi Proteksi Akibat Integrasi PLN Dengan Mempertimbangkan Arc Flash Menggunakan Kurva Batas Energi Pada PT Pupuk Sriwidjaja Palembang Pabrik 2B. Other thesis, Institut Teknologi Sepuluh Nopember.
|
Text
5022221229-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only Download (9MB) | Request a copy |
Abstract
Keandalan dan keselamatan sistem tenaga listrik pada PT. Pupuk Sriwidjaja Palembang Pabrik 2B masih perlu dijaga seiring rencana integrasi pasokan dari PT. PLN yang bisa berpotensi mengubah tingkat arus hubung singkat dan kinerja pada koordinasi proteksi. Penelitian ini bertujuan untuk mengevaluasi pada koordinasi proteksi dan bahaya arc flash dengan menerapkan metode kurva batas energi pada sistem kelistrikan PT. Pupuk Sriwidjaja Palembang Pabrik 2B serta menyusun setelah proteksi yang selektif dan aman. Arc Flash dengan fenomena berbahaya yang dapat menghasilkan energi panas, ancaman keselamatan pekerja, luka bakar, kilatan cahaya dengan kerusakan mata. Maka dari semua analisa yang dilakukan akan mendapatkan koordinasi yang baik dan akan didapatkan nilai energi insiden dan arc flash boundary sesuai dengan standar IEEE 1584-2002. Dari beberapa perhitungan tersebut dapat ditentukan PPE sesuai dengan standar NFPA 70E 2018 yang sesuai dengan kategori level. Segala perhitungan dan simulasi pada tugas akhir ini akan menggunakan metode perhitungan sesuai dengan standar IEEE 1584-2002 dan dibuktikan melalui simulasi menggunakan software ETAP 21.0.1 sehingga dapat menentukan kategori level Personal Protective Equipment (PPE) yang sesuai.
=====================================================================================================================================
Reliability and safety of the electrical power system at PT. Pupuk Sriwidjaja Palembang Plant 2B must be maintained, especially given the planned integration of supply from PT. PLN which could potentially change short-circuit current levels and affect protection coordination performance. This study aims to evaluate protection coordination and arc flash hazards by applying the energy boundary curve method to the electrical system of PT. Pupuk Sriwidjaja Palembang Plant 2B and to develop selective and safe protective settings. Arc flash is a dangerous phenomenon that can produce thermal energy, threaten worker safety, cause burns, and emit intense light that can damage eyes. From the analyses performed, proper coordination will be achieved and incident energy values and arc flash boundaries will be obtained in accordance with IEEE 1584-2002. Based on those calculations it will be possible to determine PPE requirements according to NFPA 70E 2018 categories. All calculations and simulations in this thesis use the IEEE 1584-2002 calculation methods and are verified through simulations using ETAP 21.0.1 software, enabling determination of the appropriate Personal Protective Equipment (PPE) category levels.
| Item Type: | Thesis (Other) |
|---|---|
| Uncontrolled Keywords: | Arc Flash, PUSRI 2B, Koordinasi Proteksi, Integrasi PLN, Kurva Batas Energi, Personal Protective Equipment (PPE), Insiden Energi |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2861 Electric relays. Protective relays--Security measures. |
| Divisions: | Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis |
| Depositing User: | Rafli Izha Pradipta |
| Date Deposited: | 21 Jul 2026 05:02 |
| Last Modified: | 21 Jul 2026 05:02 |
| URI: | http://repository.its.ac.id/id/eprint/136056 |
Actions (login required)
![]() |
View Item |