Transformator daya merupakan peralatan yang penting dalam sistem tenaga listrik dan merupakan peralatan yang memerlukan pemantauan kondisi secara berkala untuk menjaga keandalan operasi dan juga mencegah terjadinya kegagalan. Penelitian yang dilakukan ini akan bertujuan untuk mengevaluasi kondisi kesehatan yang ada pada Main Transformer 1 (MT-1) dan Main Transformer 2 (MT-2) menggunakan metode Health Index yang berbasis parameter operasional dan pemeliharaan transformator. Parameter yang digunakan dalam penelitian ini meliputi parameter temperatur yang dianalisis berdasarkan Dissolved gas Analysis (DGA), inspeksi operasional temperatur minyak dan belitan, dan pembebanan, dan terdapat kandungan air. Setiap parameter yang digunakan akan dikonversi menjadi nilai indeks atau scoring index dan akan diberikan bobot yang dipengaruhi oleh tingkat pengaruhnya terhadap kondisi transformator, kemudian parameter tersebut akan dihitung menggunakan metode pembobotan untuk memperoleh hasil Health Index. Hasil penelitian yang dilakukan menunjukkan bahwa nilai Health Index pada MT-1 rentang 47,22 – 100% dan MT-2 rentang 31,88 – 100% adalah transformator yang mengalami proses penyusutan yang signifikan dari beberapa komponen hingga proses deteorisasi yang cukup serius dari beberapa komponen. Berdasarkan analisis yang digunakan keakuratan data juga dapat dipengaruhi oleh keterbatasan data yang digunakan untuk menghitung Health Index dalam satu periode. Penelitian ini menunjukkan bahwa metode Health Index mampu untuk mengintegrasikan berbagai parameter kondisi yang dilakukan pada transformator dan mendukung pemeliharaan bersifat preventif.
================================================================================================================================
Power transformers are critical equipment in power systems and require periodic condition monitoring to maintain operational reliability and prevent unexpected failures. This study aims to evaluate the health condition of Main Transformer 1 (MT-1) and Main Transformer 2 (MT-2) using the Health Index method based on transformer operational and maintenance parameters. The parameters used in this study include Disoolved Gas Analysis (DGA), operating temperature inspections of the transformer oil and windings, loading conditions, and water content. Each parameter was converted into an index value or Scoring Index and assigned a weighting factor according to its contribution fault on transformer condition. After that, these parameters were calculated using a weighting method to obtain the Health Index value. The results indicate that the Health Index values of Main Transformer 1 (MT-1) ranged from 47,22 – 100%, while those of Main Transformer 2 (MT-2) ranged from 31,88 – 100%. These results indicate that both transformers are undergoing significant degradation in several components, with some components eshibiting a serious level of deterioration. Based on the analysis, the accuracy of the Health Index assessment may also be influenced by the limitations of the data available for the calculating the Health Index during a specific assessment period. This study demonstrates that the Health Index method is capable of integrating various transformer condition parameters into a representative indicator for transformer health assessment and supports preventive and condition-based maintenance strategies.

Item Type: Thesis (Other)
Uncontrolled Keywords: Transformator Daya, Indeks Kesehatan, Parameter Pengoperasian, Parameter Pemeliharaan, Pembobotan Rata - Rata Power Transformer, Health Index, Operational Parameters, Maintenance Parameters, Weighted Average
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK6565.T7 Transformers
Divisions: Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Adi Rafly Dasahruddyn
Date Deposited: 24 Jul 2026 03:45
Last Modified: 24 Jul 2026 03:45
URI: http://repository.its.ac.id/id/eprint/137022

Actions (login required)

View Item View Item