Anandhita, Firda (2026) Perancangan Scada Pada Proses Flash Mixer Hingga Clearator Ipam Karang Pilang 3 Perumda Air Minum Surya Sembada Kota Surabaya. Project Report. [s.n.]. (Unpublished)
|
Text
2042221108-Project_Report.pdf - Accepted Version Restricted to Repository staff only Download (14MB) | Request a copy |
Abstract
SCADA berperan penting dalam mendukung monitoring dan kontrol proses IPAM secara real-time. Pada IPAM KP 3 PDAM Surya Sembada Kota Surabaya, sistem SCADA eksisting menggunakan perangkat lunak WebAccess/SCADA yang menerapkan lisensi berbasis jumlah tag. Oleh karena itu, pada kegiatan magang ini dilakukan perancangan sistem SCADA alternatif menggunakan LabVIEW untuk monitoring dan kontrol proses pengolahan air pada unit flash mixer hingga clearator. Perancangan sistem meliputi penyusunan P&ID, pengembangan HMI, implementasi logika akuisisi data, kontrol, dan alarm, serta pengujian komunikasi Modbus TCP/IP. Akuisisi data aktual dilakukan menggunakan satu unit power meter, sedangkan parameter kualitas air dan operasional pompa direpresentasikan menggunakan data simulasi. Sistem yang dikembangkan mampu menampilkan parameter tegangan, arus, daya, PF, pH, turbidity, dan level, serta menyediakan fungsi kontrol dan alarm pada HMI. Hasil pengujian menunjukkan bahwa komunikasi Modbus TCP/IP berhasil diimplementasikan dan seluruh fungsi monitoring, kontrol, serta alarm dapat berjalan sesuai perancangan. Selain itu, diusulkan penempatan instrumen pH, turbidity, dan level pada P&ID sebagai pengembangan monitoring kualitas air secara real-time.
=================================================================================================================================
SCADA plays a crucial role in supporting real-time monitoring and control of IPAM processes. At the IPAM KP 3 facility of PDAM Surya Sembada in Surabaya, the existing SCADA system uses WebAccess/SCADA software that employs a tag-count-based licensing model. Therefore, as part of this internship, an alternative SCADA system was designed using LabVIEW to monitor and control the water treatment process from the flash mixer to the clarifier. The system design included the preparation of P&IDs, HMI development, implementation of data acquisition, control, and alarm logic, as well as testing of Modbus TCP/IP communication. Actual data acquisition was performed using a single power meter, while water quality parameters and pump operational parameters were represented using simulated data. The developed system is capable of displaying voltage, current, power, PF, pH, turbidity, and level parameters, as well as providing control and alarm functions on the HMI. Test results show that Modbus TCP/IP communication was successfully implemented and that all monitoring, control, and alarm functions operate as designed. In addition, the placement of pH, turbidity, and level instruments on the P&ID is proposed as a means of enhancing real-time water quality monitoring.
| Item Type: | Monograph (Project Report) |
|---|---|
| Uncontrolled Keywords: | flash mixer–clearator, LabVIEW, SCADA, flash mixer–clearator, LabVIEW, SCADA |
| Subjects: | T Technology > T Technology (General) T Technology > TD Environmental technology. Sanitary engineering > TD455 Chemical precipitation. Coagulation. Flocculation. Water--Purification--Flocculation. T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK5105.585 TCP/IP (Computer network protocol) |
| Divisions: | Faculty of Vocational > Instrumentation Engineering |
| Depositing User: | FIRDA ANANDHITA |
| Date Deposited: | 30 Jul 2026 04:06 |
| Last Modified: | 30 Jul 2026 04:06 |
| URI: | http://repository.its.ac.id/id/eprint/140703 |