Aditya, Faisal Febri Pratama (2026) Analisis Gangguan Harmonisa Pada Rancangan Sistem Pembangkit Energi Surya On-grid Dermaga Dwimatama Pelabuhan Tanjung Emas Dengan Metode Simulasi. Other thesis, Institut Teknologi Sepuluh Nopember.
|
Text
5019201015-Undergraduate_Thesis.pdf Restricted to Repository staff only Download (46MB) | Request a copy |
Abstract
Sistem pembangkit listrik On-Grid, yang merupakan sistem kelistrikan penggabungan antara listrik konvensional dari PLN dengan listrik yang berasal dari energi terbarukan. Pembangkit listrik On-Grid menimbulkan adanya gangguan nilai dari harmonisa atau gangguan distorsi gelombang sinusoidal yang diakibatkan oleh gelombang lain diluar dari gelombang aslinya yang berasal dari beban non-linear, contohnya inverter, transformator, dan rectifier. Sistem kelistrikan Dermaga Dwimatama Pelabuhan Tanjung Emas menggunakan pembangkit listrik On-Grid yang menyebabkan nilai harmonisa melebihi nilai standar IEEE 519-2014 yaitu VIHD <5% pada tegangan <1kV dan <3% pada tegangan 1kV<69kV, serta VTHD <8% pada tegangan <1kV dan <5% pada tegangan 1kV<69kV. Perolehan nilai VTHD yang melebihi standar denga rata-rata nilai sebesar 22.47% pada tegangan 0.4 kV dan rata-rata nilai sebesar 24.78% pada tegangan 20 kV. Oleh karena itu, perlu dilakukan penekanan nilai harmonisa hingga memenuhi standar. Pemasangan dengan total tiga buah filter pasif single tuned pada BUS 1 PLN, BUS 1 AC PV, dan BUS to Load dengan nilai kapasitor dan induktor berturut-turut adalah 7.954µF dan 742.4 ohm, 5.908µF dan 00 ohm, serta 19304µF dan 0.007 ohm, mampu membuat nilai harmonisa yang semula melebihi standar hingga sesuai dengan standar dengan rata-rata nilai pada seluruh kondisi adalah 3.88% VTHD pada 0.4kV, dan 4.17% VTHD pada 20kV.
===============================================================================================================================
On-Grid electricity generation system, which is an electricity system that combines conventional electricity from PLN with electricity originating from renewable energy. On-Grid power plants cause disturbances in the value of harmonics or sinusoidal wave distortion caused by waves other than the original wave originating from non-linear loads, for example inverters, transformers and rectifiers. The Dwimatama Pier electrical system at Tanjung Emas Port uses an On-Grid power plant which causes harmonic values to exceed the IEEE 519-2014 standard value, namely VIHD <5% at voltage <1kV and <3% at 1kV voltage <69kV, and VTHD <8% at voltage <1kV and <5% at 1kV<69kV. Obtained VTHD values that exceed the standard with an average value of 22.47% at a voltage of 0.4 kV and an average value of 24.78% at a voltage of 20 kV. Therefore, it is necessary to emphasize the harmonic values until they meet the standards. Installation with a total of three single tuned passive filters on BUS 1 PLN, BUS 1 AC PV, and BUS to Load with capacitor and inductor values respectively 7.954µF and 742.4 ohm, 5.908µF and 00 ohm, and 19304µF and 0.007 ohm , able to make harmonic values that previously exceeded the standard until they are in accordance with the standard with the average value at all conditions are 3.88% VTHD at 0.4kV, and 4.17% VTHD at 20kV.
| Item Type: | Thesis (Other) |
|---|---|
| Uncontrolled Keywords: | Beban Non-Linear, Harmonisa, Pembangkit Listrik ¬On-Grid, VIHD and VTHD, Non-Linear Loads, On-Grid Power Plants, VIHD and VTHD |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1056 Solar power plants. Ocean thermal power plants T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK7872.F5 Filters (Electric) |
| Divisions: | 61101-Magister Management Technology |
| Depositing User: | Faisal Febri Pratama Aditya |
| Date Deposited: | 05 Aug 2026 01:03 |
| Last Modified: | 05 Aug 2026 01:03 |
| URI: | http://repository.its.ac.id/id/eprint/143083 |