Juningtijastuti, Juningtijastuti (2010) Optimisasi Parameter Dan Lokasi UPFC Untuk Mereduksi Rugi Daya Pada Jaring Transmisi Menggunakan Bacteri Foraging Algorithm. Masters thesis, Institut Teknologi Sepuluh Nopember.
|
Text
2208201008-Master_Thesis.pdf Restricted to Repository staff only Download (11MB) | Request a copy |
Abstract
Bacteria Foraging Algorithm Optimization (BFA) merupakan salah satu metode untuk menyelesaikan permasalahan yang berkaitan dengan optimisasi. Dengan menentukan parameter dan lokasi Unified Power Flow Controller (UPFC) yang tepat pada jaring transmisi, dapat menurunkan rugi daya jaring transmisi.. BFA melalui bakteri E-Coli, memiliki empat strategi yang diperlukan untuk menentukan lifetime, peningkatan produksi dan evaluasi bakteri. BFA beroperasi pada suatu populasi bakteria yang bekerja secara serempak, sehingga berbagai kemungkinan terjadi kesalahan dalam proses komputasi dapat dikurangi. Melalui evolusi nutrisi, bakteri yang mendapatkan nutrisi paling sedikit merupakan solusi yang lebih baik untuk semua permasalahan optimisasi. Untuk itu, dalam penelitian ini BFA akan diaplikasikan pada sistem jaring transmisi 500 kV Jamali dan sistem 26 bus IEEE. Hasil simulasi BFA menunjukkan bahwa parameter dan lokasi UPFC yang optimal, akibatnya sistem tegangan rata-rata memenuhi rentang tegangan yang diijinkan dan minimais rugi daya pada jaring transmisi terpenuhi.
=======================================================================================================================================
Bacteria Foraging Algorithm Optimization (BFA) is one of the method to solve the optimization problems related. The parameters and location of Unified Power Flow Controller (UPFC) is determined to reduce the transmission losses power. BFA by E-Col bacteria, have four strategies needed to determine the lifetime, increasing the production and evaluation of bacteria. BFA operates on population of bacteria that work in uniform, so the possibility of errors in the process can be reduced. BFA is applied in 500 kV Jamali systems and 26 bus IEEE systems. The simulation the resulted using BFA method so the optimal parameters and location of UPFC. The average of voltage profile are still in the allowed voltage range and the minimization of power losses for transmission are achieved.
| Item Type: | Thesis (Masters) |
|---|---|
| Additional Information: | RTE 621.319 Jun o 2010 3100010039676 WEEDING |
| Uncontrolled Keywords: | UPFC, Bacteria Foraging Algorithm (BFA), Rugi Daya, Power loss |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK201 Electric Power Transmission Q Science > QA Mathematics > QA9.58 Algorithms T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK5105.546 Computer algorithms |
| Divisions: | Faculty of Electrical Technology > Electrical Engineering > 20101-(S2) Master Thesis |
| Depositing User: | Anis Wulandari |
| Date Deposited: | 19 Aug 2026 05:03 |
| Last Modified: | 19 Aug 2026 05:03 |
| URI: | http://repository.its.ac.id/id/eprint/144364 |
Actions (login required)
![]() |
View Item |