Identifikasi Kebocoran Air Pada Sistem Perpipaan Di PDAM Surabaya Dengan Menggunakan Parameter Laju Penurunan Chlorine Dan Laju Pertumbuhan Bakteri Coli

Finansyah, Rudhy Wahyu (2003) Identifikasi Kebocoran Air Pada Sistem Perpipaan Di PDAM Surabaya Dengan Menggunakan Parameter Laju Penurunan Chlorine Dan Laju Pertumbuhan Bakteri Coli. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 3301201001-Master_Thesis.pdf] Text
3301201001-Master_Thesis.pdf
Restricted to Repository staff only

Download (8MB)

Abstract

Dalam upaya mengontrol kualitas pelayanan, PDAM Surabaya melakukan pemantauan kadar sisa chlorine dan kadar coli secara rutin di sistem distribusi. Berdasar berbagai teori yang ada, laju penurunan kadar chlorine dan laju pertumbuhan atau pertumbuhan kembali bakteri coli dipengaruhi oleh transfer massa pada dinding elemen pipa dan elemen kimiawi yang terkandung dalam air yang ada dalam pipa. Bila pipa bocor, maka sangat dimungkinkan terjadinya kontaminasi air dalam pipa dengan lingkungan di luar pipa yang akan mengakibatkan laju penurunan kadar chlorine berlangsung lebih cepat dan laju pertumbuhan bakteri coli lebih banyak dibanding kondisi pipa tidak bocor.Hasil penelitian menunjukkan bahwa identifikasi kebocoran air di sistem perpipaan air minum dapat diprediksikan bilamana nilai laju penurunan kadar chlorine dan laju pertumbuhan bakteri coli diketahui, dengan memanfaatkan fungsi matematis sebagai berikut:

\(f = -1,144 + 0,652\ k\text{ chlor} + 0,58\ k\text{ coli}\)

Pipa diprediksikan tidak bocor bila nilai $f$ berada di sekitar -0,910, sedang bila nilai $f$ berada di sekitar 0,910, maka pipa diprediksikan bocor. Laju penurunan kadar chlorine dan laju pertumbuhan bakteri coli semakin besar pada pipa yang bocor, dibanding pipa yang tidak bocor.
Hasil penelitian ini juga menunjukkan bahwa variabel diameter dan tekanan secara signifikan mempengaruhi laju penurunan kadar chlorine, sedang umur pipa tidak berpengaruh, sedang pada laju pertumbuhan bakteri coli variabel diameter, tekanan dan usia pipa tidak berpengaruh secara signifikan (pada signifikansi $95%$).
Penelitian ini menyimpulkan bahwa parameter laju penurunan kadar chlorine dan laju pertumbuhan bakteri coli dapat digunakan untuk identifikasi kebocoran pipa di samping untuk memantau kualitas air di sistem distribusi.
==================================================================================================================================
In an effort to control the service quality, PDAM Surabaya monitors the water quality by chlorine residual and coli bacteria concentration routinely. From several references, rate of chlorine concentration decrease and rate of coli bacteria growth or regrowth in the pipelines are influenced by mass transfer from the pipe wall element and water chemicals element in the pipeline. Rate of chlorine concentration decrease and coli bacteria growth are faster in the pipeline with leakage, caused of contamination, than in the pipeline without leakage.The result of this research shows that leakage identification in distribution system can be predicted from the rate of chlorine concentration decrease and rate of coli bacteria growth, following the mathematical function below:

\(f = -1,144 + 0,652\ k\text{ chlor} + 0,58\ k\text{ coli}\)

The pipeline was not leaks if $f$ value is around $-0,910$ and pipelines was leaks if $f$ value is around $+0,910$. Rate of chlorine concentration decrease and rate of coli bacteria growth is higher in the leaked pipe than unleaked pipe in the pipelines.The result of the research also shows that the pipe pressure and pipe diameter variables influencing significantly the rate of chlorine concentration decrease but not for pipe age, otherwise the pipe pressure, pipe diameter and pipe age variables are not influencing significantly the rate of coli bacteria growth (on the $95%$ signification degree).This research concluded that rate of chlorine concentration decrease and coli bacteria growth in the pipeline could be used to identify the pipe leakage, besides by monitoring the water quality in the distribution system.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Laju penurunan kadar chlorine, Laju pertumbuhan bakteri coli, fungsi matematis. , Rate of chlorine concentration decrease, Rate of coli bacteria growth, the mathematical function
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA1637 Image processing--Digital techniques. Image analysis--Data processing.
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22101-(S2) Master Thesis
Depositing User: magang .
Date Deposited: 22 Sep 2026 07:06
Last Modified: 22 Sep 2026 07:08
URI: http://repository.its.ac.id/id/eprint/144789

Actions (login required)

View Item View Item