Penentuan Kadmium Menggunakan Elektroda Karbon Termodifikasi Polipirol/Asam Humat secara Voltametri Siklik

Oktarini, Rotua (2012) Penentuan Kadmium Menggunakan Elektroda Karbon Termodifikasi Polipirol/Asam Humat secara Voltametri Siklik. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 1408100043-Undergraduate_thesis.pdf] Text
1408100043-Undergraduate_thesis.pdf
Restricted to Repository staff only

Download (37MB)

Abstract

Pada penelitian ini dilakukan dengan elektroda karbon termodifikasi polipirol/asam humat yang digunakan untuk penentuan kadmium. Dengan adanya polipirol/asam humat dapat meningkatkan arus potensial oksidasi pada larutan kadmium sehingga didapat arus puncak voltamogram oksidasi yang semakin meningkat dengan bertambahnya konsentrasi larutan kadmium. Penelitian ini menggunakan teknik voltametri siklik dengan memberikan range potensial -1 sampai dengan +1 V, laju sapuan 100 mVs⁻¹. Arus puncak oksidasi pada elektroda polipirol dan polipirol/asam humat adalah sekitar -0.24 V. Dari persamaan kurva lineritas maka dapat dihitung limit deteksi dan sensitivitas kedua elektroda. Limit deteksi dan sensitivitas pada elektroda pirol yaitu 0.30 pM dan 0.0082 mA.pM⁻¹.mm⁻², Sedangkan limit deteksi dan sensitifitas elektroda polipirol/asam humat 0.15 pM dan 0.0030 mA.pM⁻¹.mm⁻².
===================================================================================================================================
In this research carbon modified polypyrrole/humic acid has been studied for the determination of cadmium. In the presence of polypyrrole/humic acid can increases oxidation peak current voltamogram cadmium solution with increasing concentration of cadmium. This study using cyclic voltamety technique with potential range -1 to +1 V, sweep rate 100 mVs⁻¹. Oxidation peak current polypyrolle/humic acid is about -0.24 V. From equation lineritas curve can be calculated detection limit and sensitivity of both electrodes. Detection limit and sensitivity of the pyrrole electrode is 0.30 pM and 0.0082 mA.pM⁻¹.mm⁻², while polypyrolle/humic acid electrode is 0.15 pM and 0.0030 mA.pM⁻¹.mm⁻².

Item Type: Thesis (Other)
Additional Information: RSKi 541.37 Okt p
Uncontrolled Keywords: Karbon, asam humat, polipirol, dan voltametri siklik, carbon, gold, polypyrrole, humic acid, cyclic voltammetry
Subjects: Q Science > QD Chemistry > QD481 Chemical structure.