Utomo, Dwi Yudi Prasetiyo (2011) Perancangan Modifikasi Struktur Apartemen dengan Metode SRPMM dan Flat Slab. Other thesis, Institut Teknologi Sepuluh Nopember.
|
Text
3106100107-Undergraduate_Thesis.pdf Restricted to Repository staff only Download (23MB) |
Abstract
Bahasa Indonesia: Bangunan yang dibangun menggunakan SRPM dengan balok interior di wilayah gempa menengah masih mempunyai kekurangan jika dibandingkan dengan SRPM tanpa balok interior, ditinjau dari segi ekonomi dan tinggi gedung. Dari segi ekonomi, diperlukan biaya untuk beton, besi dan bekisting untuk komponen balok. Dari segi tinggi gedung, SRPM dengan balok interior mempunyai tinggi lebih jika dibandingkan dengan SRPM tanpa balok interior. Flat slab/lantai cendawan adalah suatu sistem bangunan tanpa balok, namun balok-balok tepi pada tepi-tepi luar lantai boleh jadi ada atau tidak ada. Flat slab mempunyai kekuatan gaya geser cukup dengan adanya salah satu atau kedua hal berikut : (a) drop panel, pertambahan tebal pelat di dalam daerah kolom; atau (b) kepala kolom (column capital), pelebaran yang mengecil dari ujung kolom atas. Untuk menahan beban gempa di wilayah gempa 3, flat slab direncanakan sebagai struktur rangka pemikul momen menengah (SRPMM). Sistem struktur dalam menerima beban gempa berperilaku dengan mekanisme Ientur. Dari hasil analisa, drop panel mempunyai peranan penting dalam menahan momen tumpuan yang besar serta gaya geser pelat di sekitar kolom. Jumlah pondasi liang pancang yang dibutuhkan leo/om eksterior lebih banyak dibandingkan kolom interior.
=======================================================================================================================================
The building was built using interior beams in Moment Resisting Frame system with intermediate earthquake area still has shortcomings compared with the Moment Resisting Frame system without interior beams, in terms of economic and buildings height. In terms of economics, it costs for concrete, formwork and steel of beams. In terms of building height, Moment Resisting Frame with interior beams have more height better than without interior beams. Flate slab is a building system with no beams, but beams on the edge of the outer edges of the floor may be there or not. Flate slab has sufficient shear strength to the existence of one or both of the following: (a) the drop panel, the increase in thick plate in the column area; or (b) the head of the column (column capital), widening of the narrowing of the end of the column above. To resist earthquake loads in the quake region 3, a flate slab structure planned as a intermediate moment resisting frame system. System structure in the earthquake load acting with flexible mechanisms.
| Item Type: | Thesis (Other) |
|---|---|
| Additional Information: | 690.831 4 Uto p |
| Uncontrolled Keywords: | flat slab, SRPMM, jlate slab, Intermediate Moment Resisting Frame System |
| Subjects: | T Technology > TA Engineering (General). Civil engineering (General) > TA658 Structural design |
| Divisions: | Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis |