Studi Perilaku Elemen Struktur Kolom Berpenampang Baja dan Baja Berintikan Beton pada Bangunan Akibat Beban Gempa

Yudha, Andrey (2010) Studi Perilaku Elemen Struktur Kolom Berpenampang Baja dan Baja Berintikan Beton pada Bangunan Akibat Beban Gempa. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 3107100608-Undergraduate_Thesis.pdf] Text
3107100608-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (6MB)

Abstract

Salah satu jenis profil baja komposit yang banyak diterapkan adalah baja yang diisi oleh beton, atau yang dalam istilah teknis disebut concrete filled steel tube (CFT). Penggunaan sistem profil ini menawarkan berbagai keunggulan yang signifikan jika dibandingkan dengan profil baja konvensional maupun struktur beton bertulang biasa. Keunggulan utamanya terletak pada interaksi dinamis antara material baja dan beton inti, di mana elemen baja berfungsi untuk meredam risiko tekuk lokal, sementara beton inti mendapatkan peningkatan kekuatan akibat efek kekangan dari tabung baja di sekelilingnya.
Dalam penelitian Tugas Akhir ini, penulis melakukan perbandingan terhadap tiga model perancangan gedung yang berbeda. Gedung pertama dan kedua dirancang menggunakan model profil baja komposit berbentuk penampang tabung baja isi beton persegi (rectangular) serta lingkaran (circular), sedangkan gedung ketiga menggunakan profil baja tipe king cross (XH) khusus pada bagian elemen struktur kolomnya. Masing-masing dari gedung tersebut direncanakan memiliki ketinggian sepuluh tingkat dan diasumsikan berdiri pada wilayah dengan tingkat risiko gempa yang tinggi (zona gempa 6). Analisis dan perbandingan lebih lanjut difokuskan pada perilaku struktural gedung, yang mencakup parameter daktilitas, simpang struktur, serta karakteristik bentuk sambungan antar-kolom maupun antara kolom dengan balok.
Berdasarkan serangkaian analisis yang telah dilakukan, diperoleh beberapa kesimpulan utama sebagai berikut: pertama, kolom dengan profil XH menunjukkan perilaku struktur yang kurang daktail apabila disandingkan dengan kolom jenis CFT; kedua, kapasitas daya dukung terhadap beban aksial serta momen lentur pada kolom CFT jauh lebih unggul dibandingkan dengan kolom XH; dan ketiga, simpang atau drift yang terjadi pada kolom XH tercatat lebih kecil daripada kolom CFT.
======================================================================================================================================
One of the structural applications of composite steel involves the use of concrete filled steel tube (CFT) systems. This specific column system provides numerous advantages over conventional steel profiles or standard reinforced concrete structures. A primary benefit stems from the collaborative interaction between the enclosing steel tube and the inner concrete core, where local buckling of the steel is effectively delayed through the structural restraint provided by the concrete, while the overall compressive strength of the concrete is enhanced due to the confinement effect exerted by the steel tube.
Within the scope of this Final Project, the author evaluates and compares three distinct building models. The first and second structures utilize composite steel profiles consisting of rectangular and circular concrete filled steel tubes (CFT), whereas the third structure incorporates a king cross steel profile (XH) for its column structural elements. Each building is designed with a height of ten stories and is assumed to be situated within a high-risk seismic region (Seismic Zone 6). Consequently, the study focuses on evaluating structural performance indicators, including element behavior, story drift, and the mechanical response of column-to-column and column-to-beam connections.
The findings derived from this research can be summarized into three main points: first, the XH profile exhibits lower ductility performance relative to the CFT columns; second, the axial load capacity and bending moment resistance of the CFT profiles significantly surpass those of the XH columns; and third, the story drift characteristics observed in the XH profiles are lower than those recorded for the CFT systems.

Item Type: Thesis (Other)
Additional Information: RSS 624.177 25 Yud s
Uncontrolled Keywords: kolom komposit; tekuk lokal; CFT; XH; daktilitas; diagram momen-kurvatur; wilayah gempa tinggi, column composite; local buckling; ductility; Moment-curvature diagram; high seismic zone.
Subjects: H Social Sciences > HG Finance > HG4028.V3 Valuation. Economic value
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: magang .
Date Deposited: 29 Oct 2026 03:09
Last Modified: 29 Oct 2026 03:09
URI: http://repository.its.ac.id/id/eprint/145992