Studi Eksperimental Pengaruh Variasi Ketinggian Floating Photovoltaic Module Dan Tilt Angle Terhadap Thermal Behaviour Dan Relative Humidity Pada Panel Surya

Fathoni, Muhammad Reza (2026) Studi Eksperimental Pengaruh Variasi Ketinggian Floating Photovoltaic Module Dan Tilt Angle Terhadap Thermal Behaviour Dan Relative Humidity Pada Panel Surya. Masters thesis, Institut Teknogi Sepuluh Nopember.

[thumbnail of 6007241001-Master_Thesis.pdf] Text
6007241001-Master_Thesis.pdf - Accepted Version
Restricted to Repository staff only

Download (3MB) | Request a copy

Abstract

Panel surya terapung (Floating Photovoltaic/FPV) merupakan teknologi inovatif yang memanfaatkan permukaan air untuk menghasilkan energi terbarukan, menawarkan efisiensi lebih tinggi dibandingkan panel surya darat karena efek pendinginan alami. Namun, dalam kondisi iklim tropis Indonesia, pengaruh termal lingkungan dan kelembaban relatif terhadap kinerja FPV masih belum banyak diteliti secara komprehensif. Penelitian ini bertujuan untuk menganalisis pengaruh temperatur ambien, temperatur air, dan kelembaban relatif terhadap performa panel surya terapung 160 Wp dengan variasi ketinggian modul (250–750 mm) dan sudut kemiringan (5°, 15°, dan 25°) dalam kondisi iklim tropis. Penelitian dilakukan secara eksperimental di kolam Graha Institut Teknologi Sepuluh Nopember (ITS) Surabaya selama satu bulan, dengan pengambilan data pada pukul 09:00–15:00 setiap hari. Data primer dikumpulkan menggunakan sensor DHT22 untuk temperatur dan kelembaban, dan solar power meter untuk pengukuran output daya panel. Parameter yang diukur meliputi temperatur modul PV (bagian depan dan belakang), arus, tegangan, daya output, temperatur air, temperatur lingkungan, kelembaban relatif, dan intensitas radiasi matahari. Analisis data dilakukan untuk menentukan Performance Ratio (PR), efisiensi modul, Fill Factor (FF), dan Ideality Factor (IF) pada setiap variasi ketinggian dan sudut kemiringan. Hasil penelitian menunjukkan bahwa ketinggian pemasangan modul yang lebih tinggi dari permukaan air (500 dan 750 mm) memberikan performa termal dan elektrik yang lebih baik dibanding ketinggian terendah (250 mm), dengan kombinasi ketinggian 500–750 mm dan sudut 25° menunjukkan performa paling menguntungkan di antara sembilan konfigurasi yang diuji.
==============================================================================================================================================
Floating Photovoltaic (FPV) panels are innovative technologies that utilize water surfaces to generate renewable energy, offering higher efficiency compared to land-based solar panels due to natural cooling effects. However, in tropical Indonesian climate conditions, the influence of ambient thermal conditions and relative humidity on FPV performance remains insufficiently studied. This research aims to analyze the effects of ambient temperature, water temperature, and relative humidity on the performance of a 160 Wp floating solar panel with variations in module height (250–750 mm) and tilt angle (5°, 15°, and 25°) under tropical climate conditions. The study was conducted experimentally at the Graha reservoir of the Institute of Technology Sepuluh Nopember (ITS) Surabaya over one month, with data collection performed from 09:00 to 15:00 daily. Primary data were collected using DHT22 sensors for temperature and humidity, anemometers for wind speed, and solar power meters for measuring panel power output. Parameters measured include PV module temperature (front and back), current, voltage, power output, water temperature, ambient temperature, relative humidity, and solar radiation intensity. Data analysis was performed to determine Performance Ratio (PR), module efficiency, Fill Factor (FF), and Ideality Factor (IF) for each variation of height and tilt angle. A mathematical model was developed to predict the relationship between thermal parameters, relative humidity, and FPV system performance. Results show that higher module height above the water surface (500 and 750 mm) provides better thermal and electrical performance compared to the lowest height (250 mm), with the combination of 500–750 mm height and 25° tilt angle showing the most favorable performance among the nine tested configurations.

Item Type: Thesis (Masters)
Uncontrolled Keywords: panel surya terapung (FPV), temperatur termal, kelembaban relatif, ketinggian modul, sudut kemiringan, performance ratio, iklim tropis, floating photovoltaic (FPV), thermal temperature, relative humidity, module height, tilt angle, performance ratio, tropical climate.
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ808 Renewable energy sources. Energy harvesting.
T Technology > TJ Mechanical engineering and machinery > TJ810.5 Solar energy
Divisions: Faculty of Industrial Technology and Systems Engineering (INDSYS) > Mechanical Engineering > 21101-(S2) Master Thesis
Depositing User: Muhammad Reza Fathoni
Date Deposited: 18 Nov 2026 08:04
Last Modified: 18 Nov 2026 08:04
URI: http://repository.its.ac.id/id/eprint/146066

Actions (login required)

View Item View Item