SIMULASI CYCLE-TEMPO PENGARUH ALIRAN MASSA EKSTRAKSI UAP UNTUK HIGH PRESSURE FEEDWATER HEATER TERHADAP PERFORMA PLTU 200 MW PT. PJB GRESIK

BRAMANTYA, ARI TRI (2016) SIMULASI CYCLE-TEMPO PENGARUH ALIRAN MASSA EKSTRAKSI UAP UNTUK HIGH PRESSURE FEEDWATER HEATER TERHADAP PERFORMA PLTU 200 MW PT. PJB GRESIK. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2108100027-Undergraduate_thesis.pdf]
Preview
Text
2108100027-Undergraduate_thesis.pdf - Published Version

Download (1MB) | Preview

Abstract

Salah satu jenis pembangkit listrik yang banyak di
gunakan adalah pembangkit listrik tenaga uap (PLTU) yang
bekerja berdasarkan siklus Rankine. Salah satu cara
meningkatkan efisiensi dari sebuah PLTU adalah dengan
menambahkan feedwater heater (FWH) ke dalam sistem, yang
bermaksud meningkatkan temperatur air yang akan diuapkan di
dalam boiler. Energi yang digunakan FWH berasal dari ekstraksi
turbin uap, dengan jumlah aliran massa dan tekanan tertentu.
Proses ektraksi yang kurang tepat dapat mengakibatkan efisiensi
turbin menurun dan dapat mengakibatkan efisiensi pembangkit
menurun. Studi lebih lanjut diperlukan untuk mengetahui
proporsi yang tepat pada ekstraksi turbin uap.
Penelitian mengenai pengaruh aliran massa ekstraksi
turbin uap ini dilakukan dengan analisis termodinamika. Analisis
termodinamika dapat dilakukan dengan bantuan software Cycle -
Tempo. Pemodelan dilakukan mulai dari kondisi eksisting
pembangkit dan variasi yang dilakukan dengan presentase aliran
massa antara HPH 1 : HPH 2 sebesar (6% : 10%) hingga (10% :
6% ) dengan kondisi eksisting (8% : 8%) dan presentase aliran
massa antara HPH 3 : Deaerator sebesar (2% : 6%) hingga ( 6%
: 2% ) dengan kondisi eksisting HPH 3 : Deaerator ( 4% : 4% ).
Pengurangan presentase aliran massa ekstraksi uap pada
high pressure turbin dapat meningkatkan daya pembangkit
namun dapat membuat efisiensi pembangkit turun karena heat
rate meningkat begitu pula sebaliknya. Pengurangan presentase
aliran massa ekstraksi uap pada intermediate pressure turbin
dapat menurunkan daya dan dapat membuat efisiensi pembangkit
turun karena heat rate yang bertambah besar dan begitu pula
sebaliknya. Dari variasi yang dilakukan diambil variasi yang
terbaik adalah variasi presentase aliran massa uap HPH 1 : HPH
2 sebesar (7% : 9%) dan pada HPH 3 : Deaerator sebesar (5% :
3%) yang menghasilkan daya sebesar 201.057 MW dan efisiensi
43.513%

========================================================================

One type of power plant that is widely used is the steam
power plant which works based on Rankine cycle . One way to
improve the efficiency of a steam power plant is by adding a
feedwater heater ( FWH ) into the system , which use to increase
the temperature of the water to be evaporated in the boiler . FWH
used the energy derived from the extraction of steam turbines,
with exact mass flow and pressure. Lack of proper extraction
process can decreased turbine efficiency and may result in
decreased plant efficiency . Further studies are needed to
determine the exact proportion to the extraction from steam
turbine.
Research on the influence of the mass flow extraction
from steam turbine can be done by using thermodynamics
analysis . Thermodynamic analysis can be done with the help of
Cycle – Tempo software . Modelling of steam power plant carried
out from the existing condition of steam power plant. Variation
made with a percentage of the mass flow between HPH 1 : HPH 2
of (6 % : 10 %) to (10 % : 6 %) with the existing condition ( 8 % :
8 % ) and the percentage of mass flow between HPH 3 :
Deaerator from (2 % : 6 %) to (6 % : 2 %) with the existing
condition between HPH 3 : Deaerator (4 % : 4 %).
Decreasing the mass flow percentage at high pressure
turbine extraction can improve the power output from the turbine
but can decrease power plant efficiency because power plant heat
rate increases and vice versa . Decreasing the mass flow
percentage in the intermediate pressure turbine can reduce power
output from the turbine and can make power plant efficiency
decreasing because of power plant heat rate increases and vice
versa. Best variations performed drawn is the variation
percentage of the mass flow of steam HPH 1 : HPH 2 of ( 7 % : 9
% ) and the HPH 3 : Deaerator for ( 5 % : 3 % ) that produce
power equal to 201.057 MW and efficiency of 43.513 %

Item Type: Thesis (Undergraduate)
Additional Information: RSM 621.312 132 Bra s
Uncontrolled Keywords: Aliran Massa Ekstraksi Turbin Uap, Performa Pembangkit, Software Cycle - Tempo
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ164 Power plants--Design and construction
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21201-(S1) Undergraduate Thesis
Depositing User: Anis Wulandari
Date Deposited: 13 Jan 2017 08:52
Last Modified: 26 Dec 2018 06:52
URI: http://repository.its.ac.id/id/eprint/1565

Actions (login required)

View Item View Item