Agustinus, Dheisa Orizanto (2016) Simulasi Distribusi Kecepatan Aliran Uap Yang Melewati Turbin Ventilator Valve Menuju Kondensor Yang Mengenai Deflektor Dengan Penambahan Sheet Protection Berbentuk Setengah Lingkaran PLTU Tanjung Jati B Jepara. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
2109100104-Undergraduate_Theses.pdf - Published Version Download (3MB) | Preview |
Abstract
Kondensor merupakan alat penukar panas yang dapat digunakan untuk memanfaatkan atau mengambil panas dari suatu fluida untuk dipindahkan ke fluida lain. Jenis kondensor yang digunakan pada Pembangkit Listrik Tenaga Uap (PLTU) Tanjung Jati B adalah Twin Shell Single Pressure Surface Condenser. Kondensor merupakan salah satu komponen penting dalam siklus Rankine, apabila kondensor tidak berfungsi maka suatu pembangkit listrik tidak dapat beroperasi.
Penelitian dilakukan dengan menganalisis distribusi kecepatan dan temperature uap dari turbin ventilator valve menuju kondensor setelah melalui steam deflector dengan dan tanpa adanya baffle, geometri baffle dan ketinggian baffle. Fluida kerja yang digunakan berupa uap air dengan kecepatan 1374.25 m/s yang dimodelkan sebagai fluida yang mengalir pada suatu pipa kemudian mengenai steam deflector sebelum memasuki kondensor. Studi numerik dilakukan secara 3 (tiga) dimensi dengan kondisi aliran steady, incompressible dan turbulen dengan prinsip Computational Fluid Dynamic (CFD) menggunakan perangkat lunak GAMBIT 2.4.6 untuk tahapan permbuatan domain dan disimulasikan dalam perangkat lunak FLUENT 6.3.26.
Dari hasil simulasi menggunakan FLUENT 6.3.26 bisa didapatkan karakteristik aliran berupa visualisasi aliran berupa kontur kecepatan, vector kecepatan dan distribusi kecepatan pada permukaan pipa condenser dengan variasi ketinggian sheet protection. Variasi pertama sheet protection terletak di y = -1 m, kedua y = -1.2 m dan yang ketiga y = -1.5 m. Setelah dilakukan simulasi didapatkan kecepatan yang paling tinggi pada permukaan pipa condenser berturut-turut 19 m/s, 17 m/s dan 16 m/s. Dengan kecepatan yang sudah didapat dari simulasi kemudian dilakukan analisis fatigue terhadap ketiga kondisi penelitian. Setelah dilakukan analisis fatigue dengan penambahan sheet protection pada condenser, tube condenser tidak mengalami kerusakan dikarenakan tegangan yang terjadi berada di bawah kurva fatigue limit.
==================================================================================================================
The condenser is a heat exchanger that can be used to take heat
from a fluid to be transferred to another fluid. Type of condenser
used in steam power plant (power plant) Tanjung Jati B is a Twin
Shell Single Pressure Surface Condenser. The condenser is one of
the important components in the Rankine cycle, if the condenser
does not work then a power plant can not operate.
The study was conducted by analyzing the distribution of the
velocity and temperature of the steam from turbine ventilator valve
to the condenser through steam deflector with and without the
protection sheet. The working fluid that is used in the form of water
vapor at a speed of 1374.25 m/s which is modeled as a fluid flowing
in a pipe then hit steam deflector before entering the condenser.
Numerical studies performed as 3 (three) dimensional study with a
steady flow conditions and turbulent with the principles of
Computational Fluid Dynamics (CFD), used GAMBIT 2.4.6
software to make modelling domain and simulated in FLUENT
6.3.26 software.
From the simulation results can be obtained using FLUENT 3.6.26
flow characteristics such as flow visualization in the form of
contour speed, velocity vector and velocity distribution on the pipe
surface condenser with a height variation of sheet protection. The
first variation of sheet protection is located at y = -1 m, the seconf
y = -1.2 m and the third y = -1.5 m. After the simulation, the highest
speed in the pipe surface condenser in a row 19 m / s, 17 m / s and
16 m / s. With the speed that has been obtained from the simulation
and then analyzed of fatigue against the three conditions of the
study. After the analysis of fatigue with the addition of sheet
protection on the condenser, condenser tube is not damaged due to
stress are at a level below the curve fatigue limit.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | condenser, steam deflector, sheet protection, Kondensor, Steam Deflector, sheet protection. |
Subjects: | T Technology > TJ Mechanical engineering and machinery T Technology > TJ Mechanical engineering and machinery > TJ164 Power plants--Design and construction |
Divisions: | Faculty of Industrial Technology > Mechanical Engineering |
Depositing User: | AGUSTINUS DHEISA ORIZANTO |
Date Deposited: | 09 Mar 2017 02:32 |
Last Modified: | 26 Dec 2018 03:43 |
URI: | http://repository.its.ac.id/id/eprint/1817 |
Actions (login required)
View Item |