ANALISA EKSITASI TRANSIEN PADA POROS LOW PRESSURE BOILER FEED PUMP PT.PJB UP GRESIK

ELDWIN, - (2017) ANALISA EKSITASI TRANSIEN PADA POROS LOW PRESSURE BOILER FEED PUMP PT.PJB UP GRESIK. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2713100077-undergraduate-theses.pdf]
Preview
Text
2713100077-undergraduate-theses.pdf - Published Version

Download (2MB) | Preview

Abstract

Dalam sistem Heat Recovery Steam Generator (HRSG) terdapat low pressure boiler feed pump yang merupakan bagian penting dalam menunjang proses yang berlangsung dalamnya. Pompa ini memiliki poros yang mana sering mengalami kegagalan yaitu sekitar 8-10 dalam setahun. Selama pengoperasiannya, poros menerima pembebanan yang dapat berlangsung secara dinamis yang timbul karena adanya pengaruh dari luar pompa tersebut seperti adanya perubahan tegangan listrik yang mengalir ke pompa, adanya pengaruh dari buka tutup katup air yang menuju pompa. Proses mencari tahu pengaruh dari pembebanan yang berubah-ubah (transien) dilakukan dengan menggunakan software Ansys. Percobaan ini menggunakan 3 ukuran pembebanan yaitu 17.233 N, 22.306 N, dan 28.025 N. Dari pembebanan tersebut diperoleh 20 nilai displacement untuk tiap pembebanannya. Disamping itu, diketahui batas pembebanan yang dapat diberikan pada pompa dan juga diketahui defleksi maksimum yang dapat terjadi pada pompa. Dari ketiga gaya tersebut diperoleh nilai displacement terbesar yaitu 2,9631 mm, 3,8354 mm dan 4,8186 mm. Defleksi yang terjadi masih masuk dalam kategori aman karena masih bersifat elastis. Tetapi ketika defleksi yang terjadi pada poros lebih dari 3,8354 mm, poros akan mengalami kegagalan karena pembebanan yang diterima poros bersifat dinamis atau berulang. Peristiwa ini disebut kegagalan fatigue.
=================================================================
In Heat Recovery Steam Generator (HRSG) system, there is low pressure boiler feed pump which is an important thing in operation system. This pump has a shaft which often got failure. The failure happen around 8 to 10 a year. When the pump is used, shaft receive dynamic load. It cause by external factor like unstable voltage to pump, open and close valve that control water to pump. To find out the effect of dynamic load (transient), software Ansys been used to illustrate situation that happen to shaft. There are 3 kinds of load 17.233 N, 22306 N, and 28025 N. These load is used to know the effect to shaft. Each of load get 20 displacement value. Beside that, in this experiment we know the maximum load and maximum deflection that shaft can handle. According to those force, the highest displacement are 0.0029631 m, 0.0038354 m and 0.0048186 m. Those deflection are still in elastic area. But if shaft’s deflection is more than 3,8354 mm, shaft will fail because of repeating load. This phenomenon is called fatigue failure

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Pompa, Poros, Analisa Getaran, Transien, Pump, Shaft, Vibration Analysis, Transient
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA347 Finite Element Method
Divisions: Faculty of Industrial Technology > Material & Metallurgical Engineering > 28201-(S1) Undergraduate Thesis
Depositing User: ELDWIN - -
Date Deposited: 23 Feb 2017 04:09
Last Modified: 05 Mar 2019 04:17
URI: http://repository.its.ac.id/id/eprint/1874