RANCANG BANGUN SISTEM PENGATUR TEMPERATUR KERJA PENDINGIN RUANGAN MENGGUNAKAN KONTROL LOGIKA FUZZY DENGAN RASPBERRY PI

RADITYA, I GUSTI BAGUS PRASTA (2017) RANCANG BANGUN SISTEM PENGATUR TEMPERATUR KERJA PENDINGIN RUANGAN MENGGUNAKAN KONTROL LOGIKA FUZZY DENGAN RASPBERRY PI. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2212100136-Undergraduate_Theses.pdf]
Preview
Text
2212100136-Undergraduate_Theses.pdf - Published Version

Download (3MB) | Preview

Abstract

Aktivitas kehidupan di kota-kota besar baik di perkantoran, sekolah, universitas maupun tempat tinggal tidak terlepas dari penggunaan pendingin ruangan atau yang biasa disebut air conditioner (AC). AC digunakan untuk mengatur temperatur udara di dalam ruangan agar menjadi nyaman sesuai dengan yang dikehendaki oleh pengguna. Setiap orang memiliki tingkat kenyamanan yang berbeda – beda terhadap temperatur udara, ada beberapa orang yang merasa cukup sejuk, kurang sejuk, hangat terhadap temperatur udara dengan nilai yang sama. AC komersil yang beredar dipasaran memerlukan pengguna untuk mengatur temperatur kerja dari AC, sehingga suhu yang diatur oleh pengguna tersebut belum tentu nyaman untuk orang lain. Pada tugas akhir ini sistem dirancang menggunakan metode kontrol logika fuzzy untuk menentukan temperatur kerja dari AC. Masukan kontrol logika fuzzy berupa jumlah orang dan tingkat aktivitas di dalam ruangan yang dideteksi oleh kamera. Hasil kontrol logika fuzzy berupa temperatur kerja AC mengacu pada standar kenyamanan termal di Indonesia yang dikeluarkan oleh badan SNI. Hasil tersebut akan digunakan sebagai acuan untuk remote control agar dapat mengatur temperatur kerja AC. Hasil pengujian menunjukan bahwa temperatur kerja yang diatur melalui remote control memiliki nilai terendah 21oC dan nilai tertinggi 27oC yang sudah sesuai dengan standar kenyamanan termal yang telah didefinisikan oleh badan SNI dengan jarak maksimal antara sistem dengan AC adalah 4 meter. Sistem yang dirancang diharapkan mampu mengurangi campur tangan manusia dalam pengaturan temperatur kerja AC dan telah dibuktikan bahwa kontrol logika fuzzy dapat digunakan sebagai metode dalam mengatur temperatur kerja AC.

=================================================================

Air conditioner (AC) is commonly used in offices, schools, universities, houses located in big cities. AC is used to regulate the room temperature. Everyone has different level of comfort on temperature. Some people feel comfortable while others feel uncomfortable in the same value of temperature. Users set the working temperature of AC that sometimes uncomfortable to others.
In this final project, a control system is designed to determine the working temperature of AC using fuzzy logic controller. The controller’s inputs are number and activity level of people inside a room detected by a camera. The output of the controller is working temperature based on thermal comfort standard issued by institution of National Standard of Indonesia. The output is used as a reference for the remote control to set the working temperature of AC. The result of this final project shown that the lowest working temperature is 21oC and the highest working temperature is 27oC in accordance with the thermal comfort standard issued institution of National Standard of Indonesia. The maximum distance between the system and AC is 4 meter. The system designed is expected to reduce human intervention in setting the working temperature of AC and has been proven that fuzzy logic controller can be used as method on setting the working temperature of AC.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: pendingin ruangan, kontrol logika fuzzy, remote control, air conditioner, fuzzy logic control
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ223 PID controllers
Divisions: Faculty of Industrial Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: I Gusti Bagus Prasta Raditya
Date Deposited: 24 Feb 2017 08:17
Last Modified: 05 Mar 2019 02:24
URI: http://repository.its.ac.id/id/eprint/2080