Perencanaan Desain Alternatif IPAL Dengan Teknologi Anaerobic Baffled Reactor Dan Anaerobic Filter Untuk Rumah Susun Romokalisari Surabaya

Mahatyanta, Agastya (2016) Perencanaan Desain Alternatif IPAL Dengan Teknologi Anaerobic Baffled Reactor Dan Anaerobic Filter Untuk Rumah Susun Romokalisari Surabaya. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 3312100114-Undergratuate_Theses.pdf]
Preview
Text
3312100114-Undergratuate_Theses.pdf - Published Version

Download (4MB) | Preview

Abstract

Rumah Susun Romokalisari adalah rumah susun yang terletak di kota Surabaya dan berdiri sejak tahun 2015. Walaupun masih termasuk baru, rumah susun ini memiliki beberapa permasalahan dikarenakan tidak adanya pengolahan air limbah grey water yang memadai. Selain itu air buangan dari tangki septik rumah susun yang tidak diolah dapat membahayakan kualitas air tanah di sekitar rumah susun. Oleh karena itu perlu adanya unit pengolahan limbah tambahan untuk mengolah kedua air buangan tersebut. Perencanaan ini memberikan dua alternatif unit yang akan digunakan yaitu Anaerobic Baffled Reactor dan Anaerobic Filter. Kedua unit ini dipilih karena biaya pembangunan dan perawatannya yang murah serta operasionalnya yang mudah, berdasarkan literatur dan penelitian-penelitian sebelumnya. Desain ini diawali dengan mengumpulkan data primer dan sekunder. Data primer yang dipakai adalah data jumlah penghuni, debit air bersih,dan luas lahan yang tersedia. Data sekunder berupa HSPK kota Surabaya tahun 2015. Kemudian dilakukan pengolahan data berupa perhitungan dimensi unit Anaerobic Baffled Reactor dan Anaerobic Filter yang mengacu pada kriteria desain tiap unit IPAL yang terdapat pada literatur serta membuat DED, BOQ, dan RAB tiap unit IPAL termasuk perhitungan anggaran biaya operational and maintenance (OM) masing-masing unit selama waktu operasional 5 tahun. Hasil perhitungan tiap unit IPAL akan dibandingkan dan dipilih unit mana yang cocok untuk digunakan di Rumah Susun Romokalisari.
Hasil perhitungan desain IPAL Anaerobic filter dimensi bak ekualisasi (2,2 m x 1,1 m x 1 m), septic tank kompartemen I (4 m x 2 m x 2 m) kompartemen II (2 m x 2 m x 2 m), AF tiap kompartemen (2 m x 4,5 m x 2 m) sebanyak 4 buah. Perhitungan desain IPAL Anaerobic Baffled Reactor menghasikan dimensi bak
ekualisasi (2,2 m x 1,1 m x 1 m), septic tank (3 m x 2 m x 2 m),
ABR tiap kompartemen (1 m x 2,8 m x 2m) sebanyak 6 buah.
Rencana Anggaran Biaya Unit AF Rp 230.586.289,- biaya OM Rp
4.085.579,-/bulan. Sedangkan Unit ABR Rp144.458.126,-serta biaya OM Rp 4.052.245,-/ bulan. Anaerobic Baffled Reactor
memiliki keunggulan dari segi kebutuhan lahan, efisiensi removal, serta biaya konstruksi dan OM dibandingkan dengan Anaerobic
Filter. Oleh karena itu disimpulkan bahwa unit Anaerobic Baffled
Reactor lebih cocok digunakan di Rumah Susun Romokalisari.
=========================================================
=========================================================
Romokalisari Flats is located at Surabaya City and has been built since 2015. Although this flats is relatively new but this flats have some difficulties that caused by the absence of grey water treatment. Also the untreated septictank discharge water can endanger the quality of ground water. Therefore additional wastewater treatment needs to be built to treat it. This design give two alternatives that will be used, Anaerobic Baffled Reactor and Anaerobic Filter. The two units is chosen because of the cheap construction and operational cost also for easy maintenance, according to the previous research. This design is started by gathering primary and secondary data. Primary data is occupancy data, fresh water flow,and available area. Secondary data is HSPK kota Surabaya year 2015. Then the data is processed by calculating the dimension of Anaerobic Baffled Reactor dan Anaerobic Filter that refer to design criteria from literature also making DED, BOQ, and RAB each of units including operational and maintenance cost for five year range. The result of calculation will be compared and chosen which unit that will be used in the flats. Calculation result of Anaerobic filter: equalization tank dimension (2,2 m x 1,1 m x 1 m), settler tankcompartment I (4 m x 2 m x 2 m) compartment II (2 m x 2 m x 2 m), AF each compartment (2 m x 4,5 m x 2 m) for the total of 4 compartment. Calculation result of Anaerobic Baffled Reactor (2,2 m x 1,1 m x 1 m), settler tank (3 m x 2 m x 2 m), ABR each compartment (1 m x 2,8 m x 2m) for the amount of 6 compartment. Construction
iv
cost of Unit AF Rp 230.586.289,- cost of OM Rp 4.085.579,-
/month. While Unit ABR Rp144.458.126,- along with OM cost of
Rp 4.052.245,-/month. Anaerobic Baffled Reactor have
advantages from area needs, removal efficiency,, also
construction and OM cost compared to Anaerobic Filter.
Therefore it can be concluded that Anaerobic Baffled Reactor is
more suitable to be built in Romokalisari flats.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Air limbah rumah susun, ABR, Anaerobic Filter, black water, grey water
Subjects: T Technology > TD Environmental technology. Sanitary engineering
T Technology > TD Environmental technology. Sanitary engineering > TD646 Sewage--Purification
Divisions: Faculty of Civil Engineering and Planning > Environment Engineering > 25201-(S1) Undergraduate Thesis
Depositing User: - AGASTYA MAHATYANTA
Date Deposited: 29 Mar 2017 05:15
Last Modified: 27 Dec 2018 02:47
URI: http://repository.its.ac.id/id/eprint/2441

Actions (login required)

View Item View Item