Peraturan perencanaan struktur gedung tahan gempa di Indonesia mengalami perkembangan seiring terjadinya gempa besar yang terjadi, dari SNI 1726-2002 direvisi menjadi SNI 1726-2012. Bilamana suatu peraturan gempa terbaru muncul dan diberlakukan, maka hal tersebut mengakibatkan perlunya peninjauan ulang bangunan-bangunan yang sudah berdiri untuk dikaji ulang menggunakan peraturan terbaru. Masalah yang akan ditinjau adalah besar perbedaan gaya gempa yang terjadi antara SNI 1726-2002 dengan SNI 1726-2012, dan bagaimana perilaku struktur bangunan jika dikenakan beban gempa berdasarkan SNI 1726-2002 dengan SNI 1726-2012.
Penelitian ini akan menggunakan bangunan gedung Sala View di Solo untuk mengetahui peningkatan gaya gempa yang terjadi dan kebutuhan tulangan lentur serta tulangan geser berdasarkan SNI 1726-2002 dan SNI 1726-2012. Pemodelan struktur menggunakan program bantu SAP2000 dan membuat dua pemodelan struktur dengan dimensi struktur yang sama namun dengan gaya gempa yang berbeda berdasarkan SNI 1726-2002 dan SNI 1726-2012.
Hasil perbandingan dari respon spektrum untuk nilai Sds bahwa desain berdasarkan SNI 1726-2012 lebih tinggi dibanding SNI 1726-2012. Hal tersebut berdampak pada hasil dari analisa nilai gaya geser dasar (base shear) berdasarkan SNI 1726-2012 meningkat sebesar 18% dibanding SNI 1726-2002. Presentase peningkatan pada elemen balok, gaya dalam meningkat sebesar 22% dan kebutuhan tulangan lentur meningkat sebesar 15,9%. Presentase peningkatan pada elemen kolom, gaya dalam meningkat 33,4% namun dengan luasan tulangan lentur minimum antara SNI 1726-2002 dan SNI 1726-2012 masih memenuhi, maka dapat disimpulkan bahwa dimensi kolom dalam struktur tersebut telalu besar. Anggaran biaya yang dibutuhkan meningkat rata-rata sebesar 18,38%.
======================================================================================================= The regulation of earthquake resistant building structure planning in Indonesia has developed as the increasing of earthquake frequencies lately, from SNI 1726-2002 is revised to SNI 1726-2012. If the new regulation on earthquake emerged and applied, it will cause re-evaluation upon current buildings with the new regulation. The problem that will be evaluated is the difference of earthquake force happened between SNI 1726-2002 and SNI 1726-2012 and how the building structure behave if being exposed by earthquake force based on SNI 1726-2002 and SNI 1726-2012.
This research will use Sala View building in Solo to observe the increasing of earthquake force and the needs of elastic reinforcement and shear reinforcement based on SNI 1726-2002 and SNI 1726-2012. The structure modelling used SAP2000 program and create two model structure using same structure dimension but different earthquake force based on SNI 1726-2002 and SNI 1726-2012.
The comparison result of spectrum response for Sds value based on SNI 1726-2012 is higher than 1726-2012. It makes the result of base shear force value based on SNI 1726-2012 increases 18% compared to SNI 1726-2002. The increasing percentage on block element, the inner force increases 22% and the needs of elastic reinforcement increases 15,9%. The percentage on column element, the inner force increases 33,4%, however using the minimum width of elastic reinforcement between SNI 1726-2002 and SNI 1726-2012 is still sufficient, so it can be concluded that the column dimension in that structure is too big. The budget for the required increased by an average of 18,38%.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: struktur; gempa; SNI 1726-2002; SNI 1726-2012; pemodelan struktur; gaya dalam; respon spektrum; base shear; tulagan lentur
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering)
T Technology > TH Building construction
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22301-(D4) Diploma 4
Depositing User: MUCHAMAD CHADAFFI
Date Deposited: 13 Mar 2017 01:16
Last Modified: 13 Mar 2017 01:16
URI: http://repository.its.ac.id/id/eprint/2957

Actions (login required)

View Item View Item