ANALISA STABILITAS TRANSIEN DAN KOORDINASI RELE PADA SISTEM KELISTRIKAN OFFSHORE PLATFORM HUSKY-CNOOC MADURA LIMITED.

ALWI, M. ANDRI LUDFI FANANI (2017) ANALISA STABILITAS TRANSIEN DAN KOORDINASI RELE PADA SISTEM KELISTRIKAN OFFSHORE PLATFORM HUSKY-CNOOC MADURA LIMITED. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2213105018-Undergraduate_Theses.pdf]
Preview
Text
2213105018-Undergraduate_Theses.pdf - Published Version

Download (2MB) | Preview

Abstract

Sistem kelistrikan pada offshore platform Husky-CNOOC Madura Limited ini berbeda dengan sistem kelistrikan yang ada di darat, karena menggunakan frekuensi 60 Hz dan tegangan suplai 6,6 kV yang kemudian diturunkan dengan stepdown transformer menjadi tegangan 480 V. Sebagian besar beban pada sistem kelistrikan di HCML ini merupakan beban motor yang memiliki daya yang bervariasi.
Sistem starting pada motor-motor yang ada pada offshore platform HCML ini menggunakan sistem starting direct online. Sistem starting direct online tersebut pada motor dengan daya yang besar akan sangat berpengaruh terhadap kondisi transien pada sistem kelistrikannya, dengan demikian analisa stabilitas transien diperlukan untuk mengetahui kondisi transien yang ada.
Sistem proteksi Pada sistem kelistrikan offshore platform HCML ini juga sangat diperlukan apabila terjadi gangguan. Apabila terjadi gangguan maka circuit breaker yang harus trip adalah yang berada pada posisi paling dekat dengan pusat gangguannya, dengan demikian analisa koordinasi rele pada sistem kelistrikan ini juga perlu dilakukan untuk mengetahui sistem proteksi yang ada.
==============================================================================================================
The Electrical system on offshore platforms Husky-CNOOC Madura Limited is different with on ground electrical systems, because it uses the frequency of 60 Hz and supply voltage 6.6 kV which is lowered with stepdown transformer to be voltage 480 V. Most of the load on HCML electrical system are motor load that has varied load.
This starting system on the motors on offshore platform HCML uses direct online starting system. That starting direct online system on motor with huge load will influence transient condition on its electrical system, so that transient stability analysis is needed to know the transient condition.
Protection system on offshore platform HCML electrical system is also needed whenever there is trouble if trouble occurs, the circuit breaker which must trip is the one which is closest to the trouble centre, thus relay coordination analysis on electrical system is also needed to be done in order to know the protection system.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Sistem kelistrikan offshore platform HCML, Stabilitas transien, Koordinasi rele.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3226 Transients (Electricity). Electric power systems. Harmonics (Electric waves).
Divisions: Faculty of Industrial Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: - M ANDRI LUDFI FANANI ALWI
Date Deposited: 26 Jan 2017 06:12
Last Modified: 08 Mar 2019 03:52
URI: http://repository.its.ac.id/id/eprint/3042