Aplikasi Double Pulse LIBS (DP-Libs) Untuk Meningkatkan Sinyal Emisi Pada Libs Spektrometer

Banurea, Dame Peto Marsela (2017) Aplikasi Double Pulse LIBS (DP-Libs) Untuk Meningkatkan Sinyal Emisi Pada Libs Spektrometer. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2412100088-Undergraduate-Thesis.pdf] Text
2412100088-Undergraduate-Thesis.pdf - Published Version
Restricted to Repository staff only

Download (2MB)

Abstract

Sistem pendeteksian dengan keistimewaan seperti: ketepatan, kepekaan, dan kecepatan sangatlah dibutuhkan untuk melakukan proses uji dan pengukuran dengan pasti akan kandungan dari bahan penjejak unsur yang berbahaya dan seringkali terdapat dalam jumlah yang sangat kecil (ppm hingga ppb). Laser Induced Breakdown Spectroscopy (LIBS) merupakan salah satu teknik spektroskopi yang memanfaatkan metode spektroskopi atomik untuk menganalisis berbagai unsur di dalam material (padat, cair, dan gas). Untuk mendeteksi konsentrasi yang sangat kecil, seringkali dihadapi masalah sensitivitas deteksi. Untuk mengakomodasi kekurangan ini, telah dilakukan modifikasi sistem LIBS menjadi LIBS pulsa laser ganda (DP-LIBS) yang telah terbukti dapat meningkatkan sinyal emisi atom dengan komposisi atom yang rendah di dalam material. Di dalam penelitian ini, konfigurasi DP-LIBS ortogonal digunakan untuk melakukan pendeteksian unsur mineral kalsium (Ca) dan besi (Fe) yang terkandung di dalam batu giok hitam. Unsur kalsium dan besi mengalami peningkatan sinyal emisi ketika menggunakan DP-LIBS yaitu berturutan sebesar 15 kali, 37 kali, dan 18 kali ketika digunakan laser pulsa pikosecond dengan energi 12 mJ, 20 mJ, dan 30 mJ. Sementara itu untuk unsur besi
mengalami peningkatan sinyal emisi sebesar 12 kali, 34 kali, dan 6 kali
========================================================================================================================================
========================================================================================================================================
High accuracy and sensitivity as well as fast reponse are the important required characteristics for a detection system in order to be capable to detect and determine the concentration of harmful elements in materials, that are often found in a very small amount (in the order of ppm to ppb). LIBS is an atomic spectroscopic technique that is used to analyze elements in material targets. Problem of low sensitivity, particularly to detect a very small concentration of trace elements, can be overcame using double-pulse LIBS (DP-LIBS). In this research an orthogonal DP-LIBS measurement configuration was adopted. This system was used to detect and analyze mineral contents of Calcium (Ca) and Iron (Fe) in a local black stone. Using DP-LIBS, the signals of the Calcium element can be increased to be 15 times, 37 time, and 18 time for respective picosecond laser pulse energy of 12 mJ, 20 mJ, dan 30 mJ. While signals for the iron the increase of intensity were 12 time, 34 times, and 6 times.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: LIBS Spektrometer, pulsa laser tunggal, pulsa laser ganda, elemen penjejak, konsentrasi rendah
Subjects: Q Science > QC Physics
Divisions: Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis
Depositing User: Users 13 not found.
Date Deposited: 05 May 2017 02:41
Last Modified: 29 Dec 2017 03:45
URI: http://repository.its.ac.id/id/eprint/41215