Optimisasi Pengaturan Kompensasi Daya Reaktif Pada Sistem Tenaga Listrik Menggunakan Multi Tipe Facts Devices Berbasis Improved Gravitational Search Algorithm

-, Purwoharjono (2014) Optimisasi Pengaturan Kompensasi Daya Reaktif Pada Sistem Tenaga Listrik Menggunakan Multi Tipe Facts Devices Berbasis Improved Gravitational Search Algorithm. Doctoral thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
2210301003-Disertation.pdf - Published Version

Download (2MB) | Preview

Abstract

Semakin meningkatnya biaya yang diperlukan untuk membangun saluran transmisi, pusat pembangkit baru dan meningkatnya kebutuhan penggunaan barang-barang elektronika daya merupakan alasan penggunaan FACTS device. FACTS (Flexible AC Transmission System) device merupakan peralatan yang dapat digunakan untuk mengatur dan meningkatkan aliran daya serta kestabilan pada sistem tenaga listrik. Penggunaan FACTS device ini dapat digunakan secara luas pada sistem tenaga listrik, sehingga menjadi lebih fleksibel terhadap pembangkitan dan beban yang bervariasi. Penelitian ini mengembangkan metode berbasis kecerdasan buatan untuk mengatur kompensasi daya reaktif menggunakan multi tipe FACTS device. Metode yang diperbaiki dalam penelitian ini adalah metode GSA. Metode GSA merupakan metode metaheuristik baru yang terinspirasi oleh hukum Newton tentang gravitasi dan gerak massa. Perbaikan metode GSA ini menggunakan LDIW (Linear Decrasing Inertia Weight), FL (Fuzzy Logic) dan IT2FLS (Interval Type 2 Fuzzy Logic System). Perbaikan metode GSA ini dilakukan dengan cara menyesuaikan bobot inersia, yang dapat digunakan untuk mengatur kecepatan partikel pada metode GSA, sehingga dapat meningkatkan performansi metode GSA. Perbaikan metode GSA ini dinamakan Improved GSA (IGSA). Jenis FACTS device yang akan digunakan pada penelitian ini, meliputi: TCSC (Thyristor Controlled Series Capasitor), SVC (Static Var Compensator) dan TCPST (Thyristor Controlled Phase Shifting Transformer). Hasil dari IGSA ini disimulasikan pada multi tipe FACTS devices dan di bagi dalam 5 (lima) model simulasi, yaitu: 1). Simulasi aliran daya sebelum pemasangan FACTS device, 2). Simulasi aliran daya setelah pemasangan TCSC, 3). Simulasi aliran daya setelah pemasangan SVC, 4). Simulasi aliran daya setelah pemasangan TCPST dan 5). Simulasi aliran daya setelah pemasangan SVCTCSC- TCPST. Simulasi dilanjutkan dengan melakukan uji kestabilan tegangan pada setiap bus yang meliputi uji kestabilan tegangan sebelum pemasangan FACTS device dan uji kestabilan tegangan setelah pemasangan FACTS device. Hasil akhir simulasi penelitian ini dapat bermanfaat untuk meminimalkan rugirugi daya pada saluran transmisi, memperbaiki deviasi tegangan dan meminimalkan investasi biaya FACTS device, serta bermanfaat untuk meningkatkan kestabilan tegangan pada sistem tenaga listrik. ==================================================================================== One of the reasons to use FACTS device is the increasing costs required to build a transmission line, the new power plant and the growing need for the use of power electronics goods. FACTS device is an equipment used to regulate and improve power flow and stability in power system. FACTS device can be widely used in the electric power system so that it becomes more flexible on varying generation and load. This study developed a method of artificial intelligence to manage reactive power compensation using a multi type FACTS device. The method used in this study was the method of improved GSA. GSA method is a new metaheuristic method inspired by Newton's laws of gravity and mass motion. Improved GSA uses LDIW (Linear Decrasing Inertia Weight), FL (Fuzzy Logic) and IT2FLS (Interval Type 2 Fuzzy Logic System). This GSA that is improved is used to adjust inertia weight used to control the speed of the particles on the GSA and it is applied to postional change mutation of a new agent so as to improve the performance of the GSA method. This new GSA method is called Improved GSA (IGSA). Types of FACTS device used in this study were TCSC (Thyristor Controlled Series Capacitor), SVC (Static Var Compensator) and TCPST (Thyristor Controlled Phase Shifting Transformer). The results of the IGSA were simulated on multi-type FACTS devices and divided in 5 simulation model namely 1). Power flow simulation before installation of FACTS device, 2). Power flow simulation after installation of TCSC, 3). Power flow simulation after installation of SVC, 4). Power flow simulation after installation TCPST and 5). Power flow simulation after installation of the SVC-TCSC-TCPST. After the simulation of the results of this IGSA was performed, it was then proceeded with voltage stability test on each bus that includes voltage stability test before and after installation FACTS device. Final result of this research simulation can be useful to minimize power loss in the transmission line, repair the voltage deviation and minimize FACTS device cost investment as well as beneficial to improve the voltage stability of the power system.

Item Type: Thesis (Doctoral)
Additional Information: RDE 621.319 Pur o
Uncontrolled Keywords: FACTS device; SVC; TCSC; TCPST; GSA; IGSA
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK201 Electric Power Transmission
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK5105.546 Computer algorithms
T Technology > TS Manufactures > TS167 Costs, Industrial
Divisions: Faculty of Industrial Technology > Electrical Engineering > (S3) PhD Theses
Depositing User: Mrs Anis Wulandari
Date Deposited: 23 May 2017 06:28
Last Modified: 23 May 2017 06:28
URI: http://repository.its.ac.id/id/eprint/41352

Actions (login required)

View Item View Item