Desain Dan Implementasi Kontroler PI Pada Sistem Supervisory Control And Data Acquisition (SCADA) Untuk Sistem Pengaturan Level Independen

Dewantara, Prayudha and Santoso, Tatang Teguh (2014) Desain Dan Implementasi Kontroler PI Pada Sistem Supervisory Control And Data Acquisition (SCADA) Untuk Sistem Pengaturan Level Independen. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
2211030055-2211030091-Non-Degree.pdf - Published Version

Download (2MB) | Preview

Abstract

Pengaturan level merupakan proses yang digunakan untuk menjaga tingkat ketinggian air agar tetap dalam kondisi set point yang telah ditentukan. Dalam penerapannya sistem ini memiliki nilai beban yang berubah-ubah apabila terjadi perubahan pada bukaan valve yang tidak sesuai dengan set point. Perubahan tersebut dapat mengakibatkan keluaran menjadi tidak sesuai dengan yang diinginkan. Oleh karena itu, dirancang sebuah kontroler PI (Proportional ditambah Integral) untuk mengendalikan plant agar dapat menjaga kestabilan kerja dan untuk mempercepat respon. Kontroler PI (Proportional ditambah Integral) dalam sistem ini akan diterapkan pada sistem Supervisory Control And Data Acquisition (SCADA) sebagai sistem pemantauan dan pengontrolan terhadap plant. Dari hasil pengujian, kontroler PI (Proportional ditambah Integral) dapat mengendalikan respon plant yang tidak sesuai dengan nilai set point, nilai rata-rata kesalahan waktu tunak pada implementasi sebesar 1,6% . =============================================================================== Setting the level is a process used to maintain water levels for remain within a predetermined set point conditions. In application of this system has a load rating change when there is a change in the valve opening is not in accordance with the set point. Such changes may result in the output to be not in accordance with the desired Therefore, designed a PI controller (Proportional plus Integral) to control the plant in order to maintain stability and to speed up the response work. PI controller (Proportional plus Integral) in this system will be applied to the system of Supervisory Control And Data Acquisition (SCADA) as a monitoring and control system of the plant. From the test results, the PI controller (Proportional plus Integral) in order to control plant responses that do not correspond to the set point value, the average value of the steady state error at the time of implementation of 1.6%.

Item Type: Thesis (Diploma)
Additional Information: RSE 629.89 Dew d
Uncontrolled Keywords: Kontroler PID; Level; SCADA; Controller PID
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ223_Programmable controllers
Divisions: Faculty of Industrial Technology > Electrical Engineering > (D3) Diploma
Depositing User: Mrs Anis Wulandari
Date Deposited: 29 May 2017 03:32
Last Modified: 29 May 2017 03:32
URI: http://repository.its.ac.id/id/eprint/41395

Actions (login required)

View Item View Item