Studi Eksperimental Pengaruh Variasi Temperatur Dan Debit Thermal Oil Sebagai Heater Generator Terhadap Performansi Mesin Pendingin Difusi Absorpsi R22-Dmf

Aryanto, Denis (2015) Studi Eksperimental Pengaruh Variasi Temperatur Dan Debit Thermal Oil Sebagai Heater Generator Terhadap Performansi Mesin Pendingin Difusi Absorpsi R22-Dmf. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
2112106042-Undergraduate Thesis.pdf - Published Version

Download (4MB) | Preview

Abstract

Sistem pendingin saat ini sudah menjadi salah satu kebutuhan yang sangat penting untuk menunjang berbagai aktifitas manusia seperti kebutuhan dibidang industri, pendidikan, perumahan dan kebutuhan lainnya. Salah satu teknologi pendinginan yang ada saat ini adalah sistem refrijerasi difusi absorpsi atau DAR (Diffusion Absorption Refrigeration). Sistem ini menggunakan generator untuk menjalankan sistemnya sebagai pengganti kompresor pada sistem kompresi uap. Berbeda dengan kompresor, generator membutuhkan input berupa kalor. Besar kecilnya COP (Coefficient of performance) mesin pendingin difusi absorpsi salah satunya dipengaruhi oleh jumlah kalor yang diberikan pada generator. Eksperimen ini bertujuan untuk melakukan analisa unjuk kerja pada mesin pendingin difusi absorpsi sehingga performa mesin dapat meningkat. Eksperimen dilakukan dengan menggunakan mesin pendingin difusi absorpsi yang berada di jurusan Teknik Mesin ITS yang telah dimodifikasi pada bagian sumber panas menggunakan thermal oil sebagai heater generator. Fluida kerja dalam sistem yang digunakan adalah pasangan refrijeranabsorben R22-DMF (Dimethylformamida) dengan konsentrasi massa 60%-40%. Pengambilan data dilakukan dengan 3 variasi viii debit thermal oil yaitu : 6 liter/jam, 8 liter/jam, dan 10 liter/jam. Sedangkan temperatur thermal oil divariasikan sebesar 90ºC, 110ºC dan 130ºC. Dari eksperimen tersebut diperoleh data-data sebagai acuan perhitungan pengaruh variasi temperatur dan debit thermal oil terhadap performansi sistem pendingin difusi absorpsi. Hasil yang didapatkan dari eksperimen ini adalah unjuk kerja terbaik dari sistem difusi absorpsi ini diperoleh nilai COP terbesar 0.612 yang didapatkan pada temperatur thermal oil sebesar 130ºC dengan debit thermal oil sebesar 8 liter/jam. Untuk nilai kapasitas pendinginan ) terbesar diperoleh sebesar 139,1 watt, laju perpindahan panas pada generator ( ) 233 watt, laju perpindahan panas pada kondensor 143 watt, laju alir massa refrijeran 0.000721 kg/s serta efisiensi generator 0,233 yang didapatkan pada temperatur thermal oil sebesar 130ºC dan debit 6 liter/jam. ============================================================================================ Refrigeration systems nowadays have become one of the most important need to support human activities such as industrial, educational, residential etc. One of the refrigeration technology that still exist is Diffusion Absorption Refrigeration (DAR). The system used the generator to start the system as a substitute for compressor in vapour compression system. Different with compressor, the generator need amount of heat to start. Coefficient of performance (COP) of this system mostly influenced by number of heat that supplied to the generator. This experiment is used to analyze the performance of diffusion absorption refrigeration system so the performance can be improved. The experiment used diffusion absorption refrigeration system at mechanical engineering department of ITS that has modified so it can use thermal oil as heater generator. The working fluids used in this system are refrigerant-absorbent pair R22-DMF (Dimethylformamida) with 60%-40% mass concentration. Data decision did with 3 variations of fluid flow, 6 litre/hour, 8 litre/hour and 10 litre/hour. Thermal oil temperature varied into 90ºC, 110ºC and 130ºC. From this experiment we x gained datas as reference for performance calculation of this system. The result that can be obtained from this experiment is the best performance for this diffusion absorption refrigeration system gained the highest COP 0.612 from 130ºC thermal oil temperature and 8 litre/hour fluidflow. It is also obtained that cooling capacity ( ) is 139,1 watt, heat transfer rate of generator ( ) is 233 watt, heat transfer rate of condenser ( ) is 143 watt, mass transfer rate of refrigerant is 0.000721 kg/s and generator efficiency is 0,233 that all gained from 130ºC thermal oil temperature and 6 litre/hour fluidflow

Item Type: Thesis (Undergraduate)
Additional Information: RSM 621.56 Ary s
Uncontrolled Keywords: Difusi Absorpsi, DAR, COP, R22-DMF, Heater Generator.
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ223_Programmable controllers
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1318 Geothermal Power Plants
Divisions: Faculty of Industrial Technology > Mechanical Engineering > (S1) Undergraduate Theses
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 09 Jun 2017 03:41
Last Modified: 09 Jun 2017 03:41
URI: http://repository.its.ac.id/id/eprint/41557

Actions (login required)

View Item View Item