Fachrullah, Almas (2015) Sistem Pengendalian Tegangan Keluaran Pada Inverter Buck Boost Satu Fasa Dengan Induktor Penyangga Menggunakan Metode Sliding Mode Control. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
2411100076-Undergraduate Thesis.pdf - Published Version Download (2MB) | Preview |
Abstract
Inverter merupakan salah satu komponen terpenting pada pembangkit daya listrik terdistribusi (Distributed Generator-DG system), dengan tugas utama mengubah tegangan DC menjadi AC. Ada banyak topologi inverter, salah satunya adalah Inverter buck boost satu fasa dengan induktor penyangga (IBBSF-IP). Kelebihan dari IBBSF-IP jenis ini adalah dapat menghasilkan nilai tegangan keluaran hampir 5 kali tegangan masukan. Sliding Mode Control(SMC) merupakan salah satu metode kontrol yang banyak digunakan pada sistem pengendalian converter, inverter, motor maupun sistem robotika. SMC memiliki sifat robust yaitu insensitif terhadap perubahan parameter. Tugas Akhir ini akan membahas implementasi kontrol SMC pada IBBSF-IP secara simulasi menggunakan perangkat lunak Simulink MATLAB R2009A dan Power simulator versi 9.0.3. Pengujian sistem dilakukan secara open loop, closed loop dan sensitifitas dengan parameter tegangan input dan beban yang divariasikan. Pada uji open loop dengan tegangan sumber 60 Volt, IBBSF-IP menunjukkan grafik tegangan keluaran berbentuk gelombang sinusoidal dengan amplitudo maksimum mendekati 400 Volt. Pada uji closedloop grafik tegangan keluaran IBBSF-IP dapat dikontrol untuk mengikuti setpoint dengan menggunakan metode kontrol SMC orde 2 dengan nilai %Ess terkecil pada 311 Volt yaitu 1.02%. Pada uji sensitifitas sistem dengan memvariasikan nilai tegangan masukan dan nilai resistansi didapat bahwa semakin besar perubahan kedua parameter tersebut dari nilai referensi maka nilai sensitivitas akan semakin kecil, dengan nilai sensitivitas terkecil 0.29 jika terjadi perubahan tegangan masukan 32% dan 0.0002 jika terjadi perubahan resistansi sebesar 3700% .
===============================================================================================
Inverter is one of the most important thing on Distributed Generator System (DG System), with the main task is to convert from DC Voltage to AC Voltage. Tthere are many type of inverter, Single Phase Buck Boost Inverter with Buffer Inductor (SPBBI-BI) is one of them. The advantage of SPBBI-BI is it has an output voltage five times higher than input voltage. Sliding Mode Control (SMC) is one of the control method that often used in control of Converter, Inverter, Motor and robotic system. SMC has a robust behavior that insensitif to parameter change. This Final Project enlight about implementation of SMC control in SPBBI-BI through simulation in Simulink MATLAB R-2009A and Power Simlutaor Version 9..0.3. System tested in 3 ways which is open loop, closed loop and sensitivity test. On the open loop test with 60 volt input voltage, SPBBI-BI has sinusoidal output voltage and the amplitude aproximately at 400 volt. On the closed loop test, SPBBI-BI well being controlled according to setpoint feed on orde 2 SMC with minimum 1.02% Ess at 311 Volt Setpoint. On the Sensitivity test which is vary the value of input voltage and Resistance load, system sensitivity became lower if change in 2 parameter getting higher, with minimum sensitivity is 0.29 if input voltage change 32% and 0.00002 if resistance change 3700%.
Item Type: | Thesis (Undergraduate) |
---|---|
Additional Information: | RSF 629.831 2 Fac s |
Uncontrolled Keywords: | Inverter, IBBSF-IP,SMC |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ223 PID controllers T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3226 Transients (Electricity). Electric power systems. Harmonics (Electric waves). T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK7872 Electric current converters, Electric inverters. |
Divisions: | Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis |