Putra, Bagus Adi Mulya (2016) Evaluasi Korosi Pada Bagian Luar Tube HRSG Dan Metode Pencegahannya (Studi Kasus PLTGU PT.PJB UP Gresik). Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
2113105023-Undergraduate-Thesis.pdf - Published Version Download (2MB) | Preview |
Abstract
Heat Recovery Steam Generator (HRSG) merupakan
suatu alat yang berfungsi menaikkan efisiensi turbin gas pada
pembangkit listrik. PT PJB unit Gresik memiliki beberapa HRSG
yang sering mengalami korosi pada pipanya. Penelitian ini
membahas korosi pada permukaan luar pipa untuk mencari
penyebab dan cara pencegahannya.
Dalam penelitian ini digunakan metode Root Cause
Failure Analysis (RCFA) untuk menentukan penyebab kerusakan
akibat korosi. Data yang digunakan adalah pola operasi HRSG,
bahan bakar, emisi gas buang, treatment pada HRSG dan analisa
sampel sisi luar tube yang terkorosi.
Siklus mati hidup HRSG yang sangat tergantung pada
kebutuhan daya listrik masyarakat merupakan penyebab utama
korosi. Saat HRSG dimatikan dalam waktu yang lama, korosi
terjadi pada permukaan fin tube HRSG oleh acid dew point
karena sulfur yang terkandung bahan bakar turbin gas.
Disarankan untuk melakukan preservasi menggunakan
dehumidifikasi untuk menurunkan kelembaban agar kerusakan
akibat korosi bisa dihindari.
==================================================================================================================
Heat Recovery Steam Generator (HRSG) is an equipment
to increase efficiency of gas turbine in power plant. PT.PJB
GRESIK has some HRSG which have severe corrosion at outer
surface its tube. This research focus in finding the cause of the
problem and how to prevent it.
Root Cause Failure Analysis (RCFA) methode is used to
find cause and damage result by corrosion. The RCFA methode
that used are observe operation pattern of HRSG, type of fuel
consumed, exhaust gas emission, prevention treatment of HRSG
and XRD analysis of the corroded Pre-heater tube sample.
On-off cycle of the HRSG, that depend on power demand,
is the main cause corrosion. When HRSG was off for a long
period of time, corrosion could attack fin tube surface due to acid
dewpoint. Sulfur is from the gas turbine fuels. It was sugested that
preservaton with dehumidifier should be done to reduce moisture
to prevent the corrosion in HRSG chamber.
Item Type: | Thesis (Undergraduate) |
---|---|
Additional Information: | RSM 620.112 23 Put e |
Uncontrolled Keywords: | HRSG, korosi tube, RCFA, Dehumidifikasi |
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Divisions: | Faculty of Industrial Technology > Mechanical Engineering > 21201-(S1) Undergraduate Thesis |
Depositing User: | Users 13 not found. |
Date Deposited: | 22 Jun 2017 06:36 |
Last Modified: | 27 Dec 2018 04:23 |
URI: | http://repository.its.ac.id/id/eprint/41823 |
Actions (login required)
View Item |