Studi HAZOP Berbasis Layer Of Protection Analysis Pada Regeneration Tower 32-R-104 Continous Catalytic Regeneration Naptha Process Unit PT. Pertamina

Asty, Rinanda Dwi Purnama (2016) Studi HAZOP Berbasis Layer Of Protection Analysis Pada Regeneration Tower 32-R-104 Continous Catalytic Regeneration Naptha Process Unit PT. Pertamina. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2412100018-Undergraduate-Theses.pdf]
Preview
Text
2412100018-Undergraduate-Theses.pdf

Download (2MB) | Preview

Abstract

Salah satu sektor industri yang sangat vital di Indonesia adalah
industri minyak dan gas. Kecelakaan yang terjadi pada suatu
industri terutama industri oil and gas tentunya akan menimbulkan
kerugian cukup besar dan pada kasus yang lebih berbahaya
mungkin saja dapat memakan korban. Studi ini bertujuan untuk
memberikan rekomendasi berdasarkan perhitungan SIL dan
penilaian resiko dengan analisis HAZOP untuk mencapai
keselamatan kerja dari suatu industri proses. Objek yang akan
dianalisis terkait resiko dan nilai Safety Integrity Level adalah
regeneration tower CCR Naptha Process Unit PT Pertamina RU
VI Balongan. Seluruh line input proses yang memberikan pengaruh
besar terhadap jalannya sistem regeneration tower memiliki resiko
bahaya dengan tiga kategori risk ranking yaitu 15,38 % untuk
kategori rendah, 38,46 % untuk kategori medium, dan 46,15 %
untuk kategori tinggi. Perhitungan nilai SIL yang telah dilakukan
dengan metode Layer of Protection Analysis menunjukkan angka
SIL 0 untuk seluruh loop sistem yang mewakili jalannya proses.
Rekomendasi berupa kombinasi dari konfigurasi arsitektur SIS
dapat dilakukan untuk menaikkan nilai SIL 0 menjadi SIL 1 dengan
memberikan kombinasi konfigurasi yang sama untuk sensing
element dan final element yaitu 1oo2.

===================================================================================

One of the vital industrial sectors in Indonesia is the oil and
gas industry. Accidents that occur in an oil and gas industry will
certainly lead to substantial losses and for more dangerous
condition might lead to some major injuries. This study intends to
provide recommendations based on the calculation of risk
assessment with SIL and HAZOP analysis to reach the safety of an
industrial process. The analyzed object is a regeneration tower
CCR Naphtha Process Unit PT Pertamina RU VI Balongan. The
whole process inputs that influence the course of regeneration
tower system has a risk of danger defined into three categories of
risk ranking which are 15.38 % for the category of low, 38.46 %
for the category of medium, and 46.15 % for the category of high.
SIL value calculation has been done by the method of Layer of
Protection Analysis that shows SIL 0 for the entire loop system that
represents the course of the process. Recommendations in the form
combination of SIS architecture configuration can be done to raise
the value of SIL 0 to SIL 1 by providing a combination of the same
configuration for the sensing element and final element which is
1oo2.

Item Type: Thesis (Undergraduate)
Additional Information: RSF 620.86 Ast s
Uncontrolled Keywords: HAZOP; Layer of Protection Analysis; SIL
Subjects: T Technology > T Technology (General) > T55 Industrial Safety
Divisions: Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis
Depositing User: Anis Wulandari
Date Deposited: 05 Jul 2017 03:47
Last Modified: 26 Dec 2018 06:39
URI: http://repository.its.ac.id/id/eprint/41872