Rancang Bangun Sistem Pengaturan Suhu Ruangan Berdasarkan Suhu Tubuh Menggunakan Termometer Inframerah

Mohamed, Danang Rizki (2016) Rancang Bangun Sistem Pengaturan Suhu Ruangan Berdasarkan Suhu Tubuh Menggunakan Termometer Inframerah. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2210100023-Undergraduate-Thesis.pdf]
Preview
Text
2210100023-Undergraduate-Thesis.pdf - Published Version

Download (1MB) | Preview

Abstract

Pesatnya perkembangan pada teknologi Air-Conditioner (AC) memberikan banyak kemudahan bagi para pengguna beserta dengan fasilitas-fasilitas yang ditawarkan para produsen AC. Namun kurangnya pengetahuan para pengguna akan kesesuaian suhu tubuhnya dengan suhu pada AC menyebabkan ketidaknyamanan yang dirasakan dalam tubuh pengguna. Sehingga dibutuhkan pengaturan secara otomatis pada suhu AC yang sesuai berdasarkan pada suhu tubuh manusia saat itu.
Penggunaan Termometer Infrared yaitu thermopile infrared sensor, sebagai sensor yang membaca suhu pada tubuh manusia, diharapkan dapat mengatur keluaran suhu pada air-conditioner agar sesuai dengan suhu tubuh manusia disaat itu. Berdasarkan pada rule based yang dibangun menggunakan Fuzzy Logic, dapat diketahui hubungan input-output antara suhu tubuh manusia dan suhu keluaran pada air-conditioner. Presentase keberhasilan adalah 83%.
==================================================================================================================
The advance growth of air-conditioner technology gives the easiest way for users with the facilities that have been given from air conditioner maker. Due to the lack of knowledge of the users about the suitable body temperature with the actual AC temperature make an uncomfortable condition for them. Therefore, the automatic control of AC is needed to make a suitable AC temperature for body at that time.
The use of infrared thermometer, which is thermopile infrared sensor, as a sensor that detect and read the human’s body temperature, hoped can controlling the tempereature output on air conditioner in order to make a good balance with the body temperature at that time. Based on the Rule Based which is established by using fuzzy logic, it can be known the relation between input-output on air conditioner. Percentage of success is 83%.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 629.892 Moh r
Uncontrolled Keywords: air-conditioner, fuzzy logic, termometer infrared.
Subjects: Q Science > QC Physics > QC271 Temperature measurements
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Industrial Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Users 13 not found.
Date Deposited: 06 Jul 2017 08:06
Last Modified: 27 Dec 2018 02:58
URI: http://repository.its.ac.id/id/eprint/41904