Pembuatan Alternator Axial Flux Coreless Dengan Menggunakan Magnet Permanen

Sitorus, Clarissa Amelia (2017) Pembuatan Alternator Axial Flux Coreless Dengan Menggunakan Magnet Permanen. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 1113100116-Undergraduate_Theses.pdf]
Preview
Text
1113100116-Undergraduate_Theses.pdf - Published Version

Download (2MB) | Preview

Abstract

Telah dilakukan penelitian pada alternator aksial dengan magnet permanen dimana penelitian ini bertujuan menghitung effisiensi berdasarkan hasil perhitungan secara teoritis maupun secara percobaan. Rotor magnet permanen menggunakan 12 magnet neodymium dengan 6 koil sebagai stator. Generator aksial ini diputar dengan motor pada kecepatan berbeda (360; 482; 482,7; 485,1; 485,3; 485,9). Dari hasil pengukuran didapatkan hasil pada 3 koil maupun 6 koil dapat menghasilkan tegangan yang sebanding dengan kecepatan putarnya. Untuk kecepatan terendah 360 rpm didapatkan 5,8 Volt pada 3 koil sedangkan 13,8 Volt pada 6 koil dengan arus yang sama sebesar 2,5 Ampere. Perhitungan tegangan juga dilakukan secara teoritis berdasarkan parameter fisik dan studi literatur. Perbedaan hasil perhitungan dengan hasil pengukuran rata – rata 22%. Perhitungan effisiensi generator dilakukan dengan membandingkan daya output generator dengan daya output motor penggerak. Hasil pada generator 3 koil memiliki effisiensi tertinggi 28,75 % sedangkan 6 koil sebesar 62,083 %. Dari penelitian ini didapatkan kesimpulan bahwa generator aksial magnet permanen akan memiliki effisiensi yang cukup tinggi dengan semakin banyak koil dan semakin cepat putarannya.
================================================================== Research has been done on the alternator axial with permanent magnet where this research aims to calculate efficiencies based on the results of the theoretically calculation and in the experiment. The Rotor permanent magnet using 12 neodymium magnet with 6 coil stator. This axial generator coupled with motor on different speed (360; 482; 482,7; 485,1; 485,3; 485,9). From the measurement result, we obtained the results on 3 coil and 6 coil can produce voltage linear with its speed. For lowesr speed 360 rpm obtained 5,8 volt on 3 koil while 13,8 Volts on 6 koil with the same current at 2,5 Ampere. The calculation of the voltage also done theoretically based on the physical parameters and literature study. the difference in the calculation with the measurement result average was 22%. The calculation for generator efficincies done by comparing generator output power and drive motor output power.This result is for 3 coil generator has 28,75 % efficiencies while for 6 coil has 62,083 %. From this researches we can get conclusion that axial permanent magnet generator efficiencies will be more coil and higher speed.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Effisiensi, Magnet Permanen, Rotor, RPM, Stator
Subjects: Q Science > QC Physics
Divisions: Faculty of Mathematics and Science > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: CLARISSA AMELIA SITORUS
Date Deposited: 28 Sep 2017 03:04
Last Modified: 05 Mar 2019 06:34
URI: http://repository.its.ac.id/id/eprint/42965