Perusahaan Daerah Air Minum (PDAM) Kota Blitar melayani sekitar 38.160 jiwa dari total jumlah penduduk Kota Blitar 145.111 jiwa. Cakupan pelayanan PDAM sebesar 26% (2016), dengan keterangan 6.360 pelanggan yang aktif dari 11.940 sambungan terpasang. PDAM Kota Blitar saat ini sedang melaksanakan program menyambut 10.000 sambungan tahun 2019 untuk meningkatkan cakupan pelayanan. Dalam penelitian ini dilakukan analisis pada jaringan primer dan sekunder eksisting untuk mendapatkan kondisi sistem sebagai dasar peningkatan pelayanan. Peningkatan pelayanan dilakukan dengan analisis real demand survei yang bertujuan untuk mengetahui faktor yang mempengaruhi masyarakat agar berlangganan kembali. Analisis sistem menggunakan EPANET, yang mensimulasi jaringan sehingga didapatkan output berupa headloss, kecepatan aliran, dan sisa tekan.
Empat puluh satu pipa memiliki kecepatan aliran kurang dari 0,3 m/s berpotensi terjadi endapan suspended solid (Fe dan Mn) yang menyebabkan penyempitan pipa. Penyempitan ini akan meningkatkan headloss sistem sehingga dapat menurunkan tekanan air (terjadi pada blok 1, 2, 19, 20, 23 dan 24) yang menyebabkan air tidak dapat mengalir ke pelanggan. Pemasangan pipa paralel pada pipa yang memiliki headloss lebih dari 20 m ternyata dapat menurunkan headloss dan meningkatkan tekanan air. Peningkatan pelayanan, sumur bor masih dapat menampung debit peningkatan tahap 1 sebesar 130l/s dan tahap 2 sebesar 150l/s. Sistem perpipaan masih mampu digunakan untuk pengembangan tersebut.
Pelanggan mengharapkan pihak PDAM Kota Blitar agar melakukan perbaikan terutama terkait dengan tingkat kejernihan air, bau dan rasa air. PDAM perlu mengolah air sumur bor karena Fe dan Mn yang tinggi.
=================================================================
Regional Water Company (PDAM) Blitar municipality serves drinking water about 38,160 people from the total population of Blitar municipality about 145,111 people. The coverage of PDAM service around 26% (2016), with 6,360 active subscribers from 11,940 installed connections. PDAM Blitar municipality is currently implementing a program to welcome 10,000 connections by 2019 to improve service coverage. In this research, we analyze the primary and secondary networks to obtain the condition of the system as the base of service improvement. The improvement of service is done by real demand survey analysis which is aimed to know the factors that influence the community to be re-subscribe. System analysis using EPANET program, this program will simulate the network and get the output of headloss, flow velocity, and press rest.
Forty one pipes have flow velocity less than 0.3 m/s of potentially suspended solid sedimentation which causes narrowing of diameter. Narrowing of diameter will increase the system headloss so that it can lower the water pressure in the pipe. The small water pressure causes water to not flow to customers. Installation of parallel pipes in pipes that have more than 20 m headloss turns down headloss and increases water pressure. improvement of the service, the deep wells can still accommodate the uprating debit of phase 1 increase of 130 l/s and phase 2 of 150 l/s. And the distribution system is still possible to flow through the uprating debit.
Customers expect the company to make improvements, especially related to the level of water clarity, smell, and taste of water supply. PDAM need to process deep well water containing high Fe and Mn.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Sistem Distribusi, Air Minum, PDAM, Kota Blitar, Distribution System, Drinking Water, Blitar City, EPANET
Subjects: T Technology > TD Environmental technology. Sanitary engineering
Divisions: Faculty of Civil Engineering and Planning > Environment Engineering > 25201-(S1) Undergraduate Thesis
Depositing User: Ichwan Rahmawan Widodo
Date Deposited: 13 Nov 2017 02:17
Last Modified: 05 Mar 2019 07:41
URI: http://repository.its.ac.id/id/eprint/43168

Actions (login required)

View Item View Item