Kristyanti, Arlyna (2017) Modifikasi Perencanaan Struktur Gedung Office Biliton Surabaya dengan Menggunakan Kolom Rectangular Concrete Filled Steel Tube (RCFT) dan Balok Octagonal Castellated. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
3115105064-Undergraduate_Theses.pdf - Published Version Download (12MB) | Preview |
Abstract
Gedung Office Biliton merupakan gedung yang pada awalnya menggunakan struktur beton bertulang. Sebagai bahan studi perancangan bangunan ini di modifikasi menggunakan struktur baja menggunakan kolom Rectangular Concrete Filled Steel Tube (RCFT) dan balok Octagonal Castellated dengan sistem dinding geser plat baja (Steel Plate Shear Wall). Dinding geser plat baja (Steel Plate Shear Wall) adalah sebuah sistem penahan beban lateral yang terdiri dari plat baja vertikal padat yang menghubungkan balok dan kolom di sekitarnya yang terpasang sepanjang ketinggian struktur sehingga membentuk sebuah dinding penopang. Tujuan tugas akhir ini adalah diharapkan dapat menjadi rekomendasi untuk proyek-proyek selanjutnya yang ada di Indonesia agar dapat memanfaatkan material baja sebagai bahan struktur gedung dengan pertimbangan keuntungan penggunaan material baja sebagai struktur utama gedung.
Untuk menghasilkan perencanaan struktur baja yang rasional, maka perencanaan ini mengacu pada peraturan-peraturan yang berlaku diantaranya SNI 1726:2012 tentang Tata Cara Perencanaan Tahan Gempa Untuk Bangunan Gedung dan Non Gedung, SNI 1729:2015 tentang Spesifikasi untuk Bangunan Gedung Baja Struktural, SNI 1729:2015 tentang Tata Cara Perencanaan Struktur Baja untuk Bangunan Gedung, SNI 2847:2013 tentang Persyaratan Beton Struktural Untuk Bangunan Gedung, dan SNI 1717:2013 tentang Beban Minimum Untuk Perancangan Bangunan Gedung dan Struktur Lain, PPIUG 1983 tentang Peraturan Pembebanan Indonesia Untuk Gedung. Penggambaran hasil perhitungan struktur dalam bentuk Gambar Teknik dilakukan dengan menggunakan program bantu AutoCAD.
Dari analisa dan hasil perhitungan diperoleh hasil yaitu: tebal pelat atap, lantai dan parkir 9 cm. Dimensi balok gedung Office Biliton adalah CB 712,5.300.11.15 and CB 710.200.10.16 pada lantai 1-7, CB 710.200.10.16 and CB 627,5.300.10.15 pada lantai 8-14, CB 627,5.300.10.15 and CB 562,5.300.9.14 pada lantai 15-21, dan CB 495.250.8.12 and CB 432,5.200.9.14 pada lantai atap. Sedangkan dimensi kolom utama menggunakan RCFT HSS 700.700.22.22 pada lantai G-5, RCFT HSS 650.650.22.22 pada lantai 6-10, RCFT HSS 600.600.22.22 pada lantai 11-14, RCFT HSS 550.550.22.22 pada lantai 15-18, dan RCFT HSS 500.500.22.22 pada lantai 19-lantai atap. Dimensi dinding geser pelat baja memiliki ketebalan 4 mm. Serta perencanaan sambungan digunakan baut mutu fub = 8250 MPa. Perencanaan pondasi menggunakan bored piles dengan diameter Ø60 cm and Ø80 cm.
=================================================================
Biliton Office is a building that initially has designed using reinforced concrete structures. As study material building design is modified to a steel structure with rectangular concrete filled steel tube as coloumn and octagonal castellated beam as beam with steel plate shear wall system. Steel plate shear wall is a lateral load resisting system consisting of a solid steel plate vertical connecting beams and columns around which installed along the height of the structure so as to form a buttress. The purpose of this final project was made in the hope can be a recommendation for future projects in Indonesia to take advantage of the steel material as the material structure of the building with consideration of the advantages of using steel materials as the main structure of the building.
To produce the structural design of steel rational, then this plan refers to the rules that apply include SNI 1726: 2012 on Procedures Planning Earthquake for Building and Non Building, SNI 1729: 2015 on Specifications for Buildings Structural Steel, SNI 1729 : 2002 on Procedures for Steel Structural Design for Buildings, PPIUG 1983 on Indonesian Loading Regulation for Building, and SNI 1727: 2013 on Minimum Load for Planning Building and Other structures. Earthquake load is calculated by the method of dynamic response spectrum earthquake load, and then analyzed using computer aids program SAP2000 and using AutoCAD for drawing design structures and arcitecht.
From analysis and the calculation results, the roof plate, floor plate and car port plate thickness is 9 cm. Dimensional beam of Biliton Office on 1st-7th floor is CB 712,5.300.11.15 and CB 710.200.10.16, on 8th-14th floor is CB 710.200.10.16 and CB 627,5.300.10.15, on 15th-21st floor is CB 627,5.300.10.15 and CB 562,5.300.9.14,and on roof floor is CB 495.250.8.12 and CB 432,5.200.9.14. While the dimensions of the main column on G-5th floor is RCFT HSS 700.700.22.22, on 6th-10th floor is RCFT HSS 650.650.22.22, on 11th-14th floor is RCFT HSS 600.600.22.22, on 15th-18th floor is RCFT HSS 550.550.22.22, and on 19th-roof floor is RCFT HSS 500.500.22.22. Dimensions of steel plate shear wall has a thickness of 4 mm. As well as planning to use bolt connection quality fub = 8250 MPa. Planning of foundation using bored piles Ø60 cm and Ø80 cm.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | struktur baja, balok kastela, kolom komposit, dinding geser plat baja, steel design, castellated beam, composite coloumn, steel plate shear wall |
Subjects: | T Technology > TH Building construction > TH437 Building--Cost control. |
Divisions: | Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis |
Depositing User: | Arlyna Kristyanti . |
Date Deposited: | 20 Nov 2017 06:42 |
Last Modified: | 06 Mar 2019 04:45 |
URI: | http://repository.its.ac.id/id/eprint/43876 |