Desain Peralatan Diagnostik Motor Induksi Berbasis Tegangan Surja Untuk Mengetahui Pengaruh Rotor Terhadap Hasil Pengujian Tes Surja Menggunakan Metode Error Area Ratio(EAR))

Anshori, Muhammad Farid (2017) Desain Peralatan Diagnostik Motor Induksi Berbasis Tegangan Surja Untuk Mengetahui Pengaruh Rotor Terhadap Hasil Pengujian Tes Surja Menggunakan Metode Error Area Ratio(EAR)). Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2215105034-Undergraduate-Theses.pdf]
Preview
Text
2215105034-Undergraduate-Theses.pdf - Published Version

Download (3MB) | Preview

Abstract

Salah satu kegagalan yang sering terjadi pada motor induksi adalah kegagalan dari isolasi stator. Penyebab dari kegagalan isolasi ini dapat disebabkan karena beberapa faktor diantaranya pengaruh panas,listrik,mekanik, dan juga pengaruh lingkungan. Kegagalan dari isolasi stator disebabkan oleh isolasi antar belitan stator yang melemah. Melemahnya isolasi antar belitan stator dapat menyebabkan degdradasi pada belitan hingga akhirnya terjadi kegagalan isolasi pada seluruh belitan. salah satu cara untuk mengetahui kekuatan isolasi antar belitan adalah menggunakan tes surja.
Namun kebanyakan tes surja dilakukan tanpa menggunakan rotor atau dengan kata lain pada saat melakukan tes surja rotor dilepas. Seharusnya sebuah tes dilakukan berdasarkan kondisi aktual yang ada dilapangan. bagaimanapun juga dimungkinkan perbedaan yang signifikan pada tes surja apabila tes dilakukan dengan menggunakan rotor dan tanpa menggunakan rotor. Maka dari itu penting untuk mengetahui dan memahami bagaimana pengaruh dari rotor terhadap hasil tes surja. Untuk itu tugas akhir ini bertujuan untuk mengetahui pengaruh dari rotor terhadap hasil surja tes. Pengujian akan dilakukan dengan menggunakan rotor dan menganalisa bagaimana pengaruh posisi rotor terhaadap terhadap hasil tes surja. Pada tugas akhir ini menggunakan metode EAR dalam proses analisa hasil gelombang surja
=================================================================
One of the frequent failures in induction motors is failure of stator isolation. The cause of this isolation failure can be caused by several factors such as heat, electrical, mechanical, and environmental influences. Failure of stator isolation is caused by the isolation between stator windings that are weakened. The weakening of isolation between the stator windings can cause degradation of the winding until finally there is failure of isolation in all entanglement. One way to know the power of isolation between winding is to use the surge test.
However, most surge tests are performed without the use of a rotor or in other words when performing a removable rotor surge test. A test should be performed based on actual conditions in the field. However, there may be significant differences in surge tests if tests are performed using rotor and rotor implantation. It is therefore important to know and understand how the effect of rotor on surge test results. For this final project aims to determine the effect of the rotor on the results of the test surge. The test will be conducted using the rotor and analyzing how the rotor position affects against the surge test results. In this final project use EAR method in process of surge wave result analysis

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Tes Surja, motor induksi,pengaruh rotor, Surge Test, Motor Induction, Influence of Rotor
Subjects: T Technology > TL Motor vehicles. Aeronautics. Astronautics
Divisions: Faculty of Industrial Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Muhammad Farid Anshori
Date Deposited: 06 Oct 2017 07:34
Last Modified: 08 Mar 2019 06:17
URI: http://repository.its.ac.id/id/eprint/44117

Actions (login required)

View Item View Item