Perancangan Pencahayaan Buatan di Aula B.G. Munaf ITS

Nugraheni, Tutut (2017) Perancangan Pencahayaan Buatan di Aula B.G. Munaf ITS. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2413100049_Undergraduate_Thesis.pdf]
Preview
Text
2413100049_Undergraduate_Thesis.pdf - Published Version

Download (5MB) | Preview

Abstract

Kebutuhan pencahayaan diperoleh dari pencahayaan alami (matahari) dan buatan ataupun kombinasi keduanya. Pencahayaan buatan terdiri dari lampu, lilin dan lampu minyak. Pencahayaan buatan dalam suatu ruangan sangat dibutuhkan apabila pencahayaan alami tidak mampu memberikan tingkat pencahayaan sesuai standart yang ada. Penelitian dilakukan untuk mengetahui sesuai atau tidaknya kuat pencahayaan buatan di Aula B.G. Munaf ITS berdasarkan SNI 03-6575-2001 dan akan dilakukan perancangan pencahayaan buatan menggunakan simulasi software DIALux 4.13. Untuk mendapatkan tingkat pencahayaan pada Aula B.G.. Munaf digunakan Luxmeter dengan membuat dahulu grid 36 petak. Tingkat pencahayaan Aula B.G.. Munaf didapatkan sebesar 123 lux, dimana nilai tersebut masih kurang dari standar yang sebesar 200 lux. Pada simulasi keadaan asli dibuat semirip mungkin dengan kondisi ruangan dan pada perancangan diberikan nilai reflektansi (dinding, langit-langit dan lantai) dan variasi lampu agar mendapatkan tingkat pencahayaan yang sesuai. Didapatkan 4 simulasi yang mendekati berdasarkan kuat pencahayaan, jumlah lampu, daya total dan nilai keseragaman, yaitu Perancangan pertama dengan lampu Philips DN570B PSED-E 1XLED20S/830 C dengan 2200 lumen sebanyak 30, tingkat pencahayaan 213 lux. Perancangan keempat dengan lampu Philips WT460C L700 1XLED19S/840 WB 1928 lumen 32 buah, kuat pencahayaan 208 lux. Perancangan ketujuh dengan menggunakan 34 lampu Philips BBS415 W15L120 1XLED24/840 MLO-PC-N 1700 menghasilkan 201 lux. Perancangan kesebelas dengan 20 lampu Philips 4MX800 L600 2XLED20-4000 P30 3700 lumen menghasilkan 197 lux. Untuk daya lampu total per satuan luas ruangan masih bagus yaitu tidak melebihi daya maksimum sebesar 25 watt/m2.
======================================================================================================
Lighting requirements are obtained from natural (sun) and artificial lighting or a combination of both. Artificial lighting consists of lamps, candles and oil lamps. Artificial lighting in a room is needed if natural lighting is not able to provide the level of lighting according to the standard. The research was conducted to find out whether or not strong artificial lighting in B.G.. Munaf Hall ITS based on SNI 03-6575-2001 and will be done artificial lighting design using software simulation DIALux 4.13. To get the lighting level in B.G.. Munaf Hall used Luxmeter by first making a grid of 36 plots. Lighting level in “B.G. Munaf” Hall was obtained at 123 lux, where the value is still less than standard of 200 lux. In the simulation the actual situation is made as closely as possible with the condition of the room and The design is given the reflectance value (wall, ceiling and floor) and the variation of the lamp to get the appropriate lighting level. Four simulations are approached based on the level of illumination, number of lamp, total power, and uniformity values are The first design with 30 Philips DN570B PSED-E 1XLED20S/830 C 2200 lumen, lighting level 213 lux. The fourth design with 32 Philips WT460C L700 1XLED19S/840 WB 1928 lumen, lighting level 208 lux. The seventh design with 34 Philips BBS415 W15L120 1XLED24/840 MLO-PC-N 1700 lumen , lighting level 201 lux. The eleventh design with 20 Philips 4MX800 L600 2XLED20-4000 P30 3700 lumen, lighting level 197 lux and .For total power of lamps per unit area of the room are still good because no more than the maximum power of 25 watt/m2.

Item Type: Thesis (Undergraduate)
Additional Information: RSF 621.322 551 Nug p-1
Uncontrolled Keywords: perancangan pencahayaan, pencahayaan buatan, pencahayaan buatan hemat energi
Subjects: Q Science
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis
Depositing User: Nugraheni Tutut
Date Deposited: 02 Feb 2018 03:02
Last Modified: 08 Mar 2019 02:26
URI: http://repository.its.ac.id/id/eprint/45584