Bahari, Muhammad Rizky Fajar (2017) Evaluasi Struktur Gedung One East Residences di Wilayah Gempa Tinggi Sesuai SNI 03-1726-2012 dan Metode Pelaksanaan Kolom dan Dinding Geser. Diploma thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
3113041083-Undergraduate_Theses.pdf - Published Version Download (5MB) | Preview |
Abstract
Indonesia merupakan salah satu negara berkembang di
dunia dengan tingkat perkembangan penduduk yang tinggi.
Tingginya kepadatan penduduk tersebut mendorong adanya
pembangunan yang berkaitan dengan kebutuhan akan tempat
tinggal dengan lahan yang terbatas. Pembangunan hunian
bertipe vertical seperti Apartemen merupakan sebuah solusi yang tepat jika diperuntukkan untuk perkotaan. Pada gedung tinggi dan multi-stories, beberapa masalah dapat timbul akibat adanya gempa, seperti contoh besarnya periode getar struktur gedung, maupun besarnya simpangan antar lantai yang terjadi akibat gempa. Oleh karenanya perlu adanya perlakuan dan analisa khusus terhadap gedung tinggi dan perilakunya terhadap gaya gempa. Berdasarkan hasil analisa, evaluasi, dan trial and error terhadap struktur gedung One East Residences, diperoleh hasil bahwa tidak semua elemen-elemen struktur primer seperti balok, kolom serta dinding geser masih mencukupi dari segi kapasitasnya dalam menahan gaya yang terjadi. Pada elemen kolom, aksial yang terjadi masih belum memenuhi sehingga diperlukan adanya pemotongan lantai. Lalu, pada beberapa elemen balok, momen yang terjadi melebihi kapasitasnya. Pada elemen Shearwall, persyaratan mengenai komponen batas khusus tidak memenuhi persyaratan sesuai SNI 2847-2013.
Selain dari segi kapasitas, pada analisa dinamis struktur gedung One East Residences, periode getar struktur melebihi batas atas yang diisyaratkan oleh SNI 1726-2012 untuk gedung dengan sistem struktur ganda. Hasil analisa struktur menggunakan SAP2000, diperoleh periode getar sebesar 4.2 detik, sedangkan batas atas
sesuai persyaratan SNI 1726-2012 adalah 2,7 detik untuk gedung dengan sistem struktur ganda. Usulan modifikasi pada gedung One East Residences adalah berupa demolisi lantai, untuk mengetahui seberapa kaku struktur jika beban gravitasi dan lantai berkurang, sesuai dengan
persyaratan SNI 1726-2012. Dengan menggunakan program
bantu SAP2000, diperoleh hasil optimum jumlah lantai gedung one east dalam respon dinamisnya adalah 13 lantai. Hasil dari evaluasi ini dituangkan dalam bentuk gambar dengan menggunakan program bantu AUTOCAD, dan tabel rekapitulasi kapasitas penampang.
======================================================================
Indonesia is one of the developing countries in the world with high population growth rate. The high population density encourages development related to the need for shelter. A vertical –dwelling like apartments building is one of the best solutions for any urban areas. However, on high rise and multi - stories building, some problems may occur due to the effect of earthquake, for example the fundamental periods that relatively high, also the lateral deformation that become too large due to effect of earthquake. Therefore, it’s necessary to have some treatments and analysis for high rise building and its behavior due to earthquake. Based on analysis, evaluation and trial and errors of One East Residences’s building structures. Its found that not all primary structural elements such as beams, columns and shear walls are sufficient in terms of their capacity to withstand the force. For columns, the axial load is larger than its capacities, which means it requires the stories to be demolished. For beams, the bending moment is larger than
its capacities. For shear walls, the special boundary elements does not fulfil any requirements - which hinted by SNI 2847-2013. In addition to capacity, on thedynamic analysis of One East Residences building structures, the fundamental periods of One East Residences are far too large than its upper limit which is hinted by SNI 1726-2012 for building with dual-system. The structural results using SAP 2000 shows that the fundamental periods of the building is around 4,2 second while its upper limit is only at 2,75 second. The structural modification suggested for One East Residences is structural demolition. This modification will show us how rigid the structure if any gravity loads and stories are demolished according to any requirements hinted by SNI 1726-2012. From SAP 2000 analysis results, the optimum stories for One East Residences building is only 13 stories. The results of this structural evaluation will be drawn with AUTOCAD, with summary tables which informed any structural capacities.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Evaluasi, Gempa, Gedung Tinggi, Stabilitas, Trial and Errors |
Subjects: | T Technology > TH Building construction |
Divisions: | Faculty of Vocational |
Depositing User: | Muhammad Rizky Fajar Bahari |
Date Deposited: | 04 Oct 2017 02:00 |
Last Modified: | 08 Mar 2019 04:19 |
URI: | http://repository.its.ac.id/id/eprint/46119 |
Actions (login required)
View Item |