Desain Modifikasi Struktur Golden Tulip Essensial Hotel Menggunakan Metode Flat Slab

Rachmawati, Ririn Rosdiana (2017) Desain Modifikasi Struktur Golden Tulip Essensial Hotel Menggunakan Metode Flat Slab. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 3115105022-Undergraduated_Thesis.pdf]
Preview
Text
3115105022-Undergraduated_Thesis.pdf - Published Version

Download (10MB) | Preview

Abstract

Gedung “Golden Tulip essensial Hotel” direncanakan dibangun pada zona gempa tinggi yang terdapat di kota Semarang. Desain awal dari hotel ini adalah beton bertulang dengan 8 Lantai yang berada di Bojonegoro. Namun pada tugas akhir ini dilakukan beberapa modifikasi perencanaan. Perencanaan menggunakan struktur flat slab dengan dikombinasikan dengan dinding geser yang berfungsi sebagai struktur penahan gaya lateral. Struktur atas pada bangunan ini meliputi kolom, balok tepi, dan drop panel. Sedangkan struktur bawah menggunakan pondasi tiang pancang.
Struktur flat slab digunakan secara luas pada bangunan gedung karena beberapa kelebihan dalam aspek struktural maupun arsitektural. Lantai yang didapatkan lebih luas dan tinggi, tidak perlu finishing dengan plafond, hemat biaya proyek karena dapat mengurangi pemakaian bekesting pada elemen balok dan juga pada pemakaian beton. Namun struktur flat slab ini sendiri juga terdapat kelemahan, antara lain pada hubungan pelat-kolom , dimana tegangan geser tidak mampu ditahan hanya dengan kolom. Oleh karena itu, memperlebar luas geser pelat dapat dilakukan dengan mempertebal pelat. Namun hal tersebut menyebabkan pelat tidak ekonomis. Solusinya dengan menggunakan drop panel. Drop panel merupakan penebalan pelat di daerah kolom sebagai kekuatan geser penahan gaya geser pons yang cukup besar pada daerah hubungan pelat-kolom.
Dalam tugas akhir ini, secara keseluruhan direncanakan dengan Sistem Rangka Gedung (SRG) karena dalam perencanaannya bangunan ini terletak pada zona gempa tinggi sehingga seluruh beban lateral akan dipikul oleh dinding struktur yang telah tercantum pada SNI 03-1726-2012 yang membatasi penggunaan struktur flat slab lebih spesifik. Dari analisa dan hasil perhtiungan diperoleh hasil, yaitu tebal flat slab 25 cm , dimensi drop panel 300x300x12 cm, dimensi balok tepi 35/50 cm, dimensi kolom lantai 1-4 dengan 90/90 , lantai 5-9 dengan 80/80 dan lantai 10-13 dengan 70/70 , tebal shearwall 40 cm dan terdapat 4 tipe. Perencanaan pondasi menggunakan tiang pancang spun pile 60 cm dengan kedalaman 16 m.

=================================================================================

The "Golden Tulip Essensial Hotel" building is planned to be built in the high seismic zone in Semarang. At first design of this hotel is a reinforced concrete with 8 Floors located in Bojonegoro. But in this final project there are some design modification. This building planed using a flat slab structure and combine with a shear wall that serves as a lateral force brace structure. The upper structures in this building are including columns, eksterior beams, and drop panels. And the bottom structure using spun pile.
The flat slab structure used in buildings because there are advantages in structural and architectural aspects. The floors are more spacious and high, dont need finishing with ceiling, cost-effective project because it can reduce the use of formwork on beam elements and also on the use of concrete. However, the flat slab structure also has weaknesses such as in the column-plate joint, where the shear stress can be detained only by the column. Therefore, widening the shear width of the plate can be done by thickening the plate. But it causes the plate is not economical. The solution is by using the drop panel. The drop panel is the thickening of the plate in the column area as a shear force counter in the column-plate joint area.
In this final project, it is planned with Building Frame System (SRG) because in the planning design of this building is located in high earthquake zone, so that all lateral load will be carry by the shear wall which is on SNI 03-1726-2012 limiting the use of flat slab structure more specific. From the analysis and the results of calculation obtained design, flat slab is 25 cm thickness, drop panel dimension is 300x300x12cm, eksterior beam dimension is 35/50 cm, column dimension for 1-4 floor is 90/90, 5-9 floors is 80/80 and 10- 13 is 70/70, shearwall is 40 cm thickness and there are 3 types. Design planning for the foundation is using spun pile piles 60 cm with a 16 m of depth.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Dinding Struktural , Drop Panel , Flat Slab, Gaya Geser, Gempa.
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering)
T Technology > TA Engineering (General). Civil engineering (General) > TA681 Concrete construction
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: Ririn Rosdiana Rachmawati
Date Deposited: 10 Oct 2017 02:19
Last Modified: 08 Mar 2019 02:37