Pada dasarnya dalam pengoperasian gardu portal konvensional masih memiliki kendala yaitu dari segi keamanannya. Hal ini dikarenakan tidak adanya pengaman pada gardu ketika dioperasikan secara manual serta tidak terdapat pendeteksian tegangan ketika petugas telah melakukan pemadaman gardu ketika dilakukan pemeliharaan. sehingga berpostensi dapat membahayakan operator. Berdasarkan kondisi tersebut maka dibuatlah "Sistem Pelaporan Pengoperasian Gardu Portal Konvensional Satu Fasa dalam Kondisi Pemeliharaan". Alat ini terdiri dari mikrokontroller Arduino yang dihubungkan dengan sensor peak detektor, modem GSM SIM 900, modul bluetooth HC-05, dan RTC. Data dari mikrokontroller yang terhubung dengan sensor peak detektor dan RTC akan dikirim ke android untuk dimonitoring dengan memanfaatkan media bluetooth HC-05, sehingga kondisi dari saklar relai dan tegangan output yang terdapat pada gardu dapat dipantau oleh operator PLN serta dilaporkan ke operator pusat menggunakan media SMS. Pelaporan tersebut akan mengirimkan SMS berupa kondisi dari gardu setelah dioperasikan oleh operator dan ketika gardu terjadi gangguan.
Dari tugas akhir yang dibuat, alat tersebut dapat melakukan monitoring kondisi dari saklar relai, tegangan outpout pada prototipe gardu, dan RTC. Sedangkan berdasarkan hasil pengujian dengan alat, kapasitas modul bluetooth HC-05 untuk mengirimkan data adalah maksimal 7 meter serta untuk pelaporan kondisi gardu alat ini dapat mengirimkan SMS dengan rata-rata waktu 14,50 detik. Hal ini tergantung dari baik buruknya sinyal provider yang digunakan.
===========================================================================
Basically in the operation of conventional portal substations has a problem with its security. This is because there is no safety at the substation when operated manually and there is no voltage detector when the officer has extinguished the substation during maintenance so it can endanger the operator. Based on these conditions then it is made "Reporting System Conventional Portal Substations One Phase In Maintenance Conditions". This tool consists of an arduino microcontroller connected to a peak detector sensor, GSM SIM 900 modem, HC-05 bluetooth module, and RTC. Data from microcontroller that connected with peak detector and RTC sensors will be sent to android for monitoring with bluetooth HC-05. So, the conditions of relay switch and the output voltage in substation can be monitored by operator PLN and reported to central operator using SMS. That reporting will send SMS conditions from substation after operated by operator and when substation happened problem.
From the final project has been created, that tool can monitor condition of relay switch, output voltage on substation prototype, and RTC. While based on the test results with the tool, capacity of HC-05 bluetooth module to transmit data maximum is 7 meters and for reporting substation condition of this tool can send SMS with average time of 14.50 seconds. This depends on both the bad signal provider is used.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Gardu Konvensional, Modem GSM SIM900, SOP (Standart operating procedure) |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK201 Electric Power Transmission |
Divisions: | Faculty of Vocational > 36304-Automation Electronic Engineering |
Depositing User: | Lutfi Kurnia Hilmy |
Date Deposited: | 09 Feb 2018 04:07 |
Last Modified: | 06 Mar 2019 02:36 |
URI: | http://repository.its.ac.id/id/eprint/46627 |
Actions (login required)
View Item |