Rancang bangun sistem pengendalian level pada mixing tank proses degumming mini plant biodiesel di workshop instrumentasi

Yuarifaldi, Renza (2017) Rancang bangun sistem pengendalian level pada mixing tank proses degumming mini plant biodiesel di workshop instrumentasi. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2414031032-Non_Degree.pdf]
Preview
Text
2414031032-Non_Degree.pdf - Published Version

Download (3MB) | Preview

Abstract

Telah dirancang dan dibuat sistem pengendalian level dengan menggunakan sensor ultrasonik HC-SR04 yang berfungsi dalam mengetahui level (ketinggian) pada mixing tank di proses degumming. Cara kerja dari sistem pengendalian level ini adalah sensor ultrasonik HC-SR04 memberikan input pada 2 solenoid valve untuk membuka atau menutup. Set point yang digunakan 3 cm, untuk menutup solenoid valve pada tangki minyak dan membuka solenoid valve pada tangki katalis. Pada set point 9 cm, untuk menutup solenoid valve pada tangki katalis dan mengaktifkan motor mixer. Dari pengujian sensor yang telah dilakukan, diketahui bahwa pembacaan dari sensor terkadang terdapat error paling besar yaitu 0,056 cm. Pengujian sensor dilakukan untuk mengetahui karakteristik statik dan nilai ketidakpastian dari sensor. Untuk mencari nilai ketidakpastian dari sensor, dilakukan suatu pengukuran pada sensor dan menggunakan penggaris standar untuk pembandingnya. Dari hasil pengukuran yang telah dilakukan, diketahui nilai dari ketidakpastian diperluas (Uexp) sebesar 0,756.

===================================================================

It has been designed and made level control system by using ultrasonic sensor HC-SR04 which function in know level (height) at mixing tank in degumming process. The workings of this level control system is the ultrasonic sensor HC-SR04 provides input on 2 solenoid valve to open or close. Set point used 3 cm, to close the solenoid valve on the oil tank and open the solenoid valve on the catalyst tank. At set point 9 cm, to close the solenoid valve on the catalyst tank and activate the motor mixer. From testing the sensors that have been done, it is known that the readings of the sensors sometimes have the biggest error of 0.056 cm. Sensor testing is performed to determine the static characteristics and uncertainty values of the sensor. To find the uncertainty value of the sensor, a sensor is measured and using a standard ruler for comparison. From the measurements that have been done, it is known that the value of uncertainty is extended (Uexp) of 0.756

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Sensor ultrasonik HC-SR04, Sistem Pengendalian Level, solenoid valve.
Subjects: T Technology > TP Chemical technology
T Technology > TP Chemical technology > TP156 Crystallization. Extraction (Chemistry). Fermentation. Distillation. Emulsions.