Analisa hasil Pengukuran Koordinat Terrestrial Laser Scanner GLS 2000

Setiawan, Alif Fariqa'an (2018) Analisa hasil Pengukuran Koordinat Terrestrial Laser Scanner GLS 2000. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 3513100098-Undergraduate_Theses.pdf]
Preview
Text
3513100098-Undergraduate_Theses.pdf - Accepted Version

Download (2MB) | Preview

Abstract

TLS (Terrestrial Laser Scanner) merupakan salah satu alat yang digunakan untuk mengakuisisi data dengan cara memindai permukaan obyek, yang dapat diaplikasikan pada pemodelan 3D, perhitungan volume dan pengukuran terestris. Dalam penelitian ini dilakukan analisa data pengukuran koordinat TLS dengan ETS (Electronic Total Station). Pada proses pelaksanaannya, penelitian ini dilakukan pada dua ruangan yang memiliki ukuran dan dimensi yang berbeda, yaitu Ruang I dan Ruang II. Akuisisi data ETS dilakukan dengan melakukan proses pengukuran koordinat pada target yang telah tersebar didalam ruangan. Sedangkan untuk akuisisi data TLS dilakukan dengan melakukan pemindaian pada setiap ruangan yang telah tersebar targetnya. Selisih nilai koordinat dari data TLS dengan ETS dianggap sebagai nilai kesalahan sistematis.
Dari hasil penelitian menunjukkan bahwa untuk Ruang I memiliki nilai RMS error koordinat X sebesar 0,004 m, koordinat Y sebesar 0,005 dan untuk koordinat Z sebesar 0,011 m. Sedangkan untuk Ruang II memiliki nilai RMS error koordinat X sebesar 0,003 m, koordinat Y sebesar 0,004 dan untuk koordinat Z sebesar 0,005 m. Hal ini menunjukkan bahwa pengukuran TLS di kedua ruangan pada posisi planimetris sedikit terpengaruh oleh ukuran dan dimensi, yang mengakibatkan selisih sebesar 1 mm. Sedangkan pada posisi elevasi memiliki pengaruh yang cukup signifikan yang menghasilkan selisih sebesar 6 mm.
===========================================================================================================
TLS (Terrestrial Laser Scanner) is one of tools that used to acquire data by scanning the surface of the object, which can be applied to 3D modeling, volume calculation, terrestrial measurement and many more. This study will be analyzed data of TLS coordinate measurement, using data from ETS (Electronic Total Station). This study was conducted on two rooms that have different sizes and dimensions, namely Room I (room 104 of Geomatics Engineering of ITS) and Room II (Office room of PT ASABA Surveiing). ETS data is taken by coordinate measurement process on the target that has been spread in the room. While TLS data is taken by doing a scan on that room. The difference coordinate values between TLS and ETS is considered a sistematic value.
The result of this study indicate that for Room I have RMS error coordinate equal to coordinate X equal to 0.004 m, coordinate Y equal to 0.005 m and for coordinate Z equal to 0.011 m. While for Room II has RMS error coordinate value equal to coordinate X of 0.003 m, coordinate Y of 0.004 m and for coordinates Z of 0.005 m. This indicates that TLS measurements in both rooms in the planymetric position are slightly affected by size and dimensions, resulting in a difference of 1 mm. While the elevation position has a significant influence that produces a difference of 6 mm.

Item Type: Thesis (Undergraduate)
Additional Information: RSG 526.982 Set a-1 3100018074544
Uncontrolled Keywords: Kesalahan Sistematis, Terrestrial Laser Scanner, Electronic Total Station.
Subjects: Q Science > QC Physics > QC851 Coordinates--Measurement.
T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering)
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Geomatics Engineering > 29202-(S1) Undergraduate Thesis
Depositing User: Setiawan Alif Fariq'an
Date Deposited: 07 Mar 2018 07:06
Last Modified: 11 Jul 2020 08:49
URI: http://repository.its.ac.id/id/eprint/49686