Pengaruh Vented-Box Terhadap Thiele-small Parameter Loudspeaker

Putrie, Widiyana (2018) Pengaruh Vented-Box Terhadap Thiele-small Parameter Loudspeaker. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01111340000089-Undergraduate_Theses.pdf]
Preview
Text
01111340000089-Undergraduate_Theses.pdf - Accepted Version

Download (3MB) | Preview

Abstract

Pengujian loudspeaker biasanya dilakukan dengan thiele- small parameter. Studi vented-box loudspeaker bertujuan untuk mengetahui pengaruh vented-box terhadap kualitas loudspeaker melalui thiele-small parameter loudspeaker. Penelitian dilakukan dengan mengukur karakteristik loudspeaker berupa frekuensi respon, impedansi dan thiele small parameter pada vented-box dan panel. Salah satu faktor yang mempengaruhi parameter akustik tersebut adalah nilai kompresi udara yang dihasilkan oleh bagian loudspeaker atau yang biasa disebut compliance udara. Pada vented-box terdapat pengaruh dari compliance udara yang terkompresi di dalam box dan udara yang masuk dari lubang port yang berakibat mempengaruhi karakteristik murni loudspeaker. Sementara pada panel, tidak terjadi adanya kompresi udara. Dari hasil pengukuran dan analisa, diperoleh nilai rasio compliance udara dari box adalah sebesar 8,29 : 10,7. Nilai ini berdampak pada faktor kerugian box. Kerugian respon vented-box mencapai
0,63% sedangkan untuk panel sebesar 0,014%. Kerugian yang besar terjadi pada vented-box yang diakibatkan oleh bentuk desain enclosure dan material peredam di dalamnya.

=========================================================================================================

Loudspeaker testing is usually done with thiele-small parameter. Vented-box to see the effect of loudspeaker quality through thiele-small parameters on vented-box boxes. Research carried out by measuring the characteristics of response frequency loudspeaker, impedance and thiele small parameters in vented- boxes and panels. One of the factors affecting the acoustic parameters is the compressed air value generated by the loudspeaker or so-called air compliance. In vented-boxes there is the effect of compressed air compliance in the box and the incoming air from the port hole causing the pure loudspeaker sound trigger. While on the panel, does not happen no compressed air. From the measurement and analysis results, the ratio of compliance from box is 8,29 : 10,7. This value have impact to the losses of vented-box. The losses of vented-box is
0.63% than the losses on the panel is 0,014%. The losses of the enclosure are caused by the shape of the enclosure design and the damping material in it.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Loudspeaker, Frekuensi Respon, Impedansi, Thiele Small Parameter, Vented-box
Subjects: Q Science
Divisions: Faculty of Mathematics and Science > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Widiyana Puspita Putrie
Date Deposited: 11 Apr 2018 01:56
Last Modified: 16 May 2018 06:49
URI: http://repository.its.ac.id/id/eprint/50619

Actions (login required)

View Item View Item