Studi Eksperimen Perbandingan Performansi Sistem Water Chiller Menggunakan Refrigeran R-22 Dan Musicool-22

Pambudi, Andi (2018) Studi Eksperimen Perbandingan Performansi Sistem Water Chiller Menggunakan Refrigeran R-22 Dan Musicool-22. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02111545000004-Undergraduate_Theses.pdf]
Preview
Text
02111545000004-Undergraduate_Theses.pdf - Accepted Version

Download (2MB) | Preview

Abstract

Water chiller adalah mesin refrigerasi yang menggunakan metode pendinginan secara tidak langsung, dimana proses pendinginannya menggunakan dua refrigeran yaitu refrigeran primer dan refrigeran sekunder. Refrigeran adalah zat kerja utama yang digunakan untuk menyerap dan mengalirkan kalor dalam sistem refrigerasi. Refrigeran yang digunakan dalam hal ini yaitu R-22 dan MC-22. Media yang didinginkan adalah air, dimana air dengan temperatur tinggi dan debit konstan mengalir dan melewati evaporator yang berisi refrigeran, air yang telah melewati evaporator akan mengalami penurunan temperatur dikarenakan panas pada air diserap oleh refrigeran pada evaporator.
Pemilihan refrigeran dalam hal ini tidak hanya mempertimbangkan sifat termodinamikanya, tetapi juga nilai Global Warning Potential (GWP) dan Ozone Depletion Potential (ODP). Refrigeran yang merupakan zat kerja utama memiliki pengaruh pada kerja kompresor dan efek refrigerasi pada evaporator. Penelitian ini bertujuan untuk menganalisa performasi dari sistem water chiller dan kebutuhan energi pada kompresor dengan menggunakan refrigeran yang berbeda yaitu R-22 dan MC-22. Selanjutnya dari penelitian ini akan diukur temperatur dan tekanan dari masuk dan keluarnya kompresor, kondensor, evaporator dan alat ekspansi tiap refrigeran. Pengukuran dilakukan untuk mendapatkan hasil energy yang dibutuhkan kompresor, efisiensi kerja kompresor, banyaknya kalor yang diserap oleh refrigeran di evaporator, kalor yang dilepas pada kondensor, dan coefficient of performance (COP) dari tiap refrigeran.
Dari hasil analisa ini akan diperoleh suatu sistem refrigerasi dengan performasi yang paling baik dengan kebutuhan kerja kompresor yang sedikit, serta sistem refrigerasi yang ramah lingkungan adalah yang menggunakan MC-22 baik menggunakan beban low, medium, dan high. Nilai COP dengan beban low 2.425; medium 2.579; high 2.880 dan kebutuhan kerja kompresor lebih rendah dengan nilai low 1.081kW ; medium 1.148kW ; high 1.274kW dibandingkan menggunakan R-22. ============== Water chiller is a refrigeration machine that uses indirect cooling method, where the cooling process uses two refrigerant that is primary refrigerant and secondary refrigerant. Refrigerant is the main working substance used to absorb and exert heat in the refrigeration system. The refrigerant used in this case is R-22 and Musicool-22. The cooled medium is water, where water with high temperature and constant discharge flow through the evaporator containing the refrigerant, the water that has passed through the evaporator will decrease the temperature due to the heat in the water absorbed by the refrigerant in the evaporator.
The choice of refrigerant in this case not only consider its thermodynamic properties, but also the value of Global Warming Potential (GWP) and Ozone Depletion Potential (ODP). The refrigerant which is the main working substance has an influence on the compressor work and the refrigeration effect on the evaporator. This study aims to analyse the performance of the water chiller system and the energy needs of the compressor by using different refrigerants, R-22 and MC-22. From this research will be measured temperature and pressure from enter and exit of compressor, condenser, evaporator and expansion valve of each refrigerant. Measurements are made to obtain the required energy output of the compressor, the working efficiency of the compressor, the amount of heat absorbed by the refrigerant in the evaporator, the heat released on the condenser, and the coefficient of performance (COP) of each refrigerant.
From this analysis we will get a refrigeration system with the best performance with little energy consumption, environmentally friendly refrigeration system that uses MC-22 using low, medium, and high load. COP value with low load 2.425; medium 2.579; high 2.880 and compressor working consumption value is lower with a low value of 1.081kW; medium 1.148kW; high 1.274kW compared to using R-22.

Item Type: Thesis (Undergraduate)
Additional Information: RSM 621.564 Pam s
Uncontrolled Keywords: Water chiller; Refrigerant; R-22; MC-22; coefficient of performance.
Subjects: Q Science > QC Physics > QC271 Temperature measurements
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK4035.R4 Refrigeration and refrigerating machinery
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21201-(S1) Undergraduate Thesis
Depositing User: Andi Pambudi
Date Deposited: 24 Apr 2018 02:49
Last Modified: 10 Aug 2020 07:44
URI: http://repository.its.ac.id/id/eprint/50993

Actions (login required)

View Item View Item