Studi Rekonfigurasi Jaringan Dan Penentuan Lokasi Distributed Generation (DG) Pada Sistem Distribusi Radial 3 Phasa Metode Newton Rhapson Untuk Meningkatkan Keluaran Daya Aktif DG

Mahendra, Surya (2015) Studi Rekonfigurasi Jaringan Dan Penentuan Lokasi Distributed Generation (DG) Pada Sistem Distribusi Radial 3 Phasa Metode Newton Rhapson Untuk Meningkatkan Keluaran Daya Aktif DG. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
2213105082-Undergraduate Thesis.pdf - Published Version

Download (12MB) | Preview

Abstract

Aliran daya merupakan suatu hal yang sangat penting dalam perencanaan dan desain sistem tenaga. Informasi yang utama dari aliran daya adalah magnitude dan sudut phasa dari tegangan pada masingmasing bus serta aliran daya aktif pada masing-masing saluran. Newton- Raphson merupakan salah 1 metode untuk mengatasi aliran daya dari susunan persamaan non liniear yang terdapat matriks bus admitansi (Ybus) dengan 2 atau lebih variable. Suatu jaringan memiliki data saluran dan data bus yang membentuk suatu konfigurasi tertentu. Pada kenyataannya, konfigurasi tersebut belum mampu untuk meningkatkan keluaran daya yang diinginkan. Penempatan lokasi distributed generation (DG) dan konfigurasi ulang perlu dilakukan dengan tujuan keluaran daya tersebut menjadi aktif. Studi rekonfigurasi jaringan dan penentuan lokasi distributed generation (DG) pada sistem distribusi radial 3 phasa metode newton rhapson merupakan solusi dari permasalahan tersebut. Hasil yang diharapkan tugas akhir ini dalam bentuk sebuah program load flow jaringan distribusi aktif. Keluaran tersebut dapat digunakan untuk analisis jaringan distribusi radial sehingga dapat membantu dalam peningkatan keluaran daya aktif DG. ======================================================================================================== The power flow is something that is very important in the planning and design of power systems. The main information of the power flow is magnitude and phase angle of the voltage on each bus as well as active power flow in each channel. Newton-Raphson is one method to overcome the power flow of the composition of non-linear equations contained bus admittance matrix (Ybus) with 2 or more variable. A network has a data channel and a data bus that forms a particular configuration. In fact, the configuration has not been able to increase the power output desired. Placement location of distributed generation (DG) and reconfiguration needs to be done with the purpose of the power output becomes active. Study reconfiguration of the network and determining the location of distributed generation (DG) on 3-phase distribution system radial rhapson newton method is a solution to these problems. The expected result of this thesis in the form of a distribution network load flow program is active. The output can be used for analysis of radial distribution network so as to assist in the improvement of active power output DG.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 621.31 Mah s
Uncontrolled Keywords: Aliran Daya, 3 Phasa, Rekonfigurasi Jaringan, DG,Distribusi Radial.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK201 Electric Power Transmission
Divisions: Faculty of Industrial Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 17 Apr 2018 02:42
Last Modified: 24 Aug 2018 03:44
URI: http://repository.its.ac.id/id/eprint/51748

Actions (login required)