Abstract

Kebutuhan energi listrik indonesia semakin meningkat. 90% pembangkit listrik di Indonesia masih menggunakan fossil fuel. Diperlukan energi alternatif lainnya, salah satunya adalah energy angin. Turbin angin Savonius merupakan salah satu jenis turbin angin VAWT (vertical axis wind turbine). Kemampuan Self Starting turbin Savonius cocok digunakan di daerah perkotaan dimana kecepatan anginnya kurang dari 10 m/s. Daya yang dihasilkan oleh turbin dikarenakan perbedaan besar torsi pada returning blade dan advancing blade. Tetapi efisiensi turbin ini masih rendah. Tujuan dari penelitian ini adalah meningkatkan performa turbin dengan menambahkan penghalang didepan returning blade berbentuk silinder.
Untuk mencapai tujuan tersebut, penelitian ini dilakukan dengan variasi letak silinder penghalang tegak lurus terhadap arah datangnya angin dengan diameter sudu (y/D) dan variasi bilangan Reynolds. Variasi (y/D) yaitu 0, 0,25, 0,5 dan variasi Reynolds number 97000, 145000 dan 178000. Tahap dalam melakukan penelitian ini adalah pertama, memasang alat dan melakukan setting alat. Lalu mengambil data temperatur. Setelah itu nyalakan blower dan set kecepatan hingga Reynolds Number 97000. Kemudian mengambil data torsi dinamis dan torsi statis. Mencatat hasil dan ulangi pecobaan hingga Reynolds Number 178000. Setelah pengambilan data, blower dimatikan dan menambahkan penghalang silinder sirkular pada y/D sama dengan 0 lalu lakukan pengambilan data dengan tahapan sama
ii
dengan tanpa penghalang. Tahap pengambilan data di ulang pada posisi penghalang y/D 0,25 dan 0,5
Dari hasil eksperimen didapatkan performa turbing angin Savonius tanpa menggunakan pengghalang memiliki Coefficient of Power maximum pada bilangan Reynolds 97000 sebesar 15,6 %, pada bilangan Reynolds 145000 mempunyai Coefficient of Power sebesar 13,3% dan pada bilangan Reynolds 178000 mempunyai nilai Coefficient of Power sebesar 8,5 %. Jika ditambahkan Silinder pengganggu didepan returning blade Coefficient of Power mengalami kenaikan. Penambahan silinder pengganggu paling efektif diletakkan pada posisi y/D 0,5. Pada bilangan Reynolds 97000 terjadi kenaikan sebesar 1,3%dari nilai tanpa penghalang, pada bilangan Reynolds 145000 terjadi kenaikan sebesar 12% sedangkan pada bilangan Reynolds 178000 terjadi kenaikan sebesar 6,8% dari nilai Coefficient of Power tanpa penghalang.
=========================================================================================
Indonesia electrical needs is on the rise. 90% of power plant in Indonesia still using fossil fuel. Alternative energy is needed, one of it is wind energy. Savonius wind turbine is one of many VAWT. Self starting capabilities of Savonius wind turbine is suitable to be use in city ural where the wind speed is less than 10 m/s. power that is generated by the turbine is because the difference in torque from returning blade and advancing blade. But the efisiensi of the turbine is still low. The purpose of this research is to increase the turbin performance by adding cylindrical obstacle in fornt of returning blade.
To achieve the purpose, the variation of this experiment is the location of obstacle perpendicular against the direction of incoming wind relative to blade diameter (y/D) and variation of Reynolds number. y/D variation are 0; 0,25; 0,5 and Reynolds number variation are 97000, 145000 and 178000. Stages for this experiment are: first, set the apparatus. Then record the temperature. After that turn on the blower and set the speed until it match the speed from Reynolds number 97000. After that take record of dynamic torque and static torque. Take note and repeat until the Reynolds number 178000. After data retrieval the blower is shut down and added the obstacle on position y/D = 0 then data retrieval is done using the same stage as without obstacle.
The result experiment show that the performace of Savonius wind turbine without obstacle have maximum Coefficient
iv
of Power 15,6% at Reynolds number = 97000, 13,3% at Reynolds number = 145000 and 8,5% at Reynolds number = 178000. If the cylindrical obstacle is added infornt of Returning blade the coefficient of power is increased. The most effective position is at y/D =0,5.Where at this position, compared to the conventional Savonius wind turbine, the coefficient of power of turbine with the cylindrical obstacle measured of 1,3%, 12% and 6,8% for Reynolds number = 97000, 145000 and 178000

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Savonius, Turbin angin, Coefficient of Power, Ratio y/D,
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ828 Wind turbines
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21201-(S1) Undergraduate Thesis