Redesign High Pressure Feedwater Heater (Hph2) Pltu Ujp Pelabuhan Ratu Dengan Pendekatan Thermodynamics - Heat Transfer

Kurniawan, Dicky Ari (2018) Redesign High Pressure Feedwater Heater (Hph2) Pltu Ujp Pelabuhan Ratu Dengan Pendekatan Thermodynamics - Heat Transfer. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2111645000023-Undergraduate_Theses.pdf]
Preview
Text
2111645000023-Undergraduate_Theses.pdf - Accepted Version

Download (2MB) | Preview

Abstract

High pressure heater (HPH) 2 merupakan salah satu peralatan yang menunjang kinerja feed water sistem pada siklus air dan uap di PLTU. HPH 2 berfungsi untuk memanaskan feed water dengan menggunakan ekstraksi dari turbin sebelum air tersebut dipanaskan dalam boiler sehingga kerja boiler menjadi lebih ringan dan dapat meningkatkan efisiensi pembangkit listrik. Namun HPH 2 pada PLTU UJP Jabar 2 Pelabuhan Ratu telah mengalami kebocoran sejumlah 532 tube dari 1429. Hal ini merupakan akibat off service HPH 3 dan over extraction flow masuk HPH 2. Kebocoran pada HPH 2 membuat keluaran temperature feed water pada HPH 1 yang masuk boiler menurun. Hal tersebut menyebabkan konsumsi bahan bakar pada boiler meningkat, sehingga efisiensi siklus pembangkit menurun. Oleh karena itu, perlu dilakukan proses redesign dan recalculation pada HPH 2 secara Thermodynamics-Heat Transfer agar didapatkan desain HPH 2 dengan performa yang terbaik.
Proses redesign dan recalculation dilakukan dengan menggunakan analisis termodinamika dan perpindahan panas dimana data propertis feedwater, properties uap pemanas dan properties drain digunakan sebagai inputnya. Data masukan dihitung dengan analisis termodinamika dan dimensi HPH dihitung dengan metode LMTD (Log Mean Temperature Diffirence). Variasi yang digunakan pada proses redesign adalah variasi kecepatan aliran di dalam tube dan jarak baffle untuk mendapatkan design paling optimal.
Hasil yang didapatkan dari perancangan HPH 2 adalah heat duty yang harus dipenuhi sebesar 43400 kW. HPH 2 terdiri dari 4 zona, yaitu zona Desuperheating, zona Condensing I, zona Condensing II, dan zona Subcooling. Desain baru HPH 2 adalah panjang tube zona Desuperheating 1,553 m, zona Condensing I 3,703 m, zona Condensing II 3,197 m, zona Subcooling 2,08 m. Jumlah baffle pada masing-masing zona adalah 1 buah pada zona Desuperheating, 5 buah pada zona Condensing I, 5 buah pada zona Condensing II, dan 1 buah pada zona Subcooling. Dimensi tube yang digunakan adalah diameter luar tube 16 mm, tebal tube 2,17 mm, jumlah tube 1784 buah, dan diameter dalam shell 1,39 m. Pressure drop yang terjadi pada sisi tube sebesar 0,512 bar dan pada sisi shell sebesar 0,292 bar.
========================================================================================================
High-pressure heater (HPH) 2nd is one of component to support feed water systems and steam cycles in coal fired power plant. HPH 2nd pre-heats the feed water using extracted turbine steam before being heated in boiler to increase the efficiency of power plant. HPH 2nd Pelabuhan Ratu has leakages in 532 out of 1429 tubes. It was caused by HPH 3nd out of service and then trigger over extraction flow to HPH 2nd. The leakage of HPH 2nd resulted in boiler temperatre decrease. The fuel required for boiler firing increases and efficiency of power plant decreases. So that, HPH 2nd have to be redesign and recalculated using Thermodynamics-Heat Transfer to achieve best performance.
The re-design and re-calculation process using Thermodynamics-Heat Transfer analysis using the feedwater, steam and drain properties as inputs. The input data is calculated by thermodynamic analysis and the HPH dimension is calculated by the LMTD (Log Mean Temperature Diffirence) method. Redesign variations consisted of flow velocity inside of tubes and distance of baffles to acquire optimal design.
Results of redesigning HPH 2nd is that heat duty must be 43398,816 kW. HPH 2nd consisted of 4 zones, there are Desuperheating, Condensing I, Condensing II, and Subcooling. The ammount of baffle in each zone is, 5 units in Condensing I and II, and 2 units in Subcooling. The tube dimensions is 16 mm in outer diameter of tube, and 2.17 mm in thickness, the ammount of tube is 1784, and the inner diameter of the shell is 1.39 m. The pressure drop occured inside the tube is 0.574 bar, and 0.292 bar inside the shell.

Item Type: Thesis (Undergraduate)
Additional Information: RSM 621.402 5 Kur r-1 3100018077261
Uncontrolled Keywords: High Pressure Heater, Multi Zone Heat Exchanger, Redesign
Subjects: Q Science > QC Physics > QC320 Heat transfer
T Technology > TJ Mechanical engineering and machinery
T Technology > TJ Mechanical engineering and machinery > TJ265.E23 Thermodynamics.
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21201-(S1) Undergraduate Thesis
Depositing User: Dicky Ari Kurniawan
Date Deposited: 14 Oct 2020 02:02
Last Modified: 14 Oct 2020 02:02
URI: http://repository.its.ac.id/id/eprint/55784