Sarasvati, Fatiya Indriana (2018) Penilaian Risiko Sosial pada Terminal dan Kilang Bahan Bakar Minyak, Studi Kasus: PT. Trans Pacific Petrochemical Indotama. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
04211440000111-Undergraduate_Theses.pdf - Accepted Version Download (13MB) | Preview |
Abstract
PT. Trans Pacific Petrochemical Indotama (TPPI) adalah sebuah kilang minyak yang beroperasi di Tuban, Jawa Timur. PT. TPPI mengolah kondensat menjadi berbagai macam produk seperti bahan bakar minyak. Semua proses pengolahan kondensat menjadi bahan bakar minyak khususnya solar yang terjadi di PT. TPPI perlu dilakukan penilaian risiko sosial lebih dalam untuk mengurangi tingkat risiko terjadinya bahaya seperti kebakaran. Bahaya yang ditimbulkan bisa disebabkan karena komponen-komponen yang kurang memadai. Maka dari itu dilakukanlah analisa risiko dengan metode HAZOP (Hazard and Operability) Study dengan standar BS IEC 61882. HAZOP ini dijadikan acuan untuk menentukan nilai frekuensi kegagalan dari penyebab yang terjadi. Analisa frekuensi kegagalan dilakukan dengan menentukan nilai frekuensi kegagalan dari tiap komponen yang terdapat pada sistem dengan menggunakan data dari DNV failure frequency guidance dan OGP (Oil and Gas Producers) yang kemudian di plotkan dalam FTA (Fault Tree Analysis) dan ETA (Event Tree Analysis). Penilaian dengan FTA dilakukan dengan pendekatan dari kejadian puncak (top event) hingga suatu kegagalan dasar (root cause). ETA menggunakan masukan berupa pemicu kejadian (initial event) dari nilai kejadian top event pada FTA. Initial event pada tugas akhir ini adalah oil release. Nilai frekuensi kegagalan terbesar dengan perhitungan FTA adalah sebesar 7,9E-9 sedangkan dengan perhitungan ETA adalah sebesar 4,54E-09 untuk terjadinya pool fire dan 5,61E-10 untuk terjadinya evaporation. Skenario konsekuensi yang digunakan berupa pool fire dan evaporation. Pemodelan konsekuensi menggunakan fire modelling software yang menunjukkan hasil konsekuensi berupa pool fire. Hasil konsekuensi pool fire ini adalah berupa radius intensitas panas dalam fatality level sebesar 4 kW/m2, 12,5 kW/m2, dan 37,5 kW/m2. Evaluasi risiko akan dipresentasikan dengan menggunakan F-N Curve. Risiko yang masuk ke dalam kategori unacceptable harus dilakukan mitigasi dengan metode LOPA (Layer of Protection Analysis) seperti risiko yang ditimbulkan oleh terbentuknya pool fire dengan skenario diameter lubang kebocoran sebesar 200 mm. Nilai frekuensi untuk pool fire pada storage tank area menunjukan angka sebesar 1,44E-03 di mana angka tersebut masuk ke dalam kategori unacceptable pada F-N Curve. Setelah dilakukan mitigasi dengan LOPA berupa penambahan IPL (Independent Protection Layer) berupa gas detector dan CO2 system maka nilai frekuensi menjadi 2,88E-06 yang menandahkan frekuensi tersebut telah berpindah ke daerah ALARP (As Low As Reasonably Practicable Risk).
=======================================================================================================
PT. Trans Pacific Petrochemical Indotama (TPPI) is an oil refinery operating in Tuban, East Java. PT. TPPI processes condensate into various products such as fuel oil. The process of condensate turns into fuel oil especially diesel oil that occurs in PT. TPPI needs to be examined deeper about social risk assessment to reduce the level of hazards such as fire. The hazards can be caused by inadequate components. Therefore, risk analysis is done with HAZOP (Hazard and Operability) Study method with BS standard IEC 61882. HAZOP is used as a reference to determine the value of the failure frequency of the causes that occur. The failure frequency analysis is performed by determining the failure frequency value of each component in the system using DNV failure frequency guidance and OGP (Oil and Gas Producers) data which is plotted to FTA (Tree Fault Tree Analysis) and ETA (Event Tree Analysis). FTA is done by calculating from top event to a root cause then ETA used the initial event from the top event value on the FTA. Initial event in this research is oil release. The highest value of frequency using FTA calculation is 7,9E-9 while using ETA, the value are 4,54E-09 for pool fire incident and 5,61E-10 for evaporation incident. This research used pool fire and evaporation as the consequence scenarios. The modelling of consequence uses fire modelling software that shows the consequences of pool fire. The result of this pool fire is a radius of heat intensity in fatality level of 4 kW/m2, 12,5 kW/m2, and 37,5 kW/m2. Risk evaluation will be presented using F-N Curve. Risks that categorized into unacceptable category should be mitigated by LOPA (Layer of Protection Analysis) methods such as the risk of pool fire with a leakage scenario of 200 mm. The failure frequency values for pool fire in the storage tank area show a number of 1,44E-03 where the numbers can be categorized into unacceptable category on the F-N Curve. After performing mitigation with LOPA in the form of addition some IPL (Independent Protection Layer) such as gas detector and CO2 system to the system then the failure frequency value becomes 2,88E-06 which can be categorized into ALARP (As Low As Reasonably Practicable Risk) category.
Item Type: | Thesis (Undergraduate) |
---|---|
Additional Information: | RSSP 665.774 Sar p-1 3100018077781 |
Uncontrolled Keywords: | Kilang Minyak, Penilaian Risiko Sosial, HAZOP, Fire Modelling, Mitigasi |
Subjects: | H Social Sciences > HD Industries. Land use. Labor > HD61 Risk Management T Technology > T Technology (General) > T174.5 Technology--Risk assessment. T Technology > T Technology (General) > T55 Industrial Safety T Technology > TP Chemical technology > TP343 Liquid and gaseous fuel T Technology > TP Chemical technology > TP692.5 Oil and gasoline handling and storage T Technology > TS Manufactures > TS173 Reliability of industrial products T Technology > TS Manufactures > TS174 Maintainability (Engineering) . Reliability (Engineering) |