Arif Hidayah, Mochamad (2018) Efek Ketinggian Backflow Pada Pemasangan Mikro Hidro Kinetik Di Kanal PLTU Paiton. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
04211440000029-Undergraduate_Theses.pdf - Accepted Version Download (3MB) | Preview |
Abstract
Debit yang dihasilkan pada kanal pembuangan kondenser di PLTU memiliki intensitas yang tinggi namun tidak semua dapat dimanfaatkan dengan baik. Intensitas aliran debit yang tinggi seharusnya dapat dimanfaatkan sebagai sumber energi. Salah satu energi yang sudah dikembangkan namun belum diimplementasikan secara komersial adalah Pembangkit Listrik Tenaga Mikro Hidro (PLTMH). PLTMH merupakan teknologi konversi yang mengubah energi kinetik aliran air menjadi energi listrik. Namun disisi lain ada efek yang dihasilkan saat pemasangan turbin untuk PLTMH, yaitu timbul arus balik yang mengakibatkan perbedaan ketinggian aliran pada kanal, padahal di keluaran kondenser ada persyaratan bahwa pertambahan ketinggian aliran tidak boleh bertambah lebih tinggi dari 1 m, untuk itu perlu dilakukan analisa untuk mencari sejauh mana perbedaan ketinggian aliran yang terjadi agar tidak mengganggu kinerja kondenser. Setelah dilakukan simulasi didapat hasil bahwa untuk variasi kecepatan aliran 2 m/s, 2.5 m/s, 3 m/s, 3.5 m/s, dan 4 m/s terjadi perbedaan ketinggian aliran berturut-turut sejauh 12.86 m, 43.78 m, 60.12 m 72.81 m, dan 80.06 m, dari total panjang kanal 951.68 m, maka untuk peletakan turbin dapat memenuhi persyaratan bahwa efek arus balik yang dihasilkan tidak sampai ke keluaran kondenser.
=================================================================================================================================== The discharges generated on the condenser drainage channel in the steam power plant have a high intensity but not all can be utilized properly. High intensity of debit flow should be utilized as an energy source. One of the energy that has been developed but not yet implemented commercially is Micro Hydro Power Plant (MHP). MHP is a conversion technology that converts the kinetic energy of water flow into electrical energy. But on the other hand there is an effect that is generated during turbine installation for MHP, that is reversing flow causing difference of flow height in channel, whereas in condenser output there is a requirement that the increase of flow height should not increase higher than 1 m, therefore it is necessary to analyze look for the extent of the difference in flow height that occurs so as not to disrupt the performance of the condenser. After simulation, it was found that for variations of flow velocity of 2 m/s, 2.5 m/s, 3 m/s, 3.5 m/s, and 4 m/s there were 12.86 m, 43.78 m, 60.12 m 72.81 m, and 80.06 m, of the total channel length of 951.68 m,, then for the laying of the turbine could meet the requirement that the resulting Backflow effect did not reach the condenser output.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Arus Balik, Beda Ketinggian, Kondensor, Mikro Hidro |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) > TA357 Computational fluid dynamics. Fluid Mechanics |
Divisions: | Faculty of Marine Technology (MARTECH) > Marine Engineering > 36202-(S1) Undergraduate Thesis |
Depositing User: | M. Arif Hidayah |
Date Deposited: | 28 Jun 2021 01:28 |
Last Modified: | 28 Jun 2021 01:28 |
URI: | http://repository.its.ac.id/id/eprint/56298 |
Actions (login required)
View Item |